1/109
Comprehensive vocabulary flashcards detailing the dimensional standards, gradients, facility clearances, penalties, and designated seating ratios under Batas Pambansa Blg. 344 (BP 344) and its 2024 amendments.
Batas Pambansa Blg. 344 (BP 344)
Also known as the Accessibility Law, enacted on February 25, 1983, to promote the mobility and accessibility of persons with disabilities.
R.A. 7277 Section 46 Penalties (First Violation)
A fine of not less than P50,000.00 but not exceeding P100,000.00, or imprisonment of not less than 6 months but not more than 2 years, or both at the discretion of the court.
R.A. 7277 Section 46 Penalties (Subsequent Violation)
A fine of not less than P100,000.00 but not exceeding P200,000.00, or imprisonment of not less than 2 years but not more than 6 years, or both at the discretion of the court.
Wheelchair Dimensions (Amended BP 344)
Standard dimensions specified as 1.10m in length by 0.80m in width.
Wheelchair Turning Space
A circular clear area with a required diameter of 1.80m.
Knee Clearance Under Tables
A minimum vertical clearance of 0.70m beneath tables for wheelchair accessibility.
Seating Space (Assembly Areas)
Designated space measuring 0.90m in width by 1.10m in length.
Wheelchair Reach (Vertical)
A vertical reach range of 0.70m to 1.20m, reduced to a maximum of 1.10m when reach is obstructed.
Wheelchair Reach (Horizontal)
A horizontal reaching distance range of 0.50m to 0.90m.
Ramp Gradient (Main)
A maximum slope of 1:20, with 1:15 permitted for special cases or limited ramp lengths.
Curb Ramp Gradient
A maximum allowable slope of 1:15.
Ramp Width (Amended BP 344)
A clear unobstructed width of 1.20m (unchanged under the 2024 amendment).
Handrail Height (Ramps)
Dual continuous handrails required at both 0.70m and 0.90m heights.
Handrail Extension
A required extension of 300mm beyond the top and bottom of ramps or stairs.
Railings/Handrail Diameter
A standard grip diameter ranging between 30mm and 40mm.
Curbs / Edge Protection Height
A minimum edge protection barrier height of 100mm.
Stairs Maximum Riser Height
A maximum stair step height of 150mm.
Stairs Minimum Tread Width
A minimum stair step tread depth of 300mm.
Tactile Warning Strips (Stairs)
Tactile surfacing with a depth of 600mm, installed 300mm before stairs or hazardous areas.
Stair Width and Landing Depth
Both clear stair width and stair landing depth require a minimum measurement of 1.50m.
Door Minimum Clear Width
A minimum doorway opening width of 900mm (0.90m).
Door Level Space (Turnaround)
A level maneuvering space of 1.80m×1.80m before and extending beyond the door.
Door Hardware Height
Knobs and pulls centered at a height of 900mm (0.90m).
Door Kick Plate Height
Protective plate located at the bottom of doors with a height of 300mm to 400mm.
Door Vision Panel Height
A viewing window positioned from a maximum of 0.90m at its bottom edge to a minimum of 1.50m at its top edge.
Corridors and Walkways Minimum Width
A baseline clear width of 1.50m, increasing to 1.80m to allow two wheelchairs to pass simultaneously.
Corridors and Walkways Headroom
A minimum unobstructed vertical ceiling clearance of 2.20m.
Corridors Turnaround Space
Maneuvering spaces measuring 1.80m×1.80m, provided every 12m or at dead ends.
Accessible Toilet Cubicle Size
An interior stall dimension of 1.80m×1.80m.
Toilet Turning Space (Outside)
An exterior clear turnaround area measuring 1.80m×1.80m.
Water Closet Center to Wall
A fixed centerline distance of 450mm from the adjacent side wall.
Toilet Seat Height
A seat height of 450mm (a minimum of 17").
Toilet Grab Bar Height
Mounted at 300mm measured from the top of the toilet seat (approximately 750mm from the finished floor).
Toilet Grab Bar Spacing
Spaced 350mm from the toilet centerline to each bar, providing a total gap of 700mm.
