1/63
Looks like no tags are added yet.
Conduction Pathway
SA Node → Atria → AV Node → Bundle of His → Right & Left Bundle Branches → Purkinje Fibers → Ventricles
SA Node
Located in the right atrium
SA Node
The heart's natural pacemaker (fires first / fastest)
SA Node
Normally initiates the impulse that makes the atria contract
SA Node
Normal intrinsic rate is 60–100 bpm
SA Node
60–100 bpm IS normal sinus rhythm rate
Atrial Depolarization
Impulse spreads through both atria → atrial contraction, pushing blood into the ventricles
Atrial Depolarization
Recorded on ECG as the P wave
AV Node
Impulse arrives and conduction is deliberately SLOWED here
AV Node
Purpose of the delay is to give the ventricles time to fill with blood before they contract
AV Node
This delay is the PR interval on the ECG
Bundle of His
After the AV delay, impulse travels through the bundle of His toward the ventricles
R & L Bundle Branches
Carry the impulse down the septum toward the ventricular apex (right and left sides)
Purkinje Fibers
Distribute the impulse throughout the ventricular myocardium → ventricular contraction
Purkinje Fibers
Recorded on ECG as the QRS complex
Conduction Pathway Mnemonic
"Some Athletes Always Body-Build Really Powerfully, Vigorously" → SA node → Atria → AV node → Bundle of His → Right/Left bundle branches → Purkinje fibers → Ventricles
Structure That Delays the Impulse
The AV node — this is the #1 fact tested about it
Heart's Natural Pacemaker
The SA node, never the AV node
ECG Paper Horizontal Axis
TIME
ECG Paper Vertical Axis
Voltage/amplitude (how strong the electrical signal is)
1 Small Square (ECG)
0.04 second
1 Large Square (5 small squares) (ECG)
0.20 second
30 Large Squares (ECG)
6 seconds
5 mm Height (ECG)
0.5 mV
Small Square (ECG Paper Math)
Time AND the building block for everything else: 5 small squares
6-Second Strip (30 large squares)
The classic bedside trick for quickly estimating heart rate: count QRS complexes in the strip × 10
P Wave
Represents atrial depolarization
PR Interval
Represents time for impulse to travel from atria, through the AV node/conduction system, to the ventricles
PR Interval
Measured from beginning of P wave to beginning of QRS complex
PR Interval
Normal value is 0.12–0.20 second
QRS Complex
Represents ventricular depolarization
QRS Complex
Measured from beginning of Q wave to end of S wave
QRS Complex
Normal value is ≤ 0.12 second
T Wave
Represents ventricular repolarization
P Wave (Rapid Recall)
Atrial depolarization
QRS Complex (Rapid Recall)
Ventricular depolarization
T Wave (Rapid Recall)
Ventricular repolarization
Atrial Repolarization
There is no separate wave for atrial repolarization — it's small and hidden inside the QRS complex (classic distractor option)
PR Interval (Rapid Recall)
"AV conduction/delay time"
Long PR Interval
A conduction delay at the AV node — this is literally what 1st-degree AV block is
Exam Trap (P Wave/QRS)
"P wave
First-Degree AV Block
Impulse conducts but is consistently delayed (prolonged PR interval)
First-Degree AV Block
Every P wave still has a QRS
Second-Degree AV Block, Type I (Wenckebach/Mobitz I)
PR interval progressively lengthens until a QRS is "dropped"
Second-Degree AV Block, Type II (Mobitz II)
PR interval stays constant, but QRS complexes are randomly/intermittently dropped
Second-Degree AV Block, Type II (Mobitz II)
Considered more dangerous than Type I
Third-Degree AV Block (Complete Heart Block)
Atria and ventricles beat completely independently of each other
Third-Degree AV Block (Complete Heart Block)
No relationship between P waves and QRS complexes
Right Bundle Branch Block (RBBB)
Delayed conduction down the right bundle branch
Left Bundle Branch Block (LBBB)
Delayed conduction down the left bundle branch
Limb Leads
Wrists/ankles are standard placement
Limb Leads
Alternative placement is upper arms/thighs if wrists/ankles are not accessible
V4 Chest Lead Placement
5th intercostal space, midclavicular line
Skin Preparation (ECG)
Clean the skin if oily, sweaty, or dirty
Skin Preparation (ECG)
Allow the skin to dry completely before applying electrodes
Skin Preparation (ECG)
Remove excessive hair if necessary, according to facility policy
Nursing Action If ECG Tracing Shows Excessive Artifact
Check the patient's position
Nursing Action If ECG Tracing Shows Excessive Artifact
Ask the patient to remain still
Nursing Action If ECG Tracing Shows Excessive Artifact
Check/reinforce electrode adhesion to the skin
"Slows the Impulse to Let Ventricles Fill" (Exam Cue)
AV node
"Prolonged/Lengthening PR Interval" (Exam Cue)
A clue pointing to first-degree block or Mobitz I (Wenckebach)
"Dropped QRS, PR Interval Constant" (Exam Cue)
Mobitz II (2nd-degree, Type II) — the more dangerous second-degree block
"No Relationship Between P Waves and QRS" (Exam Cue)
Third-degree (complete) heart block
Artifact on the Strip (Exam Cue)
Think patient movement/position first, then electrode contact — not the machine itself