An ____ is a set of number limits that are based on risks associated with radiation exposure and sets an upper boundary dose that results in negligible risks. These limits have been incorporated into Title ___ of the code of federal regulations, Part ___
effective dose limiting system, 10,20
NCRP report __ is the resource basis for the effective dose limiting system.
116
The ___evaluates radiation biological effects and makes recommendations on an international level.
ICRP
The ___ reviews the ICRP recommendations and incorporates them into the national protection criteria.
NCRP
The ___ and ___ collect data in which the NCRP and ICRP uses to make their dose limits reports.
UNSCEAR, BEIR
The ___oversees the regulation of the nuclear energy industry.
NRC
The NRC can enter into _______ to assume responsibility for enforcing radiation protection regulations.
agreement state
The ___oversees the natural environmental regulation
EPA
The ___ regulates electronic equipment and particularly the manufacture and installation of radiographic and mammography equipment.
FDA
___is responsible for regulations concerning an employee’s right to know and workplace hazards.
OSHA
The NRC mandates a radiation safety committee with an _____overseeing the committee and the facilities radiation protection practices
Radiation Safety Officer
What are the responsibility of the radiation safety officer.
oversee the programs daily operation, Provide for formal review of the program each year.
The ____ was passed by congress in 1968 to protect the public from the hazards of unnecessary