1/23
Comprehensive practice flashcards covering microscopy principles, resolution, magnification calculations, cell fractionation, ultracentrifugation, TEM, SEM, and eyepiece graticule calibration.
What is the formula used to calculate the magnification of an object under a microscope?
magnification=size of real objectsize of image
What are the equivalent values in metres (m) for one micrometre (μm) and one nanometre (nm)?
One micrometre (μm) is equivalent to 10−6m, and one nanometre (nm) is equivalent to 10−9m.
An object measuring 100nm in length appears 10mm long in a photograph. What is its magnification?
Converting 10mm to nanometres gives 10000000nm. The magnification is 100nm10000000nm=×100000 (or 105).
How is the resolution, or resolving power, of a microscope defined?
The minimum distance apart that two objects can be in order for them to appear as separate items.
What is the limit of resolution of a standard light microscope, and what causes this limitation?
The limit of resolution is about 0.2μm, which is caused by the relatively long wavelength of light rays.
Why does increasing magnification beyond a microscope's limit of resolution fail to reveal more detail?
Beyond the limit of resolution, increasing magnification cannot increase clarity; the object will appear larger but will simply be more blurred.
What is cell fractionation?
The process where cells are broken up and the different organelles they contain are separated out.
Why must the solution used before cell fractionation be cold, buffered, and of the same water potential as the tissue?
It must be cold to reduce enzyme activity that might break down organelles; buffered so that pH does not fluctuate (which could alter organelle structure or affect enzyme functioning); and of the same water potential to prevent organelles bursting or shrinking due to osmotic gain or loss of water.
What occurs during the homogenation stage of cell fractionation?
Cells are broken up by a homogeniser (blender) to release the organelles, and the resulting fluid (homogenate) is filtered to remove any complete cells and large pieces of debris.
During ultracentrifugation of animal cells, in what order are nuclei, mitochondria, and lysosomes separated as spin speed increases?
Nuclei sediment first at a low speed (e.g., 1000revolutions min−1), mitochondria sediment next at a medium speed (e.g., 3500revolutions min−1), and lysosomes sediment last at a high speed (e.g., 16500revolutions min−1).
Given that chloroplasts have a greater mass than mitochondria but a smaller mass than nuclei, how can a sample rich in chloroplasts be isolated using ultracentrifugation?
Homogenise and filter the plant tissue, spin the filtrate at a low speed to sediment the heavier nuclei into a pellet, pour off the supernatant, and spin the supernatant at an intermediate speed (faster than for nuclei, but slower than for mitochondria) to pellet the chloroplasts.
What are the two main advantages of an electron microscope compared to a light microscope?
The electron beam has a very short wavelength, giving it a high resolving power (0.1nm), and because electrons are negatively charged, the beam can be focused using electromagnets.
Why must a near-vacuum be created inside the chamber of an electron microscope?
Because electrons are absorbed or deflected by the molecules in air, which would prevent the microscope from working effectively.
How do the focusing elements and image receivers differ between a compound light microscope and a transmission electron microscope?
A light microscope uses glass condenser, objective, and eyepiece lenses to project an image to the human eye, whereas a transmission electron microscope uses magnetic condenser, magnetic objective, and magnetic projector electromagnets to project an image onto a fluorescent screen.
How does a transmission electron microscope (TEM) form an image?
An electron beam passes through a thin section of the specimen; parts of the specimen that absorb electrons appear dark, while parts that allow electrons to pass through appear bright, forming an image on a screen that can be photographed.
Why can the theoretical resolving power of 0.1nm in a TEM not always be achieved in practice?
Difficulties preparing the specimen limit the achievable resolution, and the higher energy electron beam required may destroy the specimen.
What is an artefact in electron microscopy?
A structural detail that results from the way the specimen was prepared and appears on the finished photomicrograph, but is not part of the natural specimen.
How does a scanning electron microscope (SEM) produce an image of a specimen?
It directs an electron beam onto the surface of the specimen from above and scans back and forth in a regular pattern; the scattered electrons and secondary electrons produced are analysed by a computer to build a 3-D image.
What is the resolving power of a basic scanning electron microscope (SEM), and how does its specimen preparation differ from that of a TEM?
A basic SEM has a resolving power of around 20nm, and specimens do not need to be extremely thin because electrons do not penetrate through the specimen.
What is an eyepiece graticule and why must it be calibrated before measuring specimen size?
It is a glass disc placed in the microscope eyepiece with an etched scale (typically 10mm long divided into 100 sub-divisions); it must be calibrated because each objective lens magnifies to a different degree.
What is a stage micrometer and what are the dimensions of its scale?
A special microscope slide used to calibrate an eyepiece graticule, typically having a scale that is 2mm long with smallest sub-divisions of 0.01mm (10μm).
If 10units on a stage micrometer (10μm per unit) equal 40units on an eyepiece graticule, what is the value of one graticule unit?
One micrometer unit equals 4units on the graticule (40÷10=4). Since one micrometer unit is 10μm, each graticule unit equals 10μm÷4=2.5μm.
If an objective lens magnifying ×40 gives a calibration of 25μm per graticule unit, what is the calibration for an objective lens magnifying ×400?
Since the magnification is 10 times greater, each graticule unit is equivalent to 25μm÷10=2.5μm.
A line drawn across a cell structure on a photomicrograph measures 23mm and represents an actual size of 5μm. What is the linear magnification?
Converting 23mm to micrometres gives 23000μm. The magnification is 5μm23000μm=4600 times.