1/15
Vocabulary flashcards covering safety rules, equipment handling (micropipettors and microcentrifuges), agarose gel electrophoresis, and UV spectrophotometric DNA quantification from Lab 1 of BIO 2010 General Genetics.
Micropipettor
A precision laboratory instrument designed to measure and transfer small liquid volumes (<1ml), with calibrated scales marked in microliters (μl) ranging between 0.5μl and 1000μl.
P10 Micropipettor
An infrequently used micropipettor calibrated for dispensing liquid volumes within the range of 0.5μl to 10μl.
P20 Micropipettor
A micropipettor model calibrated for dispensing liquid volumes within the range of 2μl to 20μl.
P200 Micropipettor
A micropipettor model calibrated for dispensing liquid volumes within the range of 20μl to 200μl.
P1000 Micropipettor
A micropipettor model calibrated for dispensing liquid volumes within the range of 200μl to 1000μl.
First Stopping Point (Plunger)
The point of initial resistance felt when depressing the micropipettor plunger; it is used to draw the exact calibrated volume of liquid into the disposable tip upon slow release.
Second Stopping Point (Plunger)
The point reached by depressing the micropipettor plunger beyond the initial resistance stop; it is used to completely expel and discharge all remaining liquid from the tip.
Centrifugation
A separation technique that separates suspended particles from a solution according to their size, shape, density, medium viscosity, and rotor speed by spinning them at defined speeds.
Centrifugal Force
The outward force generated upon suspended particles when a centrifuge rotor spins about a central axis, accelerating the natural process of sedimentation.

Sedimentation Rate
The rate at which a particle settles during centrifugation; at a fixed centrifugal force and liquid viscosity, it is directly proportional to particle size (molecular weight) and the density difference between the particle and the solution.
Agarose Gel Electrophoresis
A laboratory method that separates DNA fragments according to their size by applying an electric current that drives the fragments through a sieving polysaccharide matrix.
Restriction Enzymes
Enzymes used to cleave or digest a larger DNA molecule into specific smaller fragments prior to diagnostic visualization via agarose gel electrophoresis.
Optimum Nucleic Acid Absorption Wavelength
260nm, the specific ultraviolet wavelength at which DNA and RNA exhibit maximal absorbance due to the heterocyclic rings of their nitrogenous bases.
dsDNA Absorbance Equivalence Factor
The standard conversion factor where 1unit of absorbance at 260nm corresponds to a concentration of 50ng/μl of double-stranded DNA (dsDNA).
DNA Concentration Formula
The equation used in spectrophotometry: [DNA]=Absorbance(260nm)×50ng/μl×dilution factor.
DNA Purity Ratio
The ratio of absorbance readings given by Absorbance(280nm)Absorbance(260nm), utilized to assess the purity of a DNA sample against protein or chemical contamination.