1/44
Looks like no tags are added yet.
Types of Digital Radiography
CR
SPR
Indirect DR
Indirect DR
Direct DR
CR elements
Capture: BaF PSP
Coupling: Lens/fiber optics
Collection: Photodetector
SPR
Capture:Nal/Csl
Coupling: None
Collection: Photodetector
Indirect DR (1)
Capture: Csl
Coupling: fiber optics
Collection: CCD/CMOS
Indirect DR (2)
Capture: Csl, GdOS
Coupling: contact layer
Collection: TFT
Direct DR
Capture: a-Se
Coupling: None
Collection: TFT
Whats capture element
Absorbs incoming x-rays and converts them into light or electrical charge.
Whats a coupling element
transfers the signal from the capture element to the collection element.
Whats the collection element
Collects the signal and helps convert it into a digital image.
CR: BaF (PSP) function?
Captures xrays in crystals (BaF) then converts them to light useing laser on F traps (Eu activator)
CR: Lens/fiber optics function + types
Transpher light to photo detector
Beam shaping: straightns beam
Light collecting: removes low energy
CR: Photodetector
PMT: converts light to digital signal
SPR stands for
Scanned projection Radiography
SPR function
Scans like a fan beam
Patient moves threw
Slow
Large
Expensive
Nal/Csl function
Convert light into electorns
SPR: photodetector
Photodiodes: convert light into electronic signal
Indirect DR (1)
Plate built into machine: just insert grid
Indirect DR: CsI
Scintillator: converts x-ray to light
Crystals abosrb xray and convert to light
Light travels threw optic fibers to collection element
Indirect DR (1) CCD made of
semiconductor chip containing thousands or millions of tiny light-sensitive areas called pixels/dels.
Indirect DR (1) CCD after light hits
Electron hole pairs are produced
Held by electrostatic forces untill read
Inside hole being filled: overflow = blooming effect
Indirect DR (1) CCD chip layers
Polysilicon layer
Silicon dioxide layer
Silicon substrate
Indirect DR (1) CCD steps
Collect light
Voltage gate (on/off): move electrons along line (lose energy) (dels/pixels)
End at readout row: get transformed to electronic signal
Indirect DR (1) CCD advantage
Respond to low amounts of light (less dose)
Dynamic range
Size: small
100% fill factor
Easy to replace
Indirect DR (1) CCD disadvantage
Demagnification: shrinks then enlarge
Reduce DQE (detective quotum efficiency
Dosent count every data point
Indirect DR (1) CMOS
Same as CCD but
Has readout circuitry at each pixel.
Pixels can be read individually. Dosent have common readout area
Types of noise
Statstical (quantum mottle): low amount of photons from scintillator
Dark: without radiation (due to cold temp)
Amplification: bad pixels, due to system
CMOS vs CCD
CMOS better:
Price
Uses little power
Faster
Compact
CCD better:
More light sensitive
Less noise susceptibility
More fill factor
Better spacial resolution
Indirect DR (2)
Uses plate
Indirect DR (2): CsI, GdOS
scintillators
CsI: needle structure
GdOS: powder structure (turbid)
Indirect DR (2): pathway
CsI/GdOS: Converts x-rays into light.
Contact layer: transfers light
Active Matrix Flat-Panel Imagers: Contains the pixel circuitry, including photodiodes and TFT switches.
Photodiodes: Absorb the light and convert it into electrical charges.
TFT switches: Control the readout of electrical charges.
Readout electronics and A/D converter:
TFT
Thin Film transistor
Sends signal to computer
-80% fill factor
Indirect DR (2): Each pixel has
Light sensitive area
Capacitor: holds info read line by line
TFT
Measure detector preformance
Spatial resolution + (DQE)
Contrast objects in contrast detail phantom
Signal to noise ratio (modern)
Small pixel size =
Better resoloution
Lower fill factor
More dose
Direct DR: A-se
Comvert xray to electrons (no scintillating)
Direct DR: pathway
A-se: form charged pairs (electron pairs) when hit with xray
Collected by storage capacitor untill read by TFT
Direct vs Indirect
Direct
Better resolution (no light spread)
Indirect
Less dose
Both
Same fill factor
CR worst to best resolution
Screen film (400 speed)
CR
a-Si
CCD
a-Se
Screen film (100 speed)
BaF
Barium Fluoroide
Nal/CsI
NaI = Sodium Iodide
CsI = Cesium Iodide
GdOs
Gadolinium Oxysulfide.
a-Se
Amorphous Selenium
A-si
Amorphous Silicon
DQE
Detective Quantum Efficiency.
How effective xray convert to signal
CCD
Charge-Coupled Device.