1
New cards

Incentive Spirometry is also known as...

Sustained maximal inspiration (SMI)*

2
New cards

what are the 2 reasons we use incentive spirometry?

-treat micro-atelectasis

-prevent atelectasis

3
New cards

Intermittent Positive Pressure Breathing (IPPB) is used to treat...

atelectasis

4
New cards

this device can provide early detection of atelectasis or pneumonia by observing decreasing inspiratory capacity levels

incentive spirometer

5
New cards

name 3 hazards of incentive spirometry

-Hyperinflation

-Pneumothorax

-Potential vagal reflex

6
New cards

Name 2 indications for Intermittent Positive Pressure Breathing (IPPB)

-Medication administration to patients who cannot breathe deep

-Postoperative atelectasis

7
New cards

name 4 hazards of IPPB

-Excessive Oxygenation

-Decreased Cardiac Output

-Increased Intracranial Pressure

-Gastric Distention

8
New cards

name 4 contraindications for IPPB

-Pneumothorax

-Nausea

-Increased Intracranial Pressure

-Pulmonary Hemorrhage

9
New cards

the IPPB pressure knob controls the...

Tidal Volume

10
New cards

pressure and volume are ____________ related

directly

11
New cards

what is the initial pressure setting on IPPB?

between 5-7

12
New cards

on IPPB, we set the pressure to achieve AT LEAST _________ times a normal tidal volume

2-3

13
New cards

what does the IPPB Flow knob control?

I-time

14
New cards

Flow and I-time are _____________ related

inversely

15
New cards

what is the initial sensitivity setting on IPPB?

15 (-2cmH20)

16
New cards

the lower the sensitivity, the ___________ it is for the patient to trigger inspiration

harder

17
New cards

if IPPB sensitivity is set too ___________, the machine may start self cycling

high

18
New cards

the apnea knob controls the __________

E-time

19
New cards

Apnea and E-time are ___________ related

directly

20
New cards

what is the initial apnea setting?

7 o'clock position

21
New cards

when the air mix knob is pushed in, what percent of the gas is oxygen?

100%

22
New cards

when the air mix knob is pulled out, room air is entrained. What percent of the gas is oxygen?

40-80%

23
New cards

what is the initial flow rate setting?

20

24
New cards

if the patient cannot cycle the IPPB machine off, how would you troubleshoot?

check for leaks

25
New cards

2 lung expansion therapies used to prevent and treat atelectasis in patients who cannot perform incentive spirometry

EzPAP & AccuPAP