d’Arsonval Meter Movement
Basic DC current-measuring movement used in analogue ammeters, voltmeters + ohmmeters
Pointer deflection is proportional to current through the coil
Current in the coil creates a magnetic field that interacts with the permanent magnet, causing the coil/pointer to move
Hairspring opposes movement and returns the pointer to zero when current stops
PMMC Meter
Permanent-Magnet Moving-Coil (PMMC) is based on the d’Arsonval movement
More current → stronger coil magnetic field → greater pointer movement
Iron core concentrates the magnetic field
Curved pole pieces help the turning force increase steadily with current
DC Ammeter
Low-resistance shunt connected in parallel with the meter movement
Allows the ammeter to measure currents above its normal full-scale value
Shunt carries most of the current; only a small amount passes through the meter movement
External shunts may be used in high-current circuits, e.g. generator feeder lines
Ammeter Shunt
Low-resistance shunt connected in parallel with the meter movement
Allows the ammeter to measure currents above its normal full-scale value
Shunt carries most of the current; only a small amount passes through the meter movement
External shunts may be used in high-current circuits, e.g. generator feeder lines
Shunt Resistance
Meter + shunt are in parallel → same voltage drop
Formula: RSH = (IM × RM) / ISH
Shunt resistance must be accurate for correct measurement + meter protectionMeter + shunt are in parallel → same voltage drop
Formula: RSH = (IM × RM) / ISH
Shunt resistance must be accurate for correct measurement + meter protection
Ammeter Range Selection
Always start on the highest range → prevents meter damage
Reduce the range until a clear/accurate reading is obtained
Prefer a reading around the middle of the scale
Never select a range below the current being measured
Voltmeter
Measures voltage between two points
High-resistance instrument connected in parallel
Analogue → pointer movement; digital → numerical display
Voltmeter Multiplier Resistor
Multiplier resistor connected in series with the meter movement
Extends the voltage range
Limits current through the movement to its maximum full-scale current
Voltmeter Loading
Connecting a voltmeter can change the circuit voltage being measured
This causes loading error
Voltmeter should have high resistance compared with the circuit to minimise loading
Voltmeter Safety
Always connect in parallel
Start on the highest range
De-energise + discharge before connecting/disconnecting
DC voltmeter → observe correct polarity
Never use a DC voltmeter to measure AC voltage
d’Arsonval AC Reading
d’Arsonval movement operates on DC
To measure AC → AC must first be rectified into pulsating DC
Rectification can be half-wave or full-wave
Full-wave bridge rectifier is commonly used and gives higher sensitivity than half-wave
d’Arsonval AC Reading
Meter movement responds to the average value of the rectified AC
Average value = 63.7% of peak
AC meter scale is calibrated to display the effective (RMS) value
Therefore an AC meter gives an incorrect reading if used to measure DC
Ohmmeter
Measures resistance (Ω)
Has its own internal battery to produce the current needed for measurement
Never connect an ohmmeter to an energised circuit → external voltage causes incorrect readings and can damage the meter
Analogue Ohmmeter Scale
The scale is basically backwards compared with volts/amps:
0 Ω → maximum current → maximum pointer deflection
∞ Ω → no current → minimum pointer deflection
Therefore 0 Ω is on the right, ∞ is on the left
Scale is uneven because of the relationship R = E/I
Zeroing An Ohmmeter
Before measuring:
Short the test leads together
Adjust the zero control/rheostat
Pointer should read 0 Ω
This compensates for changes in the internal battery voltage as it ages.
Multi-Range Ohmmeter
Multiply the scale reading by the selected range.
Example:
20 Ω on scale × R × 100 = 2000 Ω = 2 kΩ
Higher ranges generally give less accurate readings, especially toward the left side of the scale.