Lavatory Height (Amended BP 344)
A rim height of 800mm with an underneath knee clearance of 650mm.
Urinal Lip Height
A rim or lip height of 350mm to 400mm above the floor.
Toilet Emergency Button Height
Call button installed at a height between 400mm and 600mm from the floor.
Elevator Car Dimensions
An interior cab dimension of 1.20m in width by 1.40m in depth.
Elevator Door Opening
A clear door entrance opening width of 900mm.
Elevator Control Panel Height
Centered at an operating height of 900mm.
Accessible Parking Slot Dimensions
A total space of 4.00m×5.00m, which includes a 1.50m dedicated transfer area.
Parking Signage Height
Pole-mounted accessibility identification sign installed at a height of 2.20m.
Accessible Parking Allocation (1–100 Slots)
Required accessible stalls by total capacity: 1–25 slots require 1; 26–50 require 2; 51–75 require 3; 76–100 require 4.
Accessible Parking Allocation (101–500 Slots)
Required accessible stalls by total capacity: 101–150 require 5; 151–200 require 6; 201–300 require 7; 301–400 require 8; 401–500 require 9.
Accessible Parking Allocation (>500 Slots)
For 501–1000 slots: 2% of total spaces; for >1000 slots: 20 stalls plus 1 per additional 100 slots (or fraction thereof).
Accessible Hotel Rooms
2% of total hotel guest rooms must be fully accessible, with bed heights set at 500mm.
Accessible ATM and Ticket Machines
Operating controls positioned between 0.90m and 1.20m, accompanied by a clear floor space of 1.80m×1.80m.
Accessible Dining Tables
Tables configured with an overall height of 750mm, vertical knee space of 700mm, and a depth of 480mm.
Signage Centerline Height (Amended BP 344)
Signage centerline fixed at 1.50m from the finished floor (replacing the previous range).
Swimming Pool Transfer Wall Height
An accessibility transfer wall height of 450mm.
Service Animal Relief Area
A dedicated outdoor or designated facility measuring a minimum of 3sq. meters.
Auditorium / Theater Wheelchair Seating Capacity
4–50 seats: 2 WC; 51–300 seats: 4 WC; 301–500 seats: 6 WC; >500 seats: 1 WC space per additional 100 seats.
Bus Designated PWD Seating
Regular buses must allocate 5 seats; premium buses must allocate 4 seats (which may be occupied by other passengers when not in use).
Jeepney Designated PWD Seating
Requires 2 designated seats; other passengers may occupy them if vacant, yielding only to incoming PWDs if the yielding passenger can still be accommodated at the back.
Passenger Train Designated PWD Seating
Requires 6 designated seats per train car, located nearest to the entrance doors.
Airplane Designated PWD Seating
At least 2 designated seats placed near the front exit/entrance door on a per aircraft-type basis.
Batas Pambansa Blg. 344 (BP 344)
Also known as the Accessibility Law; an act enacted on February 25, 1983, to enhance the mobility of disabled persons by requiring certain buildings, institutions, establishments, and public utilities to install facilities and other devices.
R.A. 7277 Section 46 Penalties (First Violation)
A fine of not less than Fifty thousand pesos (P50,000.00) but not exceeding One hundred thousand pesos (P100,000.00), or imprisonment of not less than six (6) months but not more than two (2) years, or both at the discretion of the court.
R.A. 7277 Section 46 Penalties (Subsequent Violation)
A fine of not less than One hundred thousand pesos (P100,000.00) but not exceeding Two hundred thousand pesos (P200,000.00), or imprisonment of not less than two (2) years but not more than six (6) years, or both at the discretion of the court.
Wheelchair Standard Dimensions
Standard operating dimensions of 1.10m in length by 0.80m in width.
Wheelchair Turning Space
A clear circular turning diameter of 1.80m.
Knee Clearance (Under Tables)
A minimum vertical clearance of 0.70m underneath table surfaces.
Assembly Seating Space (Per Wheelchair)
A designated floor space measuring 0.90m in width by 1.10m in length.
