1
New cards

what are the 3 things muscle do

strength, power, endurance

2
New cards

what is strength

greatest force that can be generated by a muscle during single max effort

3
New cards

what is power

work produced by a muscle per unit of time ([force x distance]/time)

4
New cards

what is endurance

ability to contract repeatedly against a load and resist fatigue over an extented period of time

5
New cards

what is a reason we do NMES

strength

6
New cards

what is overload

for a muscle to increase strength, it must, on a regular basis, be challenged to overcome resistances that are greater than those usually encountered

7
New cards

what is SAID

specific adaptations to imposed demands

-training should mimic the way the musculoskeletal system will be used

8
New cards

what are short term muscle adaptations to strengthening

-increase activation

-increse muscle selectivity

-increase coordination

9
New cards

what are the long term muscle adaptations to strengthening

-increase muscle CSA

-increase # contractile proteins

-strengthening of NMJ

10
New cards

what is the goal of NMES

to maximize force production while minimizing fatigue

-can do this by modifying stimulation parameters

11
New cards

what are the factors influencing muscle force production

-rate coding

-recruitment

-muscle properties: length tension and force velocity

12
New cards

what do you want to do with rate coding

-maximize force at a given recruitment level

-use frequencies at flat portion of FFR

-want to do it at a frequency on the flat part of the curve that will allow for high force production and low fatigue

13
New cards

what is true about the higher the frequency the stim is

the higher the frequency, the more fatigued they will be, and the less force they can do

14
New cards

why can't you do low frequency

won't be able to generate enought force

15
New cards

how do you decide frequency

-pick on flat line

-too high : fatigue

-too low: not enough force

-find sweet spot

16
New cards

is it necessary to blast the muscle at highest frequency possible

no

-higher the frequency, the greater the rate of fatigue

-compromise by using a frequency on the plateau phase of the FFR

17
New cards

how does recruitment influence muscle force production

increasing the number of motor units which increases force production

-function of phase charge

18
New cards

what do you wanna maximize

pulse duration and amplitude

-typiclaly 200-600us (or 400)

19
New cards

how does length tension infuluence muscle force production

to maximize force position joint in midrange near optimal length

-need to respect surgical or other precautions

20
New cards

what kind of contraction is NMES best done in

isometrically

-highest force can be produced safely

21
New cards

why don't u wanna do NMES in eccentric contraction

difficult to control force using NMES

22
New cards

why don't u wanna do NMES in concentric contraction

-timing of NMES difficult to control to end with ROM

-faster the mostion, less force is produced

23
New cards

why is isometric contraction used

-most controlled and safe

-infinite load for strengthening

-often used in painful joint conditions to minimize movement

24
New cards

why would dynamic- concentric contraction used

-promote ROM

-motor learning component

-Ecc with safety for torque limits

25
New cards

what are central factors influencing muscle force production

rate coding and recruitment

-muscle synergies

-agonist/antagonist co activation

-affective components

26
New cards

what are peripheral factors influencing muscle force production

-length tension

-force velocity

-muscle composition

-ortho injuries

-certain diseaeses

27
New cards

what is the assessment of muscle strength process

quantify 1 rep max MVIC

-dose: express NMES as % MVIC

-dose response: > % MVIC > recovery

28
New cards

what is the minimum for gains

50% MVIC of involved side

or

10% MVIC of uninvolved side

29
New cards

wha is volitional muscle strengthening

intermittent, high force contractions

30
New cards

what can both volitional activation and electrical stimulation do

can induce a rise in the amount of muscle fiber contractile protein

31
New cards

what is superimposed electrical stimulation for

activating the muscle to its full potential

32
New cards

what is the effectiveness of NMES for strengthening

-significant strength gains can be achieved in healthy muscle with an electrically augmented training program ; the intensity needs to be extremely high (>100%MVIC)

-electrical stimulation offers equivalent muscle strengtheing effects to voluntary exercise in healthy subjects ; if intensity levels parallels volitional exercise intensities

-lower loads may still help in muscle recovering from injury/surgery

most studies using subjects other than healthy male college students demonstrated greater strength gains in subjects training with NMES compared to volitional exercise alone

33
New cards

what are the principles for strengthening with NMES

-need high intensity

-need high frequency

-need rest period

-modify on/off times - 1:5

34
New cards

what can high intensity elctrical stim lead to at the knee during stance

high intensity electrical stimulation leads to more normal excursions of the knee joint during stance

35
New cards

what can lower loads still help in

lower loads may still help in muscle recovering from injury/surgery

-greater strength grains in subjects training with NMES compared to volitional exercise alone