Safety Ohmmeter
Designed for resistance testing of explosive devices/volatile environments
Examples → squibs, igniters, detonators + flares
Uses a very small test current
Typical current limited to 0.5 mA
Insulation Tester/Megohmmeter
Measures very high resistance, in megohms (MΩ)
Used to check the integrity of electrical insulation
Unlike a normal ohmmeter, it applies a high DC test voltage — up to 1000 V DC
Weak insulation → more leakage current → lower insulation resistance
Megohmmeter Safety & Use
Disconnect system power
Disconnect wires being tested at both ends
Use only the test voltage specified in maintenance data — e.g. 125, 250, 500 or 1000 V
Too high a test voltage can damage the insulation
Keep away from flammable materials/fuel vapour
After testing, keep leads connected for a few seconds to discharge stored capacitive charge
Multimeter
A multimeter = multiple meters in one. It can measure:
AC/DC current
AC/DC voltage
Resistance (Ω)
Analogue Multimeter
Uses a moving needle
Good for seeing changes/fluctuations
Useful for testing rheostats/potentiometers
Loads the circuit more → useful for finding some high-resistance joints
Has Zero Ω Adjust when measuring resistance
Typical sensitivity: 20,000 Ω/V DC, 1,000 Ω/V AC
Digital (DMM/DVOM) Multimeter
Displays a number
No parallax error
More common because it’s accurate, compact, easy to use, auto-ranging + higher sensitivity
Can be used in any position
Check calibration before use
Clap Meter
Measures current by clamping around the conductor, so you don’t need to directly connect it into the circuit.
Current-transformer clamp → AC only
Hall-effect clamp → AC + DC
General Meter Safety
Most important:
Check meter is calibrated
Inspect test leads for damage
Check lead continuity
Use correct input jacks
Select correct function
If unsure of range → start high and work down
Fused current inputs help protect you + equipment
Logic Probe
Used for troubleshooting digital logic circuits.
Can quickly identify:
HIGH
LOW
OPEN
PULSING
Basic probe:
Red = HIGH
Green = LOW
Both dim = high-frequency pulse train
Oscilloscope
Think of it as a voltmeter that draws the signal.
Shows:
Voltage/amplitude
Frequency/time
Waveform shape
For a sine/cosine wave:
VRMS = 0.707 × Vpeak
Decade Box
A box containing precision resistors, capacitors or inductors that you can dial to a desired value.
Main use → load substitution
Each dial works in multiples of 10.
Signal Generator
Produces a known AC test signal with the desired:
Frequency
Amplitude
Modulation
Used to test, align and troubleshoot electronic equipment such as transmitters/receivers.
You feed the signal into the circuit, then follow it using a voltmeter or oscilloscope.
What does a Time-Domain Reflectometer (TDR) do?
Measures cable length + locates faults
Sends a pulse down cable → fault causes reflection
Time of reflection = distance to fault
Shape/size of reflection = nature of fault
What is a NAV/COMM test set used for?
Tests/simulates aircraft navigation + communication systems
Main systems: VOR, ILS (LOC/G/S), Marker Beacon + COM
Can test things like frequency, transmitter power, receiver sensitivity + SWR
What is an ATC transponder test set used for?
Tests ATC transponders
Can test them on the bench or installed in the aircraftTests ATC transponders
Can test them on the bench or installed in the aircraft
What does a DME Test set do
Simulates DME range + velocity signals
DME measures slant-range distance between aircraft and ground station
Distance determined from round-trip signal time
What is a pitot-static test set used for?
Tests aircraft pitot + static systems
Checks altitude, airspeed + vertical speed
Can perform leak tests
Can test ADC operation + transponder at simulated altitude
What are the key precautions when performing a pitot/static leak test?
Follow the AMM procedure and specified pressure-change rate
Pressure → pitot/pressure ports
Suction → static ports
Never use your mouth/lungs
Ensure pitot heat is OFF + electrically isolated
Check ports/holes are not blocked
Use only approved static-port blocking devices
Never exceed the AMM pressure increase/decrease rate → can damage sensing elements
What is a (Fuel Quantity Indication) FQI test set used for?