Vertical Reach Limits
A reach range of 0.70m−1.20m, restricted to a maximum of 1.10m if an obstruction is present.
Horizontal Reach Limits
A forward or side reach distance between 0.50m and 0.90m.
Main Ramp Gradient
A maximum standard gradient of 1:20, with 1:15 allowed only for special cases or limited ramp lengths.
Curb Ramp Gradient
A maximum allowable slope of 1:15.
Accessible Ramp Width
A minimum clear width of 1.20m (unchanged).
Ramp Handrail Heights
Dual continuous handrails installed at both 0.70m and 0.90m above the ramp surface.
Handrail Extensions
A continuous horizontal extension of 300mm required at the top and bottom of ramps and stairs.
Railings and Handrail Diameter
A grip diameter measuring between 30mm and 40mm.
Curbs / Edge Protection
A continuous raised barrier with a minimum height of 100mm along open edges.
Stair Maximum Riser Height
A maximum vertical step rise of 150mm.
Stair Minimum Tread Width
A minimum horizontal step run of 300mm.
Tactile Warning Strips (Stairs / Hazards)
Textured warning surfaces with a depth of 600mm, installed 300mm before stairs or hazards.
Stair Width and Landing Depth
A clear stair width of 1.50m and a landing depth of 1.50m.
Door Minimum Clear Width
A minimum unobstructed opening of 900mm (0.90m).
Door Level Space (Turnaround)
A level maneuvering clear space of 1.80m×1.80m located before and extending beyond the door.
Door Hardware Height
Centered operable handles, knobs, or pulls positioned at 900mm (0.90m) from the floor.
Kick Plate Height
Protective surface plates installed across the bottom of doors to a height between 300mm and 400mm.
Vision Panel Height
Glazed panels located with a maximum of 0.90m at the bottom edge to a minimum of 1.50m at the top edge.
Corridor Minimum Width
A minimum clear walking width of 1.50m, expanding to 1.80m where two wheelchairs are required to pass.
Corridor Headroom
A minimum unobstructed vertical ceiling clearance of 2.20m.
Corridor Turnaround Space
A clear space measuring 1.80m×1.80m provided every 12m along a corridor or at dead ends.
Accessible Toilet Cubicle Size
An interior compartment measuring at least 1.80m×1.80m.
Toilet Turning Space (Outside)
A clear turning area of 1.80m×1.80m situated outside the cubicle.
Water Closet Center to Wall
A placement distance of 450mm from the center line of the toilet bowl to the adjacent side wall.
Toilet Seat Height
A finished seat height of 450mm (17” minimum).
Toilet Grab Bar Height
Mounted 300mm above the top of the seat (approximately 750mm from the finished floor).
Toilet Grab Bar Spacing
Positioned 350mm from the center line to each bar, providing a 700mm total gap between grab bars.
Lavatory Height and Clearance
A maximum counter or rim height of 800mm with a minimum underneath knee clearance of 650mm.
Urinal Lip Height
A rim lip mounted between 350mm and 400mm from the floor.
Toilet Emergency Button Height
An alarm or call button positioned between 400mm and 600mm above the floor.
Elevator Car Dimensions
A minimum cabin interior size of 1.20m in width by 1.40m in depth.
Elevator Door and Panel Specifications
A clear door opening width of 900mm and a centered control panel height of 900mm.
Accessible Parking Slot Size
Overall stall dimensions of 4.00m×5.00m, which includes a 1.50m wide transfer area.
Parking Signage Height
A pole-mounted display height of 2.20m.
Accessible Parking Ratios (1–100 Spaces)
1 slot for 1–25; 2 slots for 26–50; 3 slots for 51–75; and 4 slots for 76–100 total parking capacity.
Accessible Parking Ratios (101–500 Spaces)
5 slots for 101–150; 6 slots for 151–200; 7 slots for 201–300; 8 slots for 301–400; and 9 slots for 401–500 total parking capacity.
Accessible Parking Ratios (> 500 Spaces)
2% of total spaces for facilities with 501–1000 bays; for facilities with > 1000 bays, 20 spaces plus 1 additional space per 100 (or fraction thereof) above 1000.