Rad Lab #4 Canine Thoracic Sedation

0.0(0)
Studied by 0 people
call kaiCall Kai
learnLearn
examPractice Test
spaced repetitionSpaced Repetition
heart puzzleMatch
flashcardsFlashcards
GameKnowt Play
Card Sorting

1/12

encourage image

There's no tags or description

Looks like no tags are added yet.

13 Terms

1
New cards
<p><strong>LEFT LATERAL THORAX RADIOGRAPH:</strong> (pretend)</p><p>→ beam center?</p><p>→ measurement?</p><p>→ anatomical limit?</p><p>→ positioning? (4 things)</p>

LEFT LATERAL THORAX RADIOGRAPH: (pretend)

→ beam center?

→ measurement?

→ anatomical limit?

→ positioning? (4 things)

BEAM CENTER: over heart 5th intercostal space (ribs 5-6)

MEASUREMENT: caudal aspect of scapula (shoulder blades)

ANATOMICAL LIMIT: 1cm b4 1st rib - 1cm after last rib (10th rib)

POSITIONING:

  • ribs superimposed

  • foam sponge used to elevate sternum

  • forelimbs pulled towards head

  • hindlimb pulled caudally


2
New cards
<p><strong>When should you take a lateral thorax?</strong></p>

When should you take a lateral thorax?

→ taken during INSPIRATION to max contrast

→ allows space btw cardiac silhouette (outline of heart) and diagram so they don’t overlap

3
New cards

What exposure factors and additional positioning are used for L lateral thorax radiographs?

→ long-scale contrast (long list of grey) = ⬇mAs +⬆kVp

→ use⬆mAs w the shortest exposure time possible

→ place head towards cathode side to prevent (heel effect)

4
New cards

kVp

K very powerful = determines the power of x ray penetration

5
New cards

mAs

Might allow some = determines the amount/quantity of photons released (want a good amount for a noise free x-ray but not too high where there’s unneeded exposure)

  • Too little mAs → more noise (graininess).

  • Too much mAs → unnecessary radiation exposure.


6
New cards
<p><strong>VENTRODORSAL THORAX RADIOGRAPH:</strong></p><p>→ beam center?</p><p>→ measurement?</p><p>→ anatomical limit?</p><p>→ positioning? (3 things)</p>

VENTRODORSAL THORAX RADIOGRAPH:

→ beam center?

→ measurement?

→ anatomical limit?

→ positioning? (3 things)

BEAM CENTER: over heart

MEASUREMENT: caudal border of scapula (shoulder blades)

ANATOMICAL LIMIT: thoracic inlet - 1st lumbar vertebra

POSITIONING:

  • sternum superimposed over spine

  • front limbs extended cranially

  • hindlimb in n position


7
New cards

When should you take a VD thorax?

→ taken during INSPIRATION

8
New cards

What exposure factors and additional positioning are used for VD thorax radiographs?

→ keep patient as straight as possible (via troughs, sandbags)

→ b sides of rib cage should appear =

TIP: imagine a straight line from nose to caudal midline

9
New cards
<p><strong>LATERAL &amp; VD ABDOMINAL RADIOGRAPH:</strong></p><p>→ beam center?</p><p>→ measurement?</p><p>→ anatomical limit?</p><p>→ positioning</p>

LATERAL & VD ABDOMINAL RADIOGRAPH:

→ beam center?

→ measurement?

→ anatomical limit?

→ positioning

BEAM CENTER: caudal aspect of 13th rib (umbilicus)

MEASUREMENT: caudal aspect of the 13th rib for b L & VD

ANATOMICAL LIMIT: diaphragm - acetabulum

POSITIONING:

  • b sides of rib cage should be =

  • sternum and spine are superimposed

  • limbs are extended cranially and caudally


10
New cards

When should you take a L & VD abdominal?

→ taken during EXPIRATION

11
New cards

What exposure factors and rules used for VD abdominal radiograph?

  • fast for better visualization of abdominal contents

  • diaphragm should be positioned cranially

  • prevents the diaphragm from compressing abdominal contents


12
New cards

Fill In Blanks:

→ pulse and resp r taken q _____ mins

→ temp taken q _____ mins

→ notify teacher if HR < ___ bpm

5 mins

15 mins

60 bpm

13
New cards

→ review records duty

→ Eye Tests (fluorescein staining, schirmer tear test, tonometry)

tonometer

→ IV infusion

→ Blood draw