36
New cards

what are the parameters

-frequency

-pulse width

-amplitude

-on/off times

-ramp time

37
New cards

what should the frequency be

60-80 pps

38
New cards

what should the pulse width be

400us

39
New cards

what should the amplitude be

highest tolerated

40
New cards

what should the on/off times be

1:5 ratio

41
New cards

what should the ramp time be

2 seconds

42
New cards

are there any magic parameters

NO

-set your parameters to your treatment needs

<p>NO</p><p>-set your parameters to your treatment needs</p>
43
New cards

what would you change if someone is fatiguing too quickly

decrease the frequency

-might alter force production

44
New cards

what are the characteritics of on/off time

necessary because continous stimulation of skeletal muscle results in rapid force fatigue

-both strong and sustained contractions occulude microcirculation

-on time: usually 10-15 seconds

-off times: usually 45-120 seconds

45
New cards

what is ramp on time

1-3 seconds (to ease into high force contraction)

-don't need ramp off time

-all for pt comfort

46
New cards

what dictates pt positioning

muscle positioning is an important consideration but anatomy, condition, and the surgicial procedure often dictates position

47
New cards

what do you wanna do with pt positioning

maintaing good alignment

-make pt as comfy as possible

-account for orthopedic differences

improvise with avaible equipment

-quads

-pf

48
New cards

what is the placement of electrodes

-bipolar arrangment proximal distal ends

-motor point of the muscle

-shift as necessary to elicit strongest and most uniform response

49
New cards

what is skin contact of electrodes

-self adhesive electrodes provide most uniform skin-electrode interface

-avoid wrinkles (hot spots)

-avoid cuts/scratches (shaving)

50
New cards

what is the health standard of electrodes

can re use but only for same pt

51
New cards

what is electrode size

maximize for muscle size

-too large: overflow

-too small- high current density less tolerable, also may activate small portion of muscle (crampy)

52
New cards

what is the application process

-fully describe the treatment : expected and unexpectated sensations; how you present this will affect a pts expectations /tolerance; discuss the evidence

-gain consent

-orientation and wean on perioid

-increase amplitude gradually (within or across treatments)

-give pt the control when able

-provide saftey switch

-monitor treatment

53
New cards

what is true of patient comfort

the goal is to overload the muscle, pt may need to tolerate uncomfortable levels of current

54
New cards

what is often the limiting factor to NMES

pt comfort

55
New cards

what is discomfort and pain a function of

not soley a function of nociceptor input, but are moderated by cognitive and behavioral factors

56
New cards

what do you need to consider about pts comfort

-subjects preffered coping style: information seeking vs information avoiding

-whether the stimulus causes a muscle contraction: greater force= more perceived discomfort

-whether the subject is judging the intensity of the stim

57
New cards

what can we do from cognitive behvioral aspect

identify coping strategy

-apply the appropiate distraction/education

-talk to your pt and find out what helps them

-education on effectiveness

-hand holding

-encouragement

-comfort items

etc

58
New cards

what can you do from a technical aspect to help with pt comfort

-check electrodes and skin

-should not feel intense pins/needles/stabbing/burning

-no wrinkles or pulling away of electrode

-alternative placement

-orientation and weaning period

-proper positiong- accomodations if needed

-adjust phase charge -increase or decrease pulse width

-adjust ramp time

-higher frequencies

-avoid shortened muscle positions - cramp

-time between shaving and ES

-TENS cote

-give pt control

-count down

59
New cards

what do you do when things aren't going well in general

-change electrode location

-tens clean cote

-change the waveform

-decrease pulse duration

-may need to also increase the frequency for comfort

60
New cards

what do you do when things aren't going well specific

-increase ramp time

-self trigger

-increase rest time: only if see them fatiguing drastically

61
New cards

what are the precautions

-uncontrolled hyper/hypotension

-excessive adipose tissue

-pregnancy (location dependent)

-severe osteoporosis

-impaired sensation

62
New cards

what are the contraindications

avoid NMES over the following regions

-over the the thoracic region

-pacemakers

-regions of phrenic nerve stimulators

-regions of urinary bladder stimulators

-carotids

-in the region of peripheral vascular disease

-in regions of neoplasm or infection

-trunk of pregnant pt

-close proximity to diathermy devides

-over the eyes

-skin injury/frail skin

pts who can't provide clear feedback

63
New cards

what are common ortho diagnoses where you use NMES

-ACL reconstruction

-TKA

-rotator cuff strengthening

-low back pain

-calf strengthening

64
New cards

besides orthopedic, what else doese NMES have clinical utilization in

-cerebral palsy

-complete SCI

-hemiplegic shoulder subluxation post stroke

-wrist, hand, and finger function post stroke

-critical illness and advanced disease states

-heart failrue