Methods of Studying Cells and Microscopy

0.0(0)
Studied by 0 people
call kaiCall Kai
learnLearn
examPractice Test
spaced repetitionSpaced Repetition
heart puzzleMatch
flashcardsFlashcards
GameKnowt Play
Card Sorting

1/23

flashcard set

Earn XP

Description and Tags

Comprehensive practice flashcards covering microscopy principles, resolution, magnification calculations, cell fractionation, ultracentrifugation, TEM, SEM, and eyepiece graticule calibration.

24 Terms

1
New cards

What is the formula used to calculate the magnification of an object under a microscope?

magnification=size of imagesize of real object\text{magnification} = \frac{\text{size of image}}{\text{size of real object}}

2
New cards

What are the equivalent values in metres (m\text{m}) for one micrometre (μm\mu\text{m}) and one nanometre (nm\text{nm})?

One micrometre (μm\mu\text{m}) is equivalent to 10−6 m10^{-6}\,\text{m}, and one nanometre (nm\text{nm}) is equivalent to 10−9 m10^{-9}\,\text{m}.

3
New cards

An object measuring 100 nm100\,\text{nm} in length appears 10 mm10\,\text{mm} long in a photograph. What is its magnification?

Converting 10 mm10\,\text{mm} to nanometres gives 10 000 000 nm10\,000\,000\,\text{nm}. The magnification is 10 000 000 nm100 nm=×100 000\frac{10\,000\,000\,\text{nm}}{100\,\text{nm}} = \times 100\,000 (or 10510^5).

4
New cards

How is the resolution, or resolving power, of a microscope defined?

The minimum distance apart that two objects can be in order for them to appear as separate items.

5
New cards

What is the limit of resolution of a standard light microscope, and what causes this limitation?

The limit of resolution is about 0.2 μm0.2\,\mu\text{m}, which is caused by the relatively long wavelength of light rays.

6
New cards

Why does increasing magnification beyond a microscope's limit of resolution fail to reveal more detail?

Beyond the limit of resolution, increasing magnification cannot increase clarity; the object will appear larger but will simply be more blurred.

7
New cards

What is cell fractionation?

The process where cells are broken up and the different organelles they contain are separated out.

8
New cards

Why must the solution used before cell fractionation be cold, buffered, and of the same water potential as the tissue?

It must be cold to reduce enzyme activity that might break down organelles; buffered so that pH does not fluctuate (which could alter organelle structure or affect enzyme functioning); and of the same water potential to prevent organelles bursting or shrinking due to osmotic gain or loss of water.

9
New cards

What occurs during the homogenation stage of cell fractionation?

Cells are broken up by a homogeniser (blender) to release the organelles, and the resulting fluid (homogenate) is filtered to remove any complete cells and large pieces of debris.

10
New cards

During ultracentrifugation of animal cells, in what order are nuclei, mitochondria, and lysosomes separated as spin speed increases?

Nuclei sediment first at a low speed (e.g., 1000 revolutions min−11000\,\text{revolutions min}^{-1}), mitochondria sediment next at a medium speed (e.g., 3500 revolutions min−13500\,\text{revolutions min}^{-1}), and lysosomes sediment last at a high speed (e.g., 16 500 revolutions min−116\,500\,\text{revolutions min}^{-1}).

11
New cards

Given that chloroplasts have a greater mass than mitochondria but a smaller mass than nuclei, how can a sample rich in chloroplasts be isolated using ultracentrifugation?

Homogenise and filter the plant tissue, spin the filtrate at a low speed to sediment the heavier nuclei into a pellet, pour off the supernatant, and spin the supernatant at an intermediate speed (faster than for nuclei, but slower than for mitochondria) to pellet the chloroplasts.

12
New cards

What are the two main advantages of an electron microscope compared to a light microscope?

The electron beam has a very short wavelength, giving it a high resolving power (0.1 nm0.1\,\text{nm}), and because electrons are negatively charged, the beam can be focused using electromagnets.

13
New cards

Why must a near-vacuum be created inside the chamber of an electron microscope?

Because electrons are absorbed or deflected by the molecules in air, which would prevent the microscope from working effectively.

14
New cards

How do the focusing elements and image receivers differ between a compound light microscope and a transmission electron microscope?

A light microscope uses glass condenser, objective, and eyepiece lenses to project an image to the human eye, whereas a transmission electron microscope uses magnetic condenser, magnetic objective, and magnetic projector electromagnets to project an image onto a fluorescent screen.

15
New cards

How does a transmission electron microscope (TEM) form an image?

An electron beam passes through a thin section of the specimen; parts of the specimen that absorb electrons appear dark, while parts that allow electrons to pass through appear bright, forming an image on a screen that can be photographed.

16
New cards

Why can the theoretical resolving power of 0.1 nm0.1\,\text{nm} in a TEM not always be achieved in practice?

Difficulties preparing the specimen limit the achievable resolution, and the higher energy electron beam required may destroy the specimen.

17
New cards

What is an artefact in electron microscopy?

A structural detail that results from the way the specimen was prepared and appears on the finished photomicrograph, but is not part of the natural specimen.

18
New cards

How does a scanning electron microscope (SEM) produce an image of a specimen?

It directs an electron beam onto the surface of the specimen from above and scans back and forth in a regular pattern; the scattered electrons and secondary electrons produced are analysed by a computer to build a 3-D image.

19
New cards

What is the resolving power of a basic scanning electron microscope (SEM), and how does its specimen preparation differ from that of a TEM?

A basic SEM has a resolving power of around 20 nm20\,\text{nm}, and specimens do not need to be extremely thin because electrons do not penetrate through the specimen.

20
New cards

What is an eyepiece graticule and why must it be calibrated before measuring specimen size?

It is a glass disc placed in the microscope eyepiece with an etched scale (typically 10 mm10\,\text{mm} long divided into 100 sub-divisions); it must be calibrated because each objective lens magnifies to a different degree.

21
New cards

What is a stage micrometer and what are the dimensions of its scale?

A special microscope slide used to calibrate an eyepiece graticule, typically having a scale that is 2 mm2\,\text{mm} long with smallest sub-divisions of 0.01 mm0.01\,\text{mm} (10 μm10\,\mu\text{m}).

22
New cards

If 10 units10\,\text{units} on a stage micrometer (10 μm10\,\mu\text{m} per unit) equal 40 units40\,\text{units} on an eyepiece graticule, what is the value of one graticule unit?

One micrometer unit equals 4 units4\,\text{units} on the graticule (40÷10=440 \div 10 = 4). Since one micrometer unit is 10 μm10\,\mu\text{m}, each graticule unit equals 10 μm÷4=2.5 μm10\,\mu\text{m} \div 4 = 2.5\,\mu\text{m}.

23
New cards

If an objective lens magnifying ×40\times 40 gives a calibration of 25 μm25\,\mu\text{m} per graticule unit, what is the calibration for an objective lens magnifying ×400\times 400?

Since the magnification is 10 times greater, each graticule unit is equivalent to 25 μm÷10=2.5 μm25\,\mu\text{m} \div 10 = 2.5\,\mu\text{m}.

24
New cards

A line drawn across a cell structure on a photomicrograph measures 23 mm23\,\text{mm} and represents an actual size of 5 μm5\,\mu\text{m}. What is the linear magnification?

Converting 23 mm23\,\text{mm} to micrometres gives 23 000 μm23\,000\,\mu\text{m}. The magnification is 23 000 μm5 μm=4600 times\frac{23\,000\,\mu\text{m}}{5\,\mu\text{m}} = 4600\text{ times}.