Module 4: Radiation Protection

0.0(0)
Studied by 0 people
call kaiCall Kai
learnLearn
examPractice Test
spaced repetitionSpaced Repetition
heart puzzleMatch
flashcardsFlashcards
GameKnowt Play
Card Sorting

1/36

encourage image

There's no tags or description

Looks like no tags are added yet.

37 Terms

1
New cards

why does protection matter?

ALARA and the patient-benefit balance

2
New cards

How is exposure controlled?

time, distance, shielding

3
New cards

how equipment and room design reduce:

unnecessary dose

4
New cards

Radiation protection is a ____, not a single device

system

5
New cards

protection must address the__

patient, personnel, and the public

6
New cards

Good practice of radiation protection means;

diagnostic information with the least reasonable exposure

7
New cards

health physics deals with:

research, teaching, and operational aspects of radiation safety

8
New cards

health physics includes:

occupational protection and minimizing dose to the population

9
New cards

Health physics developed historically from ____, but is central to modern medical imaging

nuclear work

10
New cards

Health physics

  • Two recurring concepts:


ALARA and the linear nonthreshold model (no dose is safe)

11
New cards

ALARA stands for

as low as reasonably achievable

12
New cards

ALARA does not mean no radiation, it means-

no unnecessary radiation

13
New cards

ALARA

  • The radiographer controls many ____ choices


practical dose-reduction choices

14
New cards

Cardinal principles of protection

Time, distance, shielding

15
New cards

Time

  • Dose is ___ related to exposure time


directly

  • double the time, double the dose


16
New cards

Exposure Time formula?

Exposure = exposure rate x time

17
New cards

What can you do to reduce time in fluoro

Use pulsed fluoro, intermittent operation, last-image hold, and 5 minute timer

18
New cards

Time may also affect image ____

quality (motion)

19
New cards

Distance

  • Exposure ____ rapidly as distance increases


decreases

  • inverse square law


20
New cards

Distance

  • In diagnostic imaging, the ___ is often the major source of scatter


patient

21
New cards

Distance

  • For the patient distance is ____ 40’’, 72’’ , for technologists its a ____


fixed, variable

22
New cards

Approximate exposure rate, at normal position, at waist height is ____

3 mGy/hr

23
New cards

Shielding

  • What are common shielding materials?


lead and concrete

24
New cards

Shielding

  • Half-value layer (HVL):


thickness that reduces ingensity to 50%

25
New cards

Shielding

  • Tenth-value layer (TVL):


thickness that reduces intensity to 10%

26
New cards

Shielding

  • 1 TVL is approximately how many HVLs


3.3 HVLs

27
New cards

Shielding works best when combined with:

time and distance

28
New cards

Occupational Dose Monitoring

  • Most Occupational Dose in diagnostic imaging is associated with:


fluoroscopy

29
New cards

Occupational Dose Monitoring

  • lead aprons greatly reduce:


trunk dose, nearly zero

30
New cards

Occupational Dose Monitoring

  • Effective dose (EfD) estimates:


whole-body risk from partial-body exposure

  • weighted average of dose of each organ and tissue


31
New cards

Occupational Dose Monitoring

  • Effective dose to entire body is estimated to be ____ of dosimeter reading


10%

32
New cards

Occupational Dose Monitoring

  • Example; collar dosimeter recieves 1 mSv, what is the effective dose to whole body?


100 uSv

33
New cards

NCRP Report No. 102 was published ??

published in 1989 by the national council on radiation protection and measurements (NCRP)

34
New cards

NCRP Report No. 102 - what is it?

  • Foundational guidance for the design, performance, and safe use of medical radiation equipment

  • addresses equipment protection, radiation surveys, personnel monitoring, diagnostic imaging, and pt/staff protection


35
New cards

Built-in protection: The x-ray unit

  • ____ housing limits leakage and off-focus radiation


lead-lined tube housing

36
New cards

Built-in protection: The x-ray unit

  • leakage radiation measured at a distance of 1 meter from the x-ray source cannot exceed ____ when the tube is operated at its highest voltage at the highest current that allows continuous operation


1 mGy/hr

37
New cards

Built-in protection: The x-ray unit

  • control panel is:


located behind a protective barrier with an observation window