1
New cards

Spectroscopy

the study of the absorption and emission of light and other radiation by matter

2
New cards

Spectrometry

the measurement of the interactions between light and matter, and the reactions and measurements of radiation intensity and wavelength

3
New cards

Spectrophotometry

the quantitative measurement of the reflection or transmission properties of a material as a function of wavelength

4
New cards

TRUE

[T/F] Particles are moved from their normal room temperature state, or ground state, to one or more higher-energy excited states

5
New cards

FALSE (electromagnetic energy)

[T/F] Mechanical energy is transferred to the atoms, ions or molecules of the sample when radiation passes through a layer of solid, liquid or gas

6
New cards

Electromagnetic radiation

produced when excited particles (atoms, ions or molecules) relax to lower energy levels by giving up their excess energy as photons

7
New cards

Photons

electromagnetic radiation is produced when excited particles (atoms, ions or molecules) relax to lower energy levels by giving up their excess energy as ___

8
New cards

Emission

reciprocal of absorption

9
New cards

TRUE

[T/F] In emission, particle starts from the excited state to the ground state by releasing its energy

10
New cards

4 Causes of Emission

  1. Bombardment w/ electrons or elementary particles, which leads to emission of X-rays

  2. Exposure to an electric current or intense heat source producing UV, visible or IR radiation

  3. Irradiation with a beam of electromagnetic radiation

  4. An exothermic chemical rxn that produces chemiluminescence


11
New cards

gamma rays

electrons:x-ray : nucleus:___

12
New cards

electrons

___:x-ray : nucleus:gamma rays

13
New cards

TRUE

[T/F] Electrons from the outer shell have higher energy states than those in the inner shell

14
New cards

FALSE (repulsion; the electron will move away until it is removed/released from the atom)

[T/F] Interaction of electron and another electron will result to attraction

15
New cards

FALSE (inner shell)

[T/F] Rule in placing electrons: always fill in the outer shells first

16
New cards

TRUE

[T/F] Exposure of the particle with electromagnetic radiation will also result to emission of radiation

17
New cards

Scattering of Radiation

electromagnetic radiation is transmitted at all angles from the original path

18
New cards

FALSE (smaller)

[T/F] Scattering of radiation is usually observed when atomic or molecular particles are slightly bigger relative to the wavelength of the radiation

19
New cards

Diffraction of Radiation

a parallel beam of radiation is bent as it passes by a sharp barrier or through a narrow opening

20
New cards

Electromagnetic Radiation

Type of energy that is commonly known as light

21
New cards

Electric

radiation oscillating vertically

22
New cards

Magnetic

radiation oscillating horizontally

23
New cards
  • Sinusoidal Wave Model

  • Particle Model


2 EM models

24
New cards

Sinusoidal Wave Model

[EM models] Wavelength, frequency, velocity, and amplitude

25
New cards

Particle Model

[EM models] Viewed as a stream of discrete particles, or wave packets, of energy called photons

26
New cards

Sinusoidal Wave Model

more accepted EM model

27
New cards

amplitude (A)

[Parts of a Wave] Distance of the vector to the highest point of the wave

28
New cards

period (p)

[Parts of a Wave] The time in seconds where 2 maxima or 2 minima propagate

  • expressed in sec


29
New cards

frequency (v)

[Parts of a Wave] Number of oscillation (one wave propagation) per second

  • expressed in Hz, /sec, CPS


30
New cards

wavelength (λ)

[Parts of a Wave] Distance between 2 maxima (Peak or Crest) or 2 minima (Trough)

  • expressed in nm, mm, cm, Å


31
New cards

wavenumber

[Parts of a Wave] Reciprocal of wavelength

  • expressed in /nm, /mm, /cm, /Å


32
New cards

3.00 × 108 m/s

speed of light (c)

