Rad Protection 3 test

0.0(0)
Studied by 0 people
call kaiCall Kai
learnLearn
examPractice Test
spaced repetitionSpaced Repetition
heart puzzleMatch
flashcardsFlashcards
GameKnowt Play
Card Sorting

1/57

encourage image

There's no tags or description

Looks like no tags are added yet.

58 Terms

1
New cards

An ____ is a set of number limits that are based on risks associated with radiation exposure and sets an upper boundary dose that results in negligible risks. These limits have been incorporated into Title ___ of the code of federal regulations, Part ___

effective dose limiting system, 10,20

2
New cards

NCRP report __ is the resource basis for the effective dose limiting system.

116

3
New cards

The ___evaluates radiation biological effects and makes recommendations on an international level.

ICRP

4
New cards

The ___ reviews the ICRP recommendations and incorporates them into the national protection criteria.

NCRP

5
New cards

The ___ and ___ collect data in which the NCRP and ICRP uses to make their dose limits reports.

UNSCEAR, BEIR

6
New cards

The ___oversees the regulation of the nuclear energy industry.

NRC

7
New cards

The NRC can enter into _______ to assume responsibility for enforcing radiation protection regulations.

agreement state

8
New cards

The ___oversees the natural environmental regulation

EPA

9
New cards

The ___ regulates electronic equipment and particularly the manufacture and installation of radiographic and mammography equipment.

FDA

10
New cards

___is responsible for regulations concerning an employee’s right to know and workplace hazards.

OSHA

11
New cards

The NRC mandates a radiation safety committee with an _____overseeing the committee and the facilities radiation protection practices

Radiation Safety Officer

12
New cards

What are the responsibility of the radiation safety officer.

oversee the programs daily operation, Provide for formal review of the program each year.

13
New cards

The ____ was passed by congress in 1968 to protect the public from the hazards of unnecessary radiation exposure from electronic products.

Radiation control health and safety act

14
New cards

Major accomplishments by the act were to ensure that subsequent exposures of the exact same technical factors produce the same output this is called ______. Also the act ensured that varied ma and time combinations that yielded the same mAs had consistent output is called___

Linear and resprosity

15
New cards

the act incorporated collimation which is called _______

PBL or positive beam limitation

16
New cards

It also called for _____ backup times when using automatic exposure control

manual

17
New cards

Indicators for beam on must be _____and ______

visible and audible

18
New cards

The _______ required minimal standards for educational programs

consumer patient radiation health and safety act

19
New cards

effects that are random are considered ________. The radiation protection philosophy are based on these effects

stochastic effects

20
New cards

Effects that are based on threshold doses are considered ____

non-stochastic effects or deterministic

21
New cards

Stochastic effects are considered to be

non-threshold

22
New cards

Nonstochastic effects are considered to be

threshold

23
New cards

What is the the ALARA principle

as low as reasonably achievable and optimization

24
New cards

The tissue weighting factor indicates the _____ of the organs to radiation exposure. The ____ are the most sensitive organs.

sensitivity and gonads

25
New cards

personnel exposure monitoring is required when the worker is likely to recieve ___% or more of the annual occupational dose limit

10

26
New cards

the annual occupational effective dose limit is __rem and __mSv

50 and 5

27
New cards

the primary dosimeter should be worn _____ and should be worn ___ the apron during fluoroscopy

collar level and outside

28
New cards

for fetal monitoring secondary dosimeter should be worn at the level of the ___ and on the ____ of the apron

abdominal and beneath

29
New cards

if the hands are near the primary beam an _____ dosimeter should be worn

TLD or extremity dosimeter

30
New cards

employment records of personnel working in radiation areas should include _____

dosimeter reports

31
New cards

in choosing a dosimeter for personnel to wear what are the characteristics that the dosimeter should posses?

lightweight, durable, measure small and large exposures, inexpensive and not affected by outside influences.

32
New cards

a ________ is used to monitor radiation exposure to dosimeter during transport. This dosimeter must be kept in a _____ area

control monitor and radiation free

33
New cards

radiation _____ document deep,eye and shallow exposures.When the dose is below the measurable range fro the dosimeter reading period, then the reports will document letter___

OSL measures dose and N

34
New cards

the ___ uses a aluminum oxide as the detector measuring material.

OSL

35
New cards

when the OSL is read out by a ___ the dosimeter gives off a ____ in ____proportion to the amount of radiation received

laser and light and 1.00rem

36
New cards

The OSL can be worn up to ___ year

1

37
New cards

the OSL has 3 different filters made of ____,____,___

aluminum and tin and copper

38
New cards

Once it is read out the OSL can be _____ but not ____

reread and reused

39
New cards

what does TLD stand for

thermoluminescent dosimeter

40
New cards

the OSL is sensetive ranging from as low as ___

10 mircoSv or 1milirem

41
New cards

osl advantages:

Lightweight and durable and not affected by heat or pressure and record sensetive as low as 10 uSV (1milirem) and can be worn up to a 1 year

42
New cards

what are the disadvantages of OSL

exposure only recorded in area worn and exposure cant immediately out read

43
New cards

the ___ is the most sensitive dosimeter

OSL

44
New cards

the OSL resembles a ____

ink pen

45
New cards

the pocket dosimeter is really an ______ chamber and measures _____

ionization and wide ranges

46
New cards

the pocket dosimeter is ____ but it provides _____ readout

expensive and immediate

47
New cards

the pocket dosimeter must be ____for accurate readout

charged

48
New cards

the pocket dosimeter can measure exposure as low as ____

0mR

49
New cards

advantages of pocket dosimeter

measures wide ranges and quick and small

50
New cards

disadvantages of the pcket dosimeter are

delicate and needs to be charged and needs to be warmed up

51
New cards

the TLD snesing materal is made of

lithium fluoride

52
New cards

the TLD is an ____ in a ____ for the readout process

analyzer, laser glow curve

53
New cards

once it is readout the TLD can be ___ but not ____

reused and reread

54
New cards

the TLD can measure exposures as low as ____

1.3× 10^-6(c/kg) or 5mR

55
New cards

advantages of TLD

light weight and small and accurate and not affected by humidity or pressure and worn up to 3 months and reusable and cost effective

56
New cards

the _____ area survey meter is used to measure exposure rate with fluoroscopic equipment installations

cutie pie

57
New cards

the _____ area survey meter serves NO useful purpose in the our field

proportional counter

58
New cards

the ____ area survey meter is used to detect lost radioactive sources and is used in monitoring nuclear medicine facilities.

Geiger Muller