1/100
Spectroscopy
the study of the absorption and emission of light and other radiation by matter
Spectrometry
the measurement of the interactions between light and matter, and the reactions and measurements of radiation intensity and wavelength
Spectrophotometry
the quantitative measurement of the reflection or transmission properties of a material as a function of wavelength
TRUE
[T/F] Particles are moved from their normal room temperature state, or ground state, to one or more higher-energy excited states
FALSE (electromagnetic energy)
[T/F] Mechanical energy is transferred to the atoms, ions or molecules of the sample when radiation passes through a layer of solid, liquid or gas
Electromagnetic radiation
produced when excited particles (atoms, ions or molecules) relax to lower energy levels by giving up their excess energy as photons
Photons
electromagnetic radiation is produced when excited particles (atoms, ions or molecules) relax to lower energy levels by giving up their excess energy as ___
Emission
reciprocal of absorption
TRUE
[T/F] In emission, particle starts from the excited state to the ground state by releasing its energy
4 Causes of Emission
Bombardment w/ electrons or elementary particles, which leads to emission of X-rays
Exposure to an electric current or intense heat source producing UV, visible or IR radiation
Irradiation with a beam of electromagnetic radiation
An exothermic chemical rxn that produces chemiluminescence
gamma rays
electrons:x-ray : nucleus:___
electrons
___:x-ray : nucleus:gamma rays
TRUE
[T/F] Electrons from the outer shell have higher energy states than those in the inner shell
FALSE (repulsion; the electron will move away until it is removed/released from the atom)
[T/F] Interaction of electron and another electron will result to attraction
FALSE (inner shell)
[T/F] Rule in placing electrons: always fill in the outer shells first
TRUE
[T/F] Exposure of the particle with electromagnetic radiation will also result to emission of radiation
Scattering of Radiation
electromagnetic radiation is transmitted at all angles from the original path
FALSE (smaller)
[T/F] Scattering of radiation is usually observed when atomic or molecular particles are slightly bigger relative to the wavelength of the radiation
Diffraction of Radiation
a parallel beam of radiation is bent as it passes by a sharp barrier or through a narrow opening
Electromagnetic Radiation
Type of energy that is commonly known as light
Electric
radiation oscillating vertically
Magnetic
radiation oscillating horizontally
Sinusoidal Wave Model
Particle Model
2 EM models
Sinusoidal Wave Model
[EM models] Wavelength, frequency, velocity, and amplitude
Particle Model
[EM models] Viewed as a stream of discrete particles, or wave packets, of energy called photons
Sinusoidal Wave Model
more accepted EM model
amplitude (A)
[Parts of a Wave] Distance of the vector to the highest point of the wave
period (p)
[Parts of a Wave] The time in seconds where 2 maxima or 2 minima propagate
expressed in sec
frequency (v)
[Parts of a Wave] Number of oscillation (one wave propagation) per second
expressed in Hz, /sec, CPS
wavelength (λ)
[Parts of a Wave] Distance between 2 maxima (Peak or Crest) or 2 minima (Trough)
expressed in nm, mm, cm, Å
wavenumber
[Parts of a Wave] Reciprocal of wavelength
expressed in /nm, /mm, /cm, /Å
3.00 × 108 m/s
speed of light (c)
6.626 × 10-34 J•s
Planck’s constant
10 Å
[Conversion] 1 nm = ___ Å
107 ergs
[Conversion] 1 J = ___ ergs
1.6 × 10-19 J
[Conversion] 1 eV = ___ J
7.9512 x 10-19 J
[Calculation] A light of wavelength 250 nm strikes a metal surface. Calculate the energy in J of the incident photon
828.25 nm
[Calculation] Calculate the wavelength (in nm) of the light that strikes a solution given that the energy of the incident photon is 1.5 eV
Quantum Theory
theory that states that the energy of a photon absorbed or emitted during a transition from one molecular energy level to another is given by the equation: E = hv
Ultraviolet-visible (UV-Vis) spectroscopy
an electronic transition spectroscopic technique in which the interaction between incident radiation and electrons results in the promotion of one or more of the outer or the bonding electrons from a ground state into a higher-energy state
Absorbance
difference between the incident and transmitted light
200-380 nm
UV light range (nm)
380-700 nm
visible light range (nm)
200-700 nm
UV-vis spectrum (nm)
TRUE (also, longer wavelength = lower energy)
[T/F] The more loosely held the electrons are within the bonds of the molecule, the longer the wavelength of the radiation absorbed.
