Structured Cabling System

A network infrastructure consisting of cable, jacks, faceplates, patch or adapter panels, cable trays, conduit systems, boxes, enclosures, and all associated support and suspension systems.

2
New cards

Category 3 (Cat 3) Cable

A UTP cable with transmission rates up to 16 MHz16\,\text{MHz} historically used for Ethernet networks with speeds of 10 Mbps10\,\text{Mbps}, not recommended for new installations except for analog data or voice-only applications.

3
New cards

Category 5e (Cat 5e) Cable

An enhanced version of Cat 5 cable with transmission rates up to and exceeding 100 MHz100\,\text{MHz}, used for Ethernet networks with speeds of 100 Mbps100\,\text{Mbps} and sometimes 1 Gbps1\,\text{Gbps}.

4
New cards

Category 6 (Cat 6) Cable

A twisted-pair cable with transmission rates up to 250 MHz250\,\text{MHz}, typically considered to support a 1 Gbps1\,\text{Gbps} data rate.

5
New cards

Category 6A (Cat 6A) Cable

An augmented version of Cat 6 cable with transmission rates up to 500 MHz500\,\text{MHz} (10 Gbps10\,\text{Gbps} data rate) that uses the RJ-45 connector but is thicker and bulkier.

6
New cards

Category 8 (Cat 8) Cable

A cable offering transmission rates up to 2 GHz2\,\text{GHz} (2,000 MHz2{,}000\,\text{MHz}) that supports data rates of 25 Gbps25\,\text{Gbps} or 40 Gbps40\,\text{Gbps} and is limited to a maximum length of 98 ft (30 m)98\,\text{ft}\,(30\,\text{m}).

7
New cards

Campus Backbone Subsystem

The subsystem that provides outside plant connectivity between buildings in a multi-building campus environment, including the entrances for each building.

8
New cards

Equipment Room Subsystem

The centralized area where all subsystems for an individual building or the entire campus connect, such as an equipment room (ER), telecommunications room (TR), or main cross-connect (MC).

9
New cards

Riser Subsystem

The blocks, cables, pathways, and hardware that provide connectivity between equipment rooms (ERs), telecommunications rooms (TRs), and main cross-connects (MCs).

10
New cards

Horizontal Cabling Subsystem

The patch panels, cables, support structures, and hardware that deliver voice and data connectivity to the end-user outlet location.

11
New cards

Work Area Subsystem

The telecommunications outlets at the end-user location and the associated patch cables providing final connectivity.

12
New cards

Smart LB Conduit Body

A specialized conduit body designed with a gentler bend radius than traditional sharp 90∘90^{\circ} Type L conduit bodies to prevent cable damage and satisfy ANSI/TIA-568 pulling requirements.

13
New cards

Service Loop

An extra length of neatly coiled, labeled, and secured overhead cable (up to 15 ft [4.6 m]15\,\text{ft}\,[4.6\,\text{m}] at the ER/TR/MC and 18 in [450 mm]18\,\text{in}\,[450\,\text{mm}] at the field end) preserved to facilitate future re-termination.

14
New cards

Diver

A cable dressing defect in which an individual cable crosses over and disappears into the center of a bundled cable run.

15
New cards

Split Kellum's Grip

A mechanical support device used to secure continuous vertical riser cables at intervals of no more than 30 ft (9 m)30\,\text{ft}\,(9\,\text{m}).

16
New cards

Distributed Antenna System (DAS)

A series of antennas located within a building that disseminate a specific signal throughout the structure to enhance coverage and support first-responder communications under NFPA 72 and NFPA 1221.

17
New cards

Registered Jack (RJ)

The telecommunications term abbreviated as 'RJ' in standardized hardware interfaces such as the RJ-45 connector.

18
New cards

Straight-Through Patch Cord

A patch cable wired to the exact same scheme (either ANSI/TIA-568A or ANSI/TIA-568B) on both ends to pass signals unchanged from jack to jack.

19
New cards

Crossover Patch Cord

A patch cable wired according to the ANSI/TIA-568A scheme on one end and the ANSI/TIA-568B scheme on the opposite end, allowing signal transition between different pin configurations.

20
New cards

Simplex Cable

A fiber optic cable designed to transmit optical data in only one direction.

21
New cards

Duplex Cable

A fiber optic cable designed to transmit optical data in both directions.

22
New cards

Single-Mode (SM) Fiber

Optical fiber with a core size of 8.3 μm8.3\,\mu\text{m} designed primarily for long-distance data transmission.

23
New cards

Multimode (MM) Fiber

Optical fiber available in 50 μm50\,\mu\text{m} or 62.5 μm62.5\,\mu\text{m} core sizes, commonly used to achieve higher transmission speeds over shorter distances.

24
New cards

Attenuation

The reduction or loss of signal strength that occurs during transmission along copper or fiber optic pathways.

25
New cards

Splice Closure

A sealed mechanical and environmental enclosure used to protect joined fiber strands when switching cable types or spanning distances longer than a single cable run.

26
New cards

Adapter Panel

A modular panel within a fiber optic enclosure featuring a fixed side and an equipment side to allow convenient interconnection and rearrangement of circuits using patch cords.

27
New cards

Fusion Splicer

A device that permanently joins optical fibers using electric heat to fuse the glass ends, offering lower return loss than mechanical splices.