Contrast

the visible difference between any two selected areas of brightness levels within the displayed image

2
New cards

What is the function of contrast

to make detail visible

3
New cards

Contast is determined primarily by...

the precessing algorithm, the matrix size, & the subject contrast of the patient

4
New cards

processing algorithm

The mathematical codes used by the software to produce a desired image appearance

5
New cards

High Contrast

short scale more black and white

6
New cards

Low Contrast

long scale with lots of greys

7
New cards

Compared to IRE or Brightness, Contrast is...

more subjective as it is affected by an individuals preference

8
New cards

What amount of contrast is desired?

depends on the anatomic composition of the part being radiographed

9
New cards

contrast is evaluated best when...

IR exposure or brightness is adequate

10
New cards

Radiographic Contrast is influenced by:

kilovoltage (kVp) or penetrating power

11
New cards

High kVp results in...

less absorption, more transmission, and fewer IR exposure differences (low contrast)

-increases penetration power of beam

12
New cards

kVp and Contrast relationship

Inverse

high kVp means low contrast, low kVp means high contrast

13
New cards

Low kVp results in...

more absorption, less transmission, and less iRE (High Contrast)

-decreases penetration power of beam

14
New cards

kVp _________ quanlity of the beam and ____________ quantity of photons

increases; increases

15
New cards

Higher kilovoltage does what to scatter?

increases the amount of scatter produces which will decrease radiographic contrast

16
New cards

Scatter radiation

provides no useful information only unwanted IR exposure of fog

17
New cards

Why are IR's with CR and DR extremely sensitive to scatter and secondary radiation compared to film screen radiography?

because DR has a higher dynamic range and is able to detect more greys

18
New cards

What do grids do for contrast?

they clean up the scatter that would interact with the IR, meaning less fog produces increasing the contrast on the image

19
New cards

Higher ratio grid

greater efficiency at cleaning up scatter meaning greater contrast

20
New cards

Higher frequency grid

less efficiency ?

21
New cards

Beam filtration and contrast relationship

indirect

as filtration increases, contrast decreases because it makes the beam more homogenous creating less differences in the tissua absorption, so every shade of gray is closer together

22
New cards

Beam filtration __________ quality and ___________ quantity

increases; decreases

23
New cards

Contrast Media

changes the absorption characteristics of the tissues, by increasing or decreasing the attenuation of the beam

-used when imaging anatomic tissues that have low subject contrast

24
New cards

Positive contrast media does what to attenuation?

increases it while improving overall contrast

25
New cards

Negative contrast media does what to attenuation?

decreases it while improving overall contrast

26
New cards

Beam Restriction and Contrast Relationship

direct

the decrease in collimation means the larger the field size, meaning it will irradiate more tissue and with more matter youll have more scatter which decreses contrast on the image (more matter more scatter)

27
New cards

Beam Restriction Devices

changes in field size affect the amount of tissue irradiated and more matter = more scatter which will decrease contrast

28
New cards

As OID is increcreased, it creates...

an air gap between the pt and IR that will absorb scatter radiation before it reaches the IR resulting in less scatter on the image and greater contrast

29
New cards

OID and contrast relationship

direct

-increase OID, scatter misses radiograph and improves contrast

30
New cards

What has no affect on contrast?

mAs and SID

31
New cards

How does SID have no affect on contrast?

when SID is changed the ratio of change of the brightness pixels is maintained resulting in no differences of adjacent IR exposures, thus no change in contrast

32
New cards

Changes in SID does not change the ________ of the beam

quality

33
New cards

Compression and Contrast relationship

direct

-the greater the compression the higher the contras because less matter, less scatter

34
New cards

Compression

radiographer places a band around the patient to compress and bring everything closer to the IR, less matter, so there will be less scatter which will improve contrast on image

35
New cards

In what modality is compression used?

Mammography to have less scatter and higher contrast