Conduction Pathway

SA Node → Atria → AV Node → Bundle of His → Right & Left Bundle Branches → Purkinje Fibers → Ventricles

2
New cards

SA Node

Located in the right atrium

3
New cards

SA Node

The heart's natural pacemaker (fires first / fastest)

4
New cards

SA Node

Normally initiates the impulse that makes the atria contract

5
New cards

SA Node

Normal intrinsic rate is 60–100 bpm

6
New cards

SA Node

60–100 bpm IS normal sinus rhythm rate

7
New cards

Atrial Depolarization

Impulse spreads through both atria → atrial contraction, pushing blood into the ventricles

8
New cards

Atrial Depolarization

Recorded on ECG as the P wave

9
New cards

AV Node

Impulse arrives and conduction is deliberately SLOWED here

10
New cards

AV Node

Purpose of the delay is to give the ventricles time to fill with blood before they contract

11
New cards

AV Node

This delay is the PR interval on the ECG

12
New cards

Bundle of His

After the AV delay, impulse travels through the bundle of His toward the ventricles

13
New cards

R & L Bundle Branches

Carry the impulse down the septum toward the ventricular apex (right and left sides)

14
New cards

Purkinje Fibers

Distribute the impulse throughout the ventricular myocardium → ventricular contraction

15
New cards

Purkinje Fibers

Recorded on ECG as the QRS complex

16
New cards

Conduction Pathway Mnemonic

"Some Athletes Always Body-Build Really Powerfully, Vigorously" → SA node → Atria → AV node → Bundle of His → Right/Left bundle branches → Purkinje fibers → Ventricles

17
New cards

Structure That Delays the Impulse

The AV node — this is the #1 fact tested about it

18
New cards

Heart's Natural Pacemaker

The SA node, never the AV node

19
New cards

ECG Paper Horizontal Axis

TIME

20
New cards

ECG Paper Vertical Axis

Voltage/amplitude (how strong the electrical signal is)

21
New cards

1 Small Square (ECG)

0.04 second

22
New cards

1 Large Square (5 small squares) (ECG)

0.20 second

23
New cards

30 Large Squares (ECG)

6 seconds

24
New cards

5 mm Height (ECG)

0.5 mV

25
New cards

Small Square (ECG Paper Math)

Time AND the building block for everything else: 5 small squares

26
New cards

6-Second Strip (30 large squares)

The classic bedside trick for quickly estimating heart rate: count QRS complexes in the strip × 10

27
New cards

P Wave

Represents atrial depolarization

28
New cards

PR Interval

Represents time for impulse to travel from atria, through the AV node/conduction system, to the ventricles

29
New cards

PR Interval

Measured from beginning of P wave to beginning of QRS complex

30
New cards

PR Interval

Normal value is 0.12–0.20 second

31
New cards

QRS Complex

Represents ventricular depolarization

32
New cards

QRS Complex

Measured from beginning of Q wave to end of S wave

33
New cards

QRS Complex

Normal value is ≤ 0.12 second

34
New cards

T Wave

Represents ventricular repolarization

35
New cards

P Wave (Rapid Recall)

Atrial depolarization

36
New cards

QRS Complex (Rapid Recall)

Ventricular depolarization

37
New cards

T Wave (Rapid Recall)

Ventricular repolarization

38
New cards

Atrial Repolarization

There is no separate wave for atrial repolarization — it's small and hidden inside the QRS complex (classic distractor option)

39
New cards

PR Interval (Rapid Recall)

"AV conduction/delay time"

40
New cards

Long PR Interval

A conduction delay at the AV node — this is literally what 1st-degree AV block is

41
New cards

Exam Trap (P Wave/QRS)

"P wave

42
New cards

First-Degree AV Block

Impulse conducts but is consistently delayed (prolonged PR interval)

43
New cards

First-Degree AV Block

Every P wave still has a QRS

44
New cards

Second-Degree AV Block, Type I (Wenckebach/Mobitz I)

PR interval progressively lengthens until a QRS is "dropped"

45
New cards

Second-Degree AV Block, Type II (Mobitz II)

PR interval stays constant, but QRS complexes are randomly/intermittently dropped

46
New cards

Second-Degree AV Block, Type II (Mobitz II)

Considered more dangerous than Type I

47
New cards

Third-Degree AV Block (Complete Heart Block)

Atria and ventricles beat completely independently of each other

48
New cards

Third-Degree AV Block (Complete Heart Block)

No relationship between P waves and QRS complexes

49
New cards

Right Bundle Branch Block (RBBB)

Delayed conduction down the right bundle branch

50
New cards

Left Bundle Branch Block (LBBB)

Delayed conduction down the left bundle branch

51
New cards

Limb Leads

Wrists/ankles are standard placement

52
New cards

Limb Leads

Alternative placement is upper arms/thighs if wrists/ankles are not accessible

53
New cards

V4 Chest Lead Placement

5th intercostal space, midclavicular line

54
New cards

Skin Preparation (ECG)

Clean the skin if oily, sweaty, or dirty

55
New cards

Skin Preparation (ECG)

Allow the skin to dry completely before applying electrodes

56
New cards

Skin Preparation (ECG)

Remove excessive hair if necessary, according to facility policy

57
New cards

Nursing Action If ECG Tracing Shows Excessive Artifact

Check the patient's position

58
New cards

Nursing Action If ECG Tracing Shows Excessive Artifact

Ask the patient to remain still

59
New cards

Nursing Action If ECG Tracing Shows Excessive Artifact

Check/reinforce electrode adhesion to the skin

60
New cards

"Slows the Impulse to Let Ventricles Fill" (Exam Cue)

AV node

61
New cards

"Prolonged/Lengthening PR Interval" (Exam Cue)

A clue pointing to first-degree block or Mobitz I (Wenckebach)

62
New cards

"Dropped QRS, PR Interval Constant" (Exam Cue)

Mobitz II (2nd-degree, Type II) — the more dangerous second-degree block

63
New cards

"No Relationship Between P Waves and QRS" (Exam Cue)

Third-degree (complete) heart block

64
New cards

Artifact on the Strip (Exam Cue)