Chromophores
extended system of double bonds that causes absorption of light at UV-visible region
Chromophores
The functional group needed to analyze using UV-Vis; only they can absorb light in this region
Alizarin (red)
[natural organic pigments] from madder root
Kermesic/Carminic acid (red-pink)
[natural organic pigments] from the insect Coccus cacti
Indigo
[natural organic pigments] from Isatis tinctoria (woad)
Punicin / Tyrian purple
[natural organic pigments] from mollusks of the genus Murex
β-carotene (orange)
[natural organic pigments] from carrots
crocetin (yellow-brown)
[natural organic pigments] from saffron
continuum source
mono-/polychromator
sampling area
detector
4 parts of instrumentation
Collimator
Gathers and directs the light into the Monochromator
Monochromator
Disperses the light into its component wavelengths
continuous
pulsed
2 types of light source
visible (continuous)
[uv/vis light source] tungsten halogen
uv (continuous)
[uv/vis light source] deuterium arc
uv & vis (continuous)
[uv/vis light source] xenon arc
uv & vis (pulsed)
[uv/vis light source] xenon flash lamp
Monochromator
used to disperse (separate) the light into its constituent wavelengths, which are further selected by the slit (wavelength selector)
TRUE (opposite for polychromators)
[T/F] Monochromators allow the dispersion of light before it passes through the sample
Absorbance spectrum
spectrum of absorbances using a spectrum of radiation; absorbances at different wavelengths
Amax
peak of absorbance spectrum; wavelength of maximum (highest) absorbance
TRUE
[T/F] Monochromators are rotated so that a range of wavelengths is passed through the sample as the instrument scans across the spectrum
Polychromator
have multiple exit slits, each of which allows a different wavelength to pass through it
based on material (quartz, plastic, optical glass)
based on size (1cm, 2cm, 4cm)
cuvette types
uv & vis
[cuvette use] quartz
vis
[cuvette use] plastic
vis
[cuvette use] optical glass
fiber-optic-based immersion probes
flow cells
automated sample changers
micro-well plate configurations
4 uv-vis arrangements
fiber-optic-based immersion probes
[uv-vis arrangements]
The sample is not inside the instrument.
Probe the sample at its original container.
flow cells
[uv-vis arrangements]
or “flow through cell”
Has an inlet and outlet where the sample flows
The drug can be analyzed at different points or time intervals since the sample is flowing.
automated sample changers
[uv-vis arrangements]
Can analyze multiple samples by automating rotations.
micro-well plate configurations
[uv-vis arrangements]
for micro-volume and high-throughput applications
high-throughput = analyze a very large number of samples or data points rapidly
Detector
converts analytical signal → electrical signal
Photoelectric detectors
generate an electric current (electrical signal) that is directly proportional to the intensity of the radiant energy (analytical signal) incident upon them
Photomultipliers
most common detector
Diode-array instruments
The optical configuration is reversed from that in a conventional spectrophotometer, and the light beam passes through the sample before being dispersed by the polychromator
Gives the benefit of fast, full spectral data with no moving parts that can wear out (unlike monochromator)
other advantage: can obtain absorbance spectrum at once
HPLC detectors
High-stability, low signal-to-noise ratio output at high transmittance levels through a small-aperture flow cell
Used during dissolution
In dissolution, drug release is analyzed per time period
FALSE (Xenon flash lamps)
[T/F] Fiber-optic based modular systems (disadvantage): Light levels transmitted directly down fibers from high-intensity sources, such as deuterium arc, may cause photodegradation
instrumental factors
sample-based factors
sampling factors
3 analytical considerations
instrumental factors
[analytical considerations]
spectral bandwidth
stray light
optimum working photometric range
sample-based factors
[analytical considerations]
fluorescence & light-scattering
sampling factors
[analytical considerations]
cells
care of cells
alignment and filling of cells
cell corrections
Spectral bandwidth
The width of the band of light at one-half the peak maximum (or full width at half maximum [FWHM]) that will analyze the sample
2 nm
adequate spectral bandwidth (greater than this can cause errors)
Stray light
Radiant energy at wavelengths other than those indicated by the monochromator setting and all radiant energy that reaches the detector without having passed through the sample or reference solutions
Stray light
Causes of ___
Any scattered radiation from imperfections in the dispersing medium
Light leaks in the system
Incorrect wavelength calibration
Incorrect optical alignment
Reduced source output
Reduced detector response
Optimum working photometric range
The center plateau is the photometric range in this spectrum of molar absorptivities at different concentrations
Fluorescence & Light-scattering
The measured signal usually will contain a contribution from fluorescence
Tyndall effect
Suspended particles scatter light by the ___, causing a decrease in the measured intensity that increases as the wavelength decreases
TRUE (not emitted light)
[T/F] Absorbed light is measured in UV-vis
FALSE (not dissolved suspended particles)
[T/F] Light scattering is due to dissolved particles
TRUE
[T/F] Improved sensitivity generally can be obtained by increasing the cell path length
FALSE (Beer’s Law)
[T/F] Lambert’s Law states that the concentration of a chemical solution is directly proportional to its absorption of light
TRUE
[T/F] Lambert’s Law states that each layer of equal thickness of the medium absorbs an equal fraction of the energy traversing it
Beer-Lambert’s Law
states that the quantity of light absorbed by a substance dissolved in a fully transmitting solvent is directly proportional to the concentration of the substance and the path length of the light through the solution
TRUE
[T/F] %absorbed light =/= absorbance