33
New cards

6.626 × 10-34 J•s

Planck’s constant

34
New cards

10 Å

[Conversion] 1 nm = ___ Å

35
New cards

107 ergs

[Conversion] 1 J = ___ ergs

36
New cards

1.6 × 10-19 J

[Conversion] 1 eV = ___ J

37
New cards

7.9512 x 10-19 J

[Calculation] A light of wavelength 250 nm strikes a metal surface. Calculate the energy in J of the incident photon

38
New cards

828.25 nm

[Calculation] Calculate the wavelength (in nm) of the light that strikes a solution given that the energy of the incident photon is 1.5 eV

39
New cards

Quantum Theory

theory that states that the energy of a photon absorbed or emitted during a transition from one molecular energy level to another is given by the equation: E = hv

40
New cards

Ultraviolet-visible (UV-Vis) spectroscopy

an electronic transition spectroscopic technique in which the interaction between incident radiation and electrons results in the promotion of one or more of the outer or the bonding electrons from a ground state into a higher-energy state

41
New cards

Absorbance

difference between the incident and transmitted light

42
New cards

200-380 nm

UV light range (nm)

43
New cards

380-700 nm

visible light range (nm)

44
New cards

200-700 nm

UV-vis spectrum (nm)

45
New cards

TRUE (also, longer wavelength = lower energy)

[T/F] The more loosely held the electrons are within the bonds of the molecule, the longer the wavelength of the radiation absorbed.

46
New cards

Chromophores

extended system of double bonds that causes absorption of light at UV-visible region

47
New cards

Chromophores

The functional group needed to analyze using UV-Vis; only they can absorb light in this region

48
New cards

Alizarin (red)

[natural organic pigments] from madder root

49
New cards

Kermesic/Carminic acid (red-pink)

[natural organic pigments] from the insect Coccus cacti

50
New cards

Indigo

[natural organic pigments] from Isatis tinctoria (woad)

51
New cards

Punicin / Tyrian purple

[natural organic pigments] from mollusks of the genus Murex

52
New cards

β-carotene (orange)

[natural organic pigments] from carrots

53
New cards

crocetin (yellow-brown)

[natural organic pigments] from saffron

54
New cards
  1. continuum source

  2. mono-/polychromator

  3. sampling area

  4. detector


4 parts of instrumentation

55
New cards

Collimator

Gathers and directs the light into the Monochromator

56
New cards

Monochromator

Disperses the light into its component wavelengths

57
New cards
  • continuous

  • pulsed


2 types of light source

58
New cards

visible (continuous)

[uv/vis light source] tungsten halogen

59
New cards

uv (continuous)

[uv/vis light source] deuterium arc

60
New cards

uv & vis (continuous)

[uv/vis light source] xenon arc

61
New cards

uv & vis (pulsed)

[uv/vis light source] xenon flash lamp

62
New cards

Monochromator

used to disperse (separate) the light into its constituent wavelengths, which are further selected by the slit (wavelength selector)

63
New cards

TRUE (opposite for polychromators)

[T/F] Monochromators allow the dispersion of light before it passes through the sample

64
New cards

Absorbance spectrum

spectrum of absorbances using a spectrum of radiation; absorbances at different wavelengths

65
New cards

Amax

peak of absorbance spectrum; wavelength of maximum (highest) absorbance


66
New cards

TRUE

[T/F] Monochromators are rotated so that a range of wavelengths is passed through the sample as the instrument scans across the spectrum

67
New cards

Polychromator

have multiple exit slits, each of which allows a different wavelength to pass through it

68
New cards
  • based on material (quartz, plastic, optical glass)

  • based on size (1cm, 2cm, 4cm)


cuvette types

69
New cards

uv & vis

[cuvette use] quartz

70
New cards

vis

[cuvette use] plastic

71
New cards

vis

[cuvette use] optical glass

72
New cards
  • fiber-optic-based immersion probes

  • flow cells

  • automated sample changers

  • micro-well plate configurations


4 uv-vis arrangements

73
New cards

fiber-optic-based immersion probes

[uv-vis arrangements]

  • The sample is not inside the instrument. 