Tests capacitance-type fuel quantity systems
Measures/substitutes capacitance
Measures insulation resistance
Can simulate the compensator
What is a loop resistance tester used for?
Measures resistance in cable loops
High resistance can indicate corrosion
Corrective action → clean junctions, secure loose connections or replace cable
What are the key requirements when fitting grommets?
Material must suit the environment/temperature
TFE → 260°C
Silicon/rubber → 120°C
Nylon → 85°C
Cut nylon grommet at 45°, with cut at top
What is the maximum number of connections allowed on one terminal-board stud?
Maximum 4 lugs, OR
3 lugs + 1 bus
What are the key requirements for electrical connectors?
Inspect for contamination, corrosion, bent/pushed-back/worn pins
Connectors must have positive locking to prevent loosening from vibration
Threaded connector without positive lock → wire lock in tightening direction
What are the key precautions when handling ESD-sensitive avionics equipment?
Do not touch component/connector pins or sockets
Aircraft grounded + power removed before removal
Touch equipment metal case before disconnecting to equalise electrostatic potential
Immediately fit conductive covers/caps to disconnected plugs
During installation, touch connector outer shells together/aircraft earth to equalise potential
What must be checked when installing an LRU into an avionics rack?
Inspect connector for bent pins, contamination + corrosion
Ensure LRU is flush + centralised
Gently engage support pins + connector keys before fully pushing in
Secure correctly in the rack
Key pins/keyways prevent the wrong LRU being fitted
How is a cockpit Dzus fastener operated?
Unlock → 90° anticlockwise
Do not force past 90° → can damage fastener
Lock → push down and rotate 90°
What is the purpose of preventative maintenance?
To prevent failures before they occur
Includes inspection, adjustment, lubrication + replacement
What is the difference between ATE and BITE?
ATE (Automated Test Equipment) → LRU is removed from aircraft and tested using external automated equipment
BITE (Built-In Test Equipment) → test capability is built into the component/system
BITE can range from simple go/no-go tests to recording faults and providing repair instructions
What is a troubleshooting flow chart used for?
Provides a logical testing + diagnosis path
Each test result directs you to the next test or conclusion
Works using “if–then” decisions
What does No Fault Found (NFF) mean in avionics maintenance?
LRU is removed for a suspected fault but tests serviceable in the workshop
Majority of NFFs are caused by poor troubleshooting techniques
Wastes time, labour + costs
What are the main troubleshooting methods?
Heuristic → use a rule-of-thumb, e.g. check a commonly failing component first
Shotgunning → randomly replace LRUs until fault disappears → inefficient, expensive + causes NFFs
Half-split → test approximately halfway through the signal path to eliminate half the possible fault area
How does the half-split troubleshooting method work?
Trace the entire signal path
Test at the halfway point
Signal correct → move toward the output/end
Signal incorrect → move toward the source
Continue until fault is isolated
What should you do before extensive troubleshooting?
Confirm the fault actually exists
Understand the system + normal operation
Use diagrams/manuals
Troubleshoot logically, not by trial-and-error/shotgunning
Don’t assume the first abnormal component found is the actual cause
What are the important troubleshooting terms?
CFS → group of possible faults that could explain the symptoms
Hypothesis → assumed cause that must be proven or disproven by testing
Psychic blindness → assuming a new fault is the same as a previous fault
Tunnel vision → focusing on one suspected cause and ignoring evidence against it
Test-induced failure → the testing itself creates a new fault
What is the key process for isolating an avionics fault?
Confirm the reported fault with a functional test first
Use other serviceable outputs to eliminate common components
Use half-split testing to progressively narrow down the fault
Confirm the faulty component before replacing it
Why can re-racking an LRU fix a fault?
Removing + refitting the LRU re-makes the pin/socket connections
Can correct a poor electrical connection
May prevent a serviceable LRU being unnecessarily sent for repair
How can a duplicate system help confirm a faulty component?
