why does protection matter?
ALARA and the patient-benefit balance
How is exposure controlled?
time, distance, shielding
how equipment and room design reduce:
unnecessary dose
Radiation protection is a ____, not a single device
system
protection must address the__
patient, personnel, and the public
Good practice of radiation protection means;
diagnostic information with the least reasonable exposure
health physics deals with:
research, teaching, and operational aspects of radiation safety
health physics includes:
occupational protection and minimizing dose to the population
Health physics developed historically from ____, but is central to modern medical imaging
nuclear work
Health physics
Two recurring concepts:
ALARA and the linear nonthreshold model (no dose is safe)
ALARA stands for
as low as reasonably achievable
ALARA does not mean no radiation, it means-
no unnecessary radiation
ALARA
The radiographer controls many ____ choices
practical dose-reduction choices
Cardinal principles of protection
Time, distance, shielding
Time
Dose is ___ related to exposure time
directly
double the time, double the dose
Exposure Time formula?
Exposure = exposure rate x time
What can you do to reduce time in fluoro
Use pulsed fluoro, intermittent operation, last-image hold, and 5 minute timer
Time may also affect image ____
quality (motion)
Distance
Exposure ____ rapidly as distance increases
decreases
inverse square law
Distance
In diagnostic imaging, the ___ is often the major source of scatter
patient
Distance
For the patient distance is ____ 40’’, 72’’ , for technologists its a ____
fixed, variable
Approximate exposure rate, at normal position, at waist height is ____
3 mGy/hr
Shielding
What are common shielding materials?
lead and concrete
Shielding
Half-value layer (HVL):
thickness that reduces ingensity to 50%
Shielding
Tenth-value layer (TVL):
thickness that reduces intensity to 10%
Shielding
1 TVL is approximately how many HVLs
3.3 HVLs
Shielding works best when combined with:
time and distance
Occupational Dose Monitoring
Most Occupational Dose in diagnostic imaging is associated with:
fluoroscopy
Occupational Dose Monitoring
lead aprons greatly reduce:
trunk dose, nearly zero
Occupational Dose Monitoring
Effective dose (EfD) estimates:
whole-body risk from partial-body exposure
weighted average of dose of each organ and tissue
Occupational Dose Monitoring
Effective dose to entire body is estimated to be ____ of dosimeter reading
10%
Occupational Dose Monitoring
Example; collar dosimeter recieves 1 mSv, what is the effective dose to whole body?
100 uSv
NCRP Report No. 102 was published ??
published in 1989 by the national council on radiation protection and measurements (NCRP)
NCRP Report No. 102 - what is it?
Foundational guidance for the design, performance, and safe use of medical radiation equipment
addresses equipment protection, radiation surveys, personnel monitoring, diagnostic imaging, and pt/staff protection
Built-in protection: The x-ray unit
____ housing limits leakage and off-focus radiation
lead-lined tube housing
Built-in protection: The x-ray unit
leakage radiation measured at a distance of 1 meter from the x-ray source cannot exceed ____ when the tube is operated at its highest voltage at the highest current that allows continuous operation
1 mGy/hr
Built-in protection: The x-ray unit
control panel is:
located behind a protective barrier with an observation window