  • Probe the sample at its original container.


74
New cards

flow cells

[uv-vis arrangements]

  • or “flow through cell”

  • Has an inlet and outlet where the sample flows

  • The drug can be analyzed at different points or time intervals since the sample is flowing.


75
New cards

automated sample changers

[uv-vis arrangements]

  • Can analyze multiple samples by automating rotations.


76
New cards

micro-well plate configurations

[uv-vis arrangements]

  • for micro-volume and high-throughput applications

  • high-throughput = analyze a very large number of samples or data points rapidly


77
New cards

Detector

converts analytical signal → electrical signal

78
New cards

Photoelectric detectors

generate an electric current (electrical signal) that is directly proportional to the intensity of the radiant energy (analytical signal) incident upon them

79
New cards

Photomultipliers

most common detector

80
New cards

Diode-array instruments

  • The optical configuration is reversed from that in a conventional spectrophotometer, and the light beam passes through the sample before being dispersed by the polychromator

  • Gives the benefit of fast, full spectral data with no moving parts that can wear out (unlike monochromator)

    • other advantage: can obtain absorbance spectrum at once


81
New cards

HPLC detectors

  • High-stability, low signal-to-noise ratio output at high transmittance levels through a small-aperture flow cell

  • Used during dissolution

    • In dissolution, drug release is analyzed per time period


82
New cards

FALSE (Xenon flash lamps)

[T/F] Fiber-optic based modular systems (disadvantage): Light levels transmitted directly down fibers from high-intensity sources, such as deuterium arc, may cause photodegradation

83
New cards
  • instrumental factors

  • sample-based factors

  • sampling factors


3 analytical considerations

84
New cards

instrumental factors

[analytical considerations]

  • spectral bandwidth

  • stray light

  • optimum working photometric range


85
New cards

sample-based factors

[analytical considerations]

  • fluorescence & light-scattering


86
New cards

sampling factors

[analytical considerations]

  • cells

  • care of cells

  • alignment and filling of cells

  • cell corrections


87
New cards

Spectral bandwidth

The width of the band of light at one-half the peak maximum (or full width at half maximum [FWHM]) that will analyze the sample

88
New cards

2 nm

adequate spectral bandwidth (greater than this can cause errors)

89
New cards

Stray light

Radiant energy at wavelengths other than those indicated by the monochromator setting and all radiant energy that reaches the detector without having passed through the sample or reference solutions

90
New cards

Stray light

Causes of ___

  • Any scattered radiation from imperfections in the dispersing medium 

  • Light leaks in the system 

  • Incorrect wavelength calibration 

  • Incorrect optical alignment 

  • Reduced source output

  • Reduced detector response


91
New cards

Optimum working photometric range

The center plateau is the photometric range in this spectrum of molar absorptivities  at different concentrations

92
New cards

Fluorescence & Light-scattering

The measured signal usually will contain a contribution from fluorescence

93
New cards

Tyndall effect

Suspended particles scatter light by the ___, causing a decrease in the measured intensity that increases as the wavelength decreases

94
New cards

TRUE (not emitted light)

[T/F] Absorbed light is measured in UV-vis

95
New cards

FALSE (not dissolved suspended particles)

[T/F] Light scattering is due to dissolved particles

96
New cards

TRUE

[T/F] Improved sensitivity generally can be obtained by increasing the cell path length

97
New cards

FALSE (Beer’s Law)

[T/F] Lambert’s Law states that the concentration of a chemical solution is directly proportional to its absorption of light

98
New cards

TRUE

[T/F] Lambert’s Law states that each layer of equal thickness of the medium absorbs an equal fraction of the energy traversing it

99
New cards

Beer-Lambert’s Law

states that the quantity of light absorbed by a substance dissolved in a fully transmitting solvent is directly proportional to the concentration of the substance and the path length of the light through the solution

100
New cards

TRUE

[T/F] %absorbed light =/= absorbance