What is the name of the process the IC makes to determine if lives can be saved without unnecessary risks to firefighters?

Risk-benefit analysis

2
New cards

In the simplest terms, what type of operational strategy indicates that no one is entering an IDLH environment?

Defensive strategy

3
New cards

What type of attack is made by firefighters directing the water stream toward the ceiling or banking off walls to cool the room?

Indirect

4
New cards

When making an indirect fire attack from an interior position, firefighters should remain outside the fire compartment due to:

Creation of a large volume of steam

5
New cards

What attack strategy combines cooling the hot gas layer by moving the nozzle from the area overhead to the floor in a T, Z, or rotational pattern?

Combination

6
New cards

What type of attack uses an exterior fire attack through a ventilation opening to help a fire transition from vent limited conditions to fuel limited conditions?

Transitional

7
New cards

Sprinkler systems support the flow of sprinklers based on the:

Hazard being protected

8
New cards

When should the occupancies with automatic sprinklers, FDC, and their closest hydrants be identified?

During preincident planning

9
New cards

When supplying a fire sprinkler system, D/O should charge the FDC:

When the IC gives the order

10
New cards

A sprinkler systems FDC may consist of a:

Siamese valve

11
New cards

When flowing to a commercial sprinkler system with a multistage pump, set the transfer valve to the:

Parallel (volume) position

12
New cards

According to NFPA 13E, unless otherwise posted, the general guideline is to supply a sprinkler system with ___ into the FDC

150 psi (1050 kPa)

13
New cards

According to NFPA 13E, a residential sprinkler system should be pressurized to:

No more than water main pressure

14
New cards

A standpipe system may consist of a single vertical pipe known as a:

Riser

15
New cards

Wen supplying a standpipe system, hydraulic calculations for flows exceeding 350 gpm (1400 L/min) should include the following pressure loss in the standpipe:

25 psi (175 kPa)

16
New cards

A D/O can encounter a standpipe system with pressure-regulating devices in:

High-rise buildings

17
New cards

When operating hose lines from a standpipe, the D/O should add ___ for each floor above the FDC due to elevation

5 psi (35kPa)

18
New cards

If an FDC has a frozen swivel, fire personnel can use a double male coupling with a:

Double female coupling

19
New cards

If an individual hose valve on an upper floor fails, personnel can use:

A hose valve on the next floor down

20
New cards

In what situation might an aerial device be used as a standpipe to supply hose lines?

When the fire is higher than the reach of the aerial device

21
New cards

What should the D/O do if the pump does not develop pressure?

Ensure that the pump is properly engaged

22
New cards

Relay pumping is used when:

The water source is remote from the scene

23
New cards

The closed relay method of relay pumping involves:

Hose lines from a water source and between each pumper in the relay

24
New cards

The open relay method of relay pumping involves:

Folding drop tanks at the intake of each pumper

25
New cards

This type of valve is located on an intake relief valve to vent air from the hose before it travels down the line

Bleeder

26
New cards

During relay pumping, what are the types of hose lines that may be connected to different pumpers using a discharge manifold?

Large and medium diameter hose

27
New cards

What is the effect of increasing the discharge pressure above 150 psi (1005 kPa) in relay pumping operations?

It does not necessarily increase the volume of water through the system

28
New cards

When relay pumping, the D/O should maintain a residual pressure at the next pumper in the relay of:

20-50 psi (140-210 kPa)

29
New cards

A relay pumping operation begins with the largest capacity pumper working:

From the water source

30
New cards

When operating in a relay, apparatus equipped with pressure governors should be set in the ___ mode when acting as the attack pumper

Pressure

31
New cards

Apparatus equipped with pressure governors should be set in the ___ mode when working as a relay pumper

RPM

32
New cards

For relay pumpers equipped with an adjustable intake relief valve, the valve should be set to ___ above the static pressure of the water system or discharge pressure of the previous pumper in the relay

10 psi (70 kPa)

33
New cards

When the need for relay pumping has ended, the operation should be discontinued starting from the:

Fire scene

34
New cards

Fire pumpers placed in tandem are used to:

Increase pressure to the attack pumper

35
New cards

In tandem pumping operations, the distance between apparatus may be up to:

300 ft (90m)

36
New cards

This valve is used on a hydrant, and its use resembles a tandem pumping operation

Hydrant assist

37
New cards

Pumps supplying a relay operation or a master stream require the use of a ___ setting of the transfer valve

Parallel

38
New cards

During relay pumping, if the master intake gauge falls below 20 psi (140 kPa), increasing the throttle:

May cause the pump to cavitate

39
New cards

During tandem pumping operations, the D/O can follow several methods for preventing pump overheating, including:

Establishing a continuous minimum flow of water

40
New cards

In dual pumping operations:

One hydrant supplies two fire pumps

41
New cards

A hydrant used for dual pumping should have a flow greater than:

1000 gpm (4000 L/min)