Section 2 - Gas Chromatography Part 1

0.0(0)
Studied by 0 people
call kaiCall Kai
learnLearn
examPractice Test
spaced repetitionSpaced Repetition
heart puzzleMatch
flashcardsFlashcards
GameKnowt Play
Card Sorting

1/27

encourage image

There's no tags or description

Looks like no tags are added yet.

28 Terms

1
New cards

gaseous, carrier gas

In GC, the analyte is transported through the column by ___ mobile phase, called the ____ ____.

2
New cards

nonvolatile liquid

In gas-liquid partition chromatography, the stationary phase is a ____ ___ that is bonded to the inside of the column.

3
New cards

solid

In gas-solid chromatography, the stationary phase is a ___ and the analyte molecules adsorb directly onto the surface.

4
New cards
<p>.</p>

.

Draw the basic setup of a gas chromatography machine.

5
New cards

capillary column

In most GCs, the column is a narrow open tubular column called a ___ ___.

6
New cards

open tubular

____ ____ columns provide a higher resolution, shorter analysis time, and greater sensitivity than packed columns.

7
New cards

wall-coated open tubular column (WCOT)

What is this open tubular column type?

<p>What is this open tubular column type?</p>
8
New cards

support-coated open tubular column (SCOT)

What is this open tubular column type?

<p>What is this open tubular column type?</p>
9
New cards

porous-layer open tubular column (PLOT)

What is this open tubular column type?

<p>What is this open tubular column type?</p>
10
New cards

chromatogram

The ____ is a graph showing the detector response as a function of elution time.

11
New cards

retention time (tr)

The ____ for each component is the time between injection and detection of that component.

12
New cards

minimum retention time (tm)

The ___ is the minimum time required for solvent to travel the length of the column.

13
New cards

adjusted retention time (tr’)

The ___ is the additional time required to elute a solute beyond the time required by the solvent. The amount of time that the solute is not moving down the column.

14
New cards

relative retention (separation factor)

The ____ is the ratio of components 1 and 2 in their adjusted retention times.

15
New cards

doesn’t

Relative retention generally ____ change when the flow rate is changed.

16
New cards

retention factor (k)

The ___ of a component is the adjusted retention time for that component expressed in multiples of the time required for the mobile phase to travel the column.

17
New cards

2-10

The desired retention factor is between ___.

18
New cards

increases

When you decrease the column diameter, the retention time ____.

19
New cards

increases

When you increase the column length, the chromatogram resolution _____.

20
New cards

decreases

decreasing the stationary phase thickness ____ the retention time and sample capacity.

21
New cards

bleeding

At higher operating temperatures, the stationary phase can decompose causing ____ which increases background signal.

22
New cards

oxidation

____ of the stationary phase must be avoided.

23
New cards

helium

Most common carrier gas.

24
New cards

helium, nitrogen gas, and hydrogen gas

Examples of carrier gases.

25
New cards

lighter gas

Helium and hydrogen has provide better resolution than nitrogen gas because the solutes diffuse more rapidly through…

26
New cards

temperature

Nonpolar stationary phases are affected by ____ where polar stationary phases are not.

27
New cards

boiling point

For nonpolar stationary phases, the compounds are eluted largely in the order of increasing _____.

28
New cards

hydrogen bonding and dipole dipole interaction

In polar stationary phases, the compound retention is strongly determined by…