Swap a known serviceable component into the faulty system and retest
Be aware of software/configuration requirements
A faulty LRU could potentially damage the serviceable system
Document work + test all systems potentially affected by disconnected connectors
What tests are normally performed on aircraft electrical circuits?
Bonding
Continuity
Insulation resistance
Functional testing
What is the difference between bonding and grounding?
Bonding → electrically connects conducting objects together
Grounding → connects a conducting object to aircraft structure/earth for current return
Helps protect against lightning, static, shock + EMI/RF interference
What are the key aircraft bonding resistance limits?
General electrical bond → ≤ 0.1 Ω
RF equipment bond → ≤ 0.0025 Ω (2.5 mΩ)
Aircraft extremities / component to main earth → ≤ 0.05 Ω
Always follow manufacturer limits if specified
What are the key bonding inspection requirements?
Bond must be secure + corrosion-free
No self-tapping screws
Attach bonds directly to basic aircraft structure
Moving-part bond braid → maximum 12 in
Restore protective finish after testing
What does a continuity test verify?
Electrical link exists between specified points
Resistance of the link is within limits
Near 0 Ω → good connection
∞ / very high resistance → open or poor connection
Circuit must be unpowered
Check wiring diagram for alternate paths that could give false readings
What are the typical minimum insulation-resistance values for aircraft wiring?
Single conductor → 5 MΩ minimum
Bundled wiring → 2 MΩ minimum
High resistance = good insulation
Low resistance = poor insulation
What are the key precautions when insulation-testing wiring with a Megger?
Disconnect both ends of cable before testing
Meggers may be 250 V, 500 V or 1000 V
Leads apart → should indicate high resistance
Leads shorted → should indicate 0 Ω
Centre conductor → one lead
Aircraft ground/shield → other lead
If reading moves toward 0 Ω, stop immediately
What are the key requirements for solderless terminations and splices?
Copper wire → copper termination
Aluminium wire → aluminium termination
Prevents dissimilar-metal corrosion
Permanent aircraft wire splices must be environment-resistant sealed splices
Class II tools, lugs + splices should not be used on aircraft
What do aircraft crimping tools do?
Crimp the barrel to the conductor
Simultaneously crimp the insulation grip to the wire insulation
Can be hand or power operated
Must follow the aircraft/equipment manufacturer’s instructions
What are the key requirements for crimping small copper wires?
Small copper wires → 26–10 AWG
Use MIL-DTL-22520 qualified tools
Approved hand tools have a self-locking ratchet → prevents opening until crimp is complete
Never disassemble the ratchet mechanism
What wire sizes do the terminal lug colours identify?
Red → 22–18 AWG
Blue → 16–14 AWG
Yellow → 12–10 AWG
: How is a crimping tool checked for serviceability?
Check with a Go/No-Go gauge
Gauge before each series of crimping operations
Out-of-tolerance tool → repair or replace
If gauge unavailable → millivolt drop + tensile strength test
What are the key requirements for crimping large copper wires?
Large copper wires → 8–4/0 AWG
Can use manual or power/hydraulic crimping tools
Select correct die for terminal + wire size
Disconnect power tool from pressure source before changing dies
Never exceed tool’s rated capacity
Inspect completed crimp after operation
Why does aluminium aircraft wire require special termination procedures?
Lighter than copper, but softer
Bending causes work hardening → becomes brittle → strands can break
Forms a high-resistance oxide film when exposed to air
Never use aluminium wire with nicked/broken strands
What are the key requirements when terminating aluminium wire?
Use SAE AS70991 aluminium terminal lugs only
Lugs marked “AL” + applicable wire size
Inspection hole checks correct wire insertion
Do not remove inspection plug until after crimping
Replace plug after inspection
Petroleum-based abrasive compound removes oxide during crimping and prevents it reforming
Use MS25441 installation tool
Lugs are not pre-insulated → protect afterward with transparent tubing or heat-shrink sleeve
What are the key requirements for splicing copper aircraft wires?
