Leakage radiation cause
loss of the tube vacuum insert
Pregnant MRT dose limit
4mSv
Whole Body Public and Students Annual Dose Limit
1mSv
Eye Lense Public and Students Annual Dose Limit
15mSv
Skin Public and Students Annual Dose Limit
50mSv
Annual MRT dose limit
50mSv (in any single year)
Whole Body Annual Dose Limit for Radiation Workers
20mSv (5 year averaged into one)
Eye Lense Annual Dose Limit for Radiation Workers
20mSv
Skin Annual Dose Limit for Radiation Workers
500mSv
Hands and Feet Annual Dose Limit for Radiation Workers
500mSv
<100kV Lead Equivalence
0.25mm
100-150kV Lead Equivalence
0.35mm
>150kV Lead Equivalence
0.5mm
Front and Back Lead Gown Pb Equivalence
front: 0.5mm
back: 0.25mm
Thyroid Shield Pb Equivalence
0.5mm
Recommened Eye Shield Pb Equivalence
0.75mm
Gloves or Gaunlets Pb Equivalence
0.25mm
Lead Acrylic screens or Movable Shields
0.5mm
Three ALARA Principles
Time
Distance
Shielding
Absorbed Dose
(Gy) the amount of dose absorbed into material
Effective Dose
(mSv) counts the degree of biological damage that may be caused by the type of ionizing radiation
Types of Radiation and Matter Interactions
Coherent scatter = low-energy photon changes direction after interaction
Photoelectric absorption = photon ejects an inner-shell electron, which the ejected electron gets absorbed; has the cascading effect
Compton scatter = photon ejects an outer-shell electron
Effects on Compton Scatter and PE Absorption as kV increase
fewer compton
many FEWER photoelectric
more transmission
Effects on Compton Scatter and PE Absorption as Tissue Atomic # increases
no change in compton
many more photoelectric
less transmission
Effects on Compton Scatter and PE Absorption as Tissue Mass Density increases
proportional increas in compton
proportional increase in photoelectric
proportional decrease in transmission
Radiosensitive Cells
Immature/non-specialized
Rapid cell division/ high reproductivity
High oxygenated tissues
Radiosensitive Tissue Rank
Most radiosensitive blood cells: Lymphocytes
Highly radiosensitive: Epithelial
Insensitive: Muscles
Insensitive: Adult nerve cells
Somatic Effects
effects on the individual irradiated
Early tissue reactions
Acute Radiation Syndrome
Hematopoietic syndrome
GI syndrome
CV syndrome
radiatio burn (erythema)
Late Effects
Cataracts
Fibrosis
Organ atrophy
Reduced fertility/ sterility
Teratogenic effects (fetus)
When is the Fetus most susceptible to radiation-induced congenital abnormalities
During Organogenesis (10-12 weeks)
Stochastic Effects
= probability depends on received dose, but the severity does not
cancer
genetic/hereditary effects
Genetic/ Non-somatic effects
effects on future generations due to the irradiation of previous generations
Gonadal doses as low as 0.1 Gy can depress the male sperm population, cause genetic effects, and may delay or suppress menstruation
CT Dose Reduction Strategies
Tube current modulation (AEC)
Iterative reconstruction
Tube voltage and scan parameter optimization
Isocentering
Mobile Radiation Safety
The radiographer must wear protective garments.
The radiographer should stand at least 2 m away from the X-ray tube and useful beam.
If possible, the radiographer should also stand at a right angle to the x-ray beam–scattering object (the patient) line.
as SID increases… energy and intensity?
no change in energy
decrease in intensity
Inverse Sqaure Law
mAs2/mAs1 = (SID2)2/(SID1)2
Dosimeter Placement for Routine Radigraphs
collar level with no PPA
Dosimeter Placement for Fluoro
outside the apron at collar level
Dosimeter Placement for IR
outside the apron at collar level
second montior for lengthy IR procedures should be placed under the apron at the waist level
Dosimeter Placement for Pregnant MRT
second monitor placed under the apron, at waist level