Illuminance
The density of luminous flux on a surface, measured in the SI system by lux (10.76 lux=1 fc).
Foot-Candle (fc)
A unit of illuminance commonly referenced in visual inspection standards, where most visual tests require a minimum level of 100 fc.
Illuminate
To shine light on an object or examination surface.
Luminance
The ratio of a surface's luminous intensity in a given direction to a unit of projected area, where incident or reflected light is measured in candela per square meter (cd/m2).
Lux (lx)
The unit of measure for illuminance in the SI system, equivalent to lumens per square meter (lm/m2).
Photometry
The science and practice of the measurement of light or photon-emitting electromagnetic radiation.
Illuminating Engineering Society (IES) Standards
Standards that recommend 100−300 fc (1100−3200 lux) for proper examination of critical work, and 50 fc (538 lux) for less critical work.
ASME Section V Article IX(4)
A code specification that mandates an illumination requirement of at least 100 fc (1076 lux) for visual examination.
NavSea Technical Publication T9074-AS-GIB-010/271
A naval standard that specifies visual inspection requirements, including the provision of adequate lighting.
Photometer
An instrument used to measure the intensity of light at the surface of an examination item.
Photometer Calibration Interval
A requirement that photometers be calibrated every 6 months, unless prior calibration data justifies a 12-month interval; calibration must never exceed 12 months.
Lambert's Cosine Law
A physical law stating that light intensity varies inversely with the square of the distance from the source and directly with the cosine of the angle measured from the normal to the surface.
Substitution Photometry
A photometric procedure in which an unknown light source is measured in terms of an auxiliary or comparison standard.
Ratio Photometry (Relative Photometry)
The evaluation and measurement of the light output of a test lamp relative to a known reference standard.
Fluorescent Lighting (in Inspection)
A light source emitting a blue-shifted spectrum that aids in detecting specific surface flaws by enhancing or subduing certain colors and contrast.
Contrast
The ability of the human eye to perceive a difference between luminescence or color and its background.
Luminescence Contrast
The difference in light reflection between an object or flaw and its surrounding background.
Cleanliness Suit Demonstration
The requirement that an inspector equipped with a complete cleanliness suit, hood, or air mask prove inspection capability under those restrictive environmental conditions.
Direct Visual Examination
The most widely used visual examination method, conducted with the eye positioned within 24 in of the surface at an angle of 30∘ or greater.
Minimum Focusing Distance Limitation
The restriction that an inspector cannot view closer than 10 in from the surface because the human eye cannot focus properly at closer ranges.
Visual Distance Resolution Limits
The maximum spatial resolution of the eye at specific distances: approximately 0.003 in at a distance of 12 in, and approximately 0.007 in at 24 in.
Normal Visual Acuity (20/20 Vision)
The ability of the eye to resolve a spatial pattern separated by a visual angle of one minute of arc (601∘ of arc).
Retinal Visual Angle Projection
The projection where 1∘ of a scene covers about 290μm of the retina containing 123 cones, with 601∘ covering 2 cones (the minimum required to resolve an object).
Indirect Visual Examination
A visual examination technique using borescopes, fiberscopes, televisions, or mirrors, which must be demonstrated to have resolution capability equivalent to direct examination.
18% Neutral Gray Card
A standard reference target historically used in visual specifications requiring the resolution of a 321 in black line on an 18% neutral gray background.
ASME Section XI Inspection Scope
Nuclear in-service visual examination rules covering components such as pumps, valves, welds, supports, and associated material surfaces.
Specialized Visual Training Requirement
Instruction and practical training required for inspectors to properly recognize anomalies on specialized materials (such as titanium welds) and skillfully manipulate remote visual equipment.