Single-Line Diagram (SLD)

A diagram that represents the power distribution topology of facilities such as data centers.

2
New cards

Main Breaker (MB)

The primary switch that controls the electrical supply for a facility.

3
New cards

Utility Main Breaker (UMB)

A breaker that protects the incoming utility power supply.

4
New cards

Standby Generator

An on-site backup generator that supplies secondary power controlled by a generator breaker.

5
New cards

Power Distribution Cabinet (PDC)

A cabinet that receives power from feeder breakers and distributes it to individual server racks.

6
New cards

Cascading Trip Sequence

A sequence of actions where protective breakers open in response to electrical faults, beginning with the most localized breaker.

7
New cards

Potential Transformer (PT)

A transformer that steps down system operating voltage for safe measurement.

8
New cards

Current Transformer (CT)

A transformer that samples line current and sends reduced output to monitoring relays.

9
New cards

Static UPS System

A power supply system that includes a rectifier, battery bank, inverter, and static transfer switch.

10
New cards

ANSI Device 51

An inverse-time AC overcurrent relay that trips faster with higher overcurrent levels.

11
New cards

Cascaded Control Loop

A control loop design where one controller influences another, allowing for modular design and specialized function.

12
New cards

Set Point (SP)

The desired target value for a controlled variable in a control loop.

13
New cards

Process Variable (PV)

The actual value of a measured parameter in a control loop.

14
New cards

Signal Line Convention: Solid Line

Indicates process piping containing the main process fluid.

15
New cards

Signal Line Convention: Dashed Line

Indicates electrical transmission signals.

16
New cards

ISA Tag Lettering: A

Designates an Analysis element in instrument tagging.

17
New cards

Dimension Line

Lines terminating in arrowheads indicating measurement extent in technical drawings.

18
New cards

Hidden Lines

Dashed lines that represent hidden internal edges or surfaces in engineering drawings.

19
New cards

Leader Line

A line that connects a note or dimension to a specific feature of an object.

20
New cards

Hydraulic Valve

A valve actuated by hydraulic pressure and using hydraulic signal lines.

21
New cards

Motor-Operated Valve (MOV)

A valve actuated by an electric motor, often controlled via electrical signals.

22
New cards

Decentralized Backup Power

Emergency power provided individually to racks to prevent total facility power loss.

23
New cards

Protective Breakers

Devices designed to isolate faults at the closest point to protect electrical systems.

24
New cards

Breaker Isolation

The method of protecting downstream equipment by isolating faults at the nearest breaker.

25
New cards

Arc Dimensioning

Defined by their radius (R), allowing for identification of curvatures in mechanical drawings.

26
New cards

Cascading Trip Action

A method of fault isolation where the action cascades upstream if the fault cannot be cleared.

27
New cards

Visible (Object) Lines

Thick, solid lines that define visible edges of an object in engineering drawings.

28
New cards

Pneumatic Control Valve

A valve that is actuated by compressed air and controlled through pneumatic signal lines.

29
New cards

Schematic Cross-Referencing

The matching of a contactor to its controlling coil through alphanumeric identifiers.

30
New cards

Final Control Element

Mechanical assemblies like valves that adjust flow rates or pressure in a control loop.

31
New cards

Maintenance Bypass Synchronization

The requirement for synchronized AC sources during maintenance to prevent electrical stress.

32
New cards

Differential Protective Relay (Device 87)

A relay that detects differences in currents to provide fault protection.

33
New cards

Under/Over Frequency Relay (Device 81)

A relay that trips if the facility frequency falls outside normal limits.

34
New cards

Fault Isolation

The principle of identifying and shutting down faults to maintain operational integrity.

35
New cards

Uninterruptible Power Supply (UPS)

A backup power supply system that provides emergency power when the main source fails.