Small wire: 26–10 AWG → MIL-S-81824 environmental permanent splices
Approved tools → M22520/5 or M22520/10
Crimp both ends of splice
Stripped wire must be visible through inspection hole before and after crimping
Large wire: 8–4/0 AWG → uninsulated splice
Large splice → insulate afterward with heat-shrink or transparent flexible sleeving
What are the key EWIS rules for locating wire splices?
Keep splices to a minimum
Avoid areas of extreme vibration
Normally maximum 1 splice per wire segment between disconnect points
Splices in bundles → stagger them
Normally no splice within 12 in. of a termination device
Bundle splices require engineering approval and should allow periodic inspection
Use correct crimping tool
What should be checked when inspecting an EWIS splice?
Crimp centred + aligned with barrel
Barrel and insulation not cracked
Correct environmental seal
No overheating
Wires fully inserted/butted against stop
Wire ends visible through inspection holes
What are the key MIL-DTL-22520 crimping tools and their uses?
M22520/1-01 → contact barrel sizes 12–20
M22520/2-01 → contact barrel sizes 20–28
M22520/4-01 → coaxial contacts, creates circular crimp
M22520/7-01 → contact barrel sizes 16–22
Hand tools have ratchet cycle control → will not release until crimp is complete
How are contact crimping tools checked before use?
Check with Go/No-Go gauge before each series of crimping operations
Go gauge must pass
No-Go gauge must NOT pass
If either check fails → do not use tool; return for repair
Never crimp down on gauge pins
Do not disassemble or adjust crimp tools yourself
What is the difference between front-release and rear-release connector contacts?
Front release: tool inserted from front → contact pushed out the rear
Rear release: tool inserted from rear → releases retention clip → contact pulled out the rear
Both types are inserted from the rear
Rear-release connectors almost always have a blue band
What AWG sizes do contact insertion/removal tool colours typically identify?
Yellow → AWG 12
Blue → AWG 16
Red → AWG 20
These colours are not the same as crimper colour coding
How do you remember which end of a rear-release tool to use?
White/light = removal = OUT
Coloured/dark = insertion = IN
Memory: “Cave — dark is IN, light is OUT.”
What are key precautions when removing connector contacts?
Front-release → avoid excessive canting of tool → can bend contacts
Rear-release → tool goes over wire from rear, releases contact, then tool + wire pulled together
Use correct tool for the contact/AWG size
What are the key parts and characteristics of coaxial cable?
Used mainly for RF signals
Centre conductor → carries signal
Dielectric → insulates conductors + maintains their position/constant capacitance
Outer conductor/shield → usually copper braid
Outer jacket → protects against moisture and abrasion
Most aircraft coax studied → 50 Ω characteristic impedance
What are the main coaxial connector types and differences?
BNC → bayonet, quick connect/disconnect, small cable, ≤ 500 V peak
HN → threaded, high voltage up to 5000 V
N → general-purpose, threaded
C → bayonet, quick connect/disconnect
TNC → like BNC but threaded; positive coupling under vibration
SC → like C but threaded
What are the key precautions when assembling coaxial cable?
Do not nick shield or centre conductor
Avoid breaking shield strands
Correct contact:
Male → plug
Female → jack
Contact must butt flush against dielectric after solder cools
If not flush → remake joint
Manufacturer/vendor instructions take precedence
How does a TDR locate faults in coaxial cable?
Sends an electrical pulse down cable
Fault/impedance change causes a reflection (echo)
Echo location helps locate fault
Echo shape and direction provide information about the fault
How does AWG relate to wire size?
Higher AWG number = smaller wire
Current capacity depends on cross-sectional area
What are the key aluminium wire size rules?
Replacing copper → aluminium 2 sizes larger
Aluminium smaller than No. 6 not permitted
What key wiring limits should you remember?
Support intervals → max 24 in.
Identification intervals → max 15 in.
Splices → normally at least 10 ft apart
What are the key wire-bundle limits?
Max bundle → 75 wires or 2 in. diameter, whichever is smaller
Normal bend radius → 10 × largest wire/cable diameter
If suitably supported → 3 × diameter
Thermocouple wire → 20 × diameter
RF/coax cable → 6 × diameter
What are the key cable-clamp requirements?
Clamp/support spacing → max 24 in.
Clamp snugly without pinching/crushing
Tying does not replace proper clamping
RF/coax must not be distorted by clamps
What separation limits are important?
Combustible fluid/oxygen lines → aim for 6 in. or more
Never closer than 0.5 in. to plumbing
Control cables → minimum 3 in., otherwise use mechanical guards
Never support wiring from flammable-fluid or oxygen plumbing
What are the key rules for wiring inside conduit?
Wire bundle ≤ 80% of conduit internal diameter
No ties or splices inside conduit
When must self-clinching cable straps NOT be used?
Bundles containing coaxial cable
Above 85°C
High-vibration areas
Outside fuselage / wheel wellsBundles containing coaxial cable
What are the main EWIS installation requirements?
Correct component for its intended function
Installed within its specified limitations
Must function correctly
Minimise mechanical strain
Protect wiring from overload/overheating
Protect against moisture where required
Why must EWIS be adequately separated?
Prevent mechanical interference/chafing
Prevent electrical interference (EMI)
Prevent one EWIS failure affecting another system
Separation by distance or equivalent barrier
What is the key requirement for EWIS circuit protection?
Correct type and rating of protective device/circuit breaker
Must protect wire/cable from overcurrent
Prevent fire and smoke hazards
What are the key rules when EWIS becomes contaminated?
Stop contamination source first
Keep contaminated area to a minimum
Use applicable cleaning procedure
Unknown accidental contamination → do NOT use solvents
Dust/powder → vacuum
Basic cleaning materials pH >11 are prohibited
Clean top → bottom, periphery → centre
Cloth → clean, dry, lint-free
Put solvent onto cloth, never cloth into solvent
What does flux do during soldering?
Removes oxide/tarnish
Prevents further oxide forming while heated
Allows solder to wet and penetrate the metal
Flux melts before the solder
What is the difference between soft and hard solder?
Soft solder → melts below 370°C
General aircraft electrical wiring → 60% tin / 40% lead (60/40)
Hard solder → silver alloy; greater strength/higher temperatures
Hard solder may be used for thermocouple connections
Not used on printed circuits
What is special about 63/37 tin-lead solder?
63% tin / 37% lead
Eutectic → changes directly from solid to liquid
Melts completely at 183°C
No pasty/plastic range
What indicates a good solder joint?
Solder should wet the surface
Forms a smooth, uniform, unbroken, adherent film
Smaller dihedral angle = better wetting
0–20° = excellent
90–180° = unacceptable
Which flux is used for aircraft electrical/electronic soft soldering?
Use R (rosin) or RMA (rosin mildly activated)
Never acid flux on electronic devices → corrosive + electrically conductive
Clean flux residue after soldering to prevent corrosion/contamination
What solvent is mainly used for aircraft/electronic soldering?
Isopropyl alcohol (IPA)
Removes flux residue, oils, salts and contaminants
Initial cleaning mixture → 3 parts IPA : 1 part de-ionised/demineralised water
What are the key soldering safety precautions?
Solvents are flammable → keep away from heat/ignition
Avoid breathing flux/solvent fumes → adequate ventilation
Use minimum solvent necessary
Hot iron → always return to holder/stand
Wear appropriate PPE
Turn soldering iron off/disconnect when unattended
What are the main soldering heat-application methods?
Soldering iron → normal aircraft electrical wiring
Resistance soldering → current heats the work; useful for small/congested areas
Torch soldering → high heat, e.g. silver soldering; not suitable for small parts
Dip soldering → connections dipped in molten solder; used for printed circuits