DNTL 167 - LO1 LS3 PP Review

0.0(0)
Studied by 0 people
call kaiCall Kai
learnLearn
examPractice Test
spaced repetitionSpaced Repetition
heart puzzleMatch
flashcardsFlashcards
GameKnowt Play
Card Sorting

1/74

flashcard set

Earn XP

Description and Tags

All information taken from LO1 LS3 PP / Slide Deck

75 Terms

1
New cards

sterilization

kills all microorganisms and must be able to test for quality assurance

2
New cards

disinfection

kills some but not all microorganisms and cannot be tested for quality assurance

3
New cards

categories of re-usable client care items

critical items, semi-critical items, and non-critical items

4
New cards

critical items penetrate

soft tissue or bone

5
New cards

critical items must be

sterilized

6
New cards

what are examples of critical items

extraction forceps, explorer, and probe

7
New cards

semi-critical items touch

mucous membranes or non-intact skin

8
New cards

semi-critical items must be

sterilized

9
New cards

what is an example of a semi-critical item

mouth mirror

10
New cards

non-critical items touch

intact skin only

11
New cards

what do you do to non-critical items if contaminated during dental appointment

clean and disinfect

12
New cards

what is an example of a non-critical item

blood pressure cuff

13
New cards

for processing of critical and semi-critical items, what procedures do you follow for re-useable client care items

clean, package, sterilize, and store

14
New cards

why do we clean re-useable client care items prior to sterilization

to remove bioburden from surface of item

15
New cards

what are the 3 methods of cleaning prior to sterilization

automated instrument washers, ultrasonic cleaning, and hand scrubbing

16
New cards

what are the 3 steps of cleaning prior to sterilization

wash, rinse, and dry

17
New cards

after the 3 steps of cleaning, what must you do

inspect instruments to ensure bioburden has been removed

18
New cards

what is an automated instrument washer

a machine that washes, rinses, and dries instruments

19
New cards

automated instrument washer is the

safest and most efficient method

20
New cards

why is the automated instrument washer the safest and most efficient method

because you do not need to handle sharp contaminated instruments

21
New cards

what is a brand of an automated instrument washer

Hydrim

22
New cards

what is an ultrasonic cleaner

a machine that removes bioburden from surface by using ultrasound to agitate the liquid

23
New cards

ultrasonic cleaner is

less safe and not as efficient

24
New cards

what do you do after removing an instrument from the ultrasonic cleaner

must rinse and dry

25
New cards

how do you hand scrub

use long handle brush under running water and scrub one instrument at a time

26
New cards

hand scrubbing is

least safe and inefficient

27
New cards

why is hand scrubbing the least safe and inefficient

because DA must handle sharp contaminated instruments

28
New cards

what do you must do after hand scrubbing an instrument

must rinse and dry and be careful

29
New cards

guidelines for pre-cleaning instruments


  • instrument must be cleaned before
    they are sterilized

  • removes bioburden to allow
    sterilization to occur

  • wear utility gloves, safety glasses and
    mask

  • instruments are still contaminated
    after they have been cleaned!!

  • must visually inspect to ensure
    instruments are clean

  • be careful


30
New cards

why do we use enzymatic spray or holding solution

because dried blood and debris is very difficult to clean off
instruments

31
New cards

when do we use enzymatic spray or holding solution

to prevent bioburden from drying on instruments if cannot clean instruments immediately

32
New cards

what is an instrument cassette

metal tray with a lid

33
New cards

why do we use instrument cassettes

minimize handling of sharp instruments and keep instruments organized

34
New cards

instruments are packaged before

sterilization

35
New cards

why do we package instruments for sterilization

it allows instruments to remain sterile for storage

36
New cards

what is key to remember about packaging instruments for sterilization

do not overfill the package

37
New cards

what are the different kinds of sterilization packaging

disposable pouches, disposable wraps, and reusable wraps

38
New cards

in sterilization packaging, each product requires

specific sterilization parameters of time, temp, and pressure

39
New cards

what machine uses stream under pressure

autoclave

40
New cards

what are the 3 parameters of an autoclave (steam under pressure machine)

temperature, pressure, and time

41
New cards

what are the three different cycles of an autoclave

gravity displacement, pre-vacuum, and steam flush pressure pulse (SFPP)

42
New cards

what machine is used for flash sterilization

statim

43
New cards

statim is used for what kind of sterilization

rapid sterilization

44
New cards

when you use rapid sterilization, that means

instruments are not packaged and therefore cannot be stored

45
New cards

after putting instruments through rapid sterilization

instruments must be used immediately

46
New cards

when should you use rapid/flash sterilization

for emergency situations only

47
New cards

types of sterilization

steam under pressure, flash/rapid sterilization, dry heat sterilization, chemical vapor sterilization, and ethylene oxide sterilization

48
New cards

what type of sterilization is not acceptable in SK

chemical vapor sterilization

49
New cards

what kind of sterilization monitors are there for quality assurance

physical/mechanical monitoring, chemical monitoring, and biological indicators

50
New cards

protocols and procedures used to verify (test) physical/mechanical monitoring

read gauges or displays of each cycle to verify temp, time, and pressure parameters are met

51
New cards

physical/mechanical monitoring machine may display

an “error” messages

52
New cards

what does a correct and incorrect reading mean on a physical/mechanical monitor

correct readings do not guarantee sterilization but incorrect readings likely mean not sterile

53
New cards

what does chemical monitoring use

chemical process indicators

54
New cards

what happens to chemical process indicators

change color when exposed to sterilization process

55
New cards

chemical process indicators have how many classes

5

56
New cards

what is a class 1 process indicator (chemical monitor)

external indicator

57
New cards

where do you use a class 1 process indicator

must be used on outside of every package

58
New cards

what happens to a class 1 process indicator

changes color when package has been through sterilization cycle

59
New cards

what does a class 1 process indicator verify

that the package has been through the sterilization cycle
and prevent confusion of packages which have and have not been processed

60
New cards

what is a class 2 chemical process indicator called

bowie-dick indicator

61
New cards

what is a class 2 bowie-dick indicator used for

pre-vacuum steam sterilizers to verify air is being removed during cycle and this test must be performed every day before the first load is processed

62
New cards

what does a class 3 temperature specific indicator do

change color to verify minimum temperature is reached within the sterilization chamber

63
New cards

what chemical process indicator is not used in SK Polytech Dental Clinic

class 3 temperature specific indicator

64
New cards

class 4 multi-parameter indicators must be used

inside every package

65
New cards

what does a class 4 multi-parameter indicators do

change color to verify 2 or more sterilization parameters have entered the package

66
New cards

what does the multi-parameter mean in a class 4 indicator

it monitors 2 or more parameters

67
New cards

what does a class 5 integrating indicator do

change color to verify all 3 sterilization parameters have been met

68
New cards

where do you place a class 5 integrating indicator

inside a process challenge device

69
New cards

when do you use a class 5 integrating indicator

must be used in each load processed through the sterilizer

70
New cards

what is a PCD

process challenge device

71
New cards

what is a process challenge device (PCD)

a sterilization pouch or wrapped cassette that is used to verify the performance of a sterilizer

72
New cards

what does a process challenge device duplicate

the conditions of an instrument being processed

73
New cards

class 5 integrating indicators and biological indicators are placed

inside the PCD then processed

74
New cards

what is the highest standard test

biological indicators (BI)

75
New cards

what are biological indicators used for

to verify sterilizer is killing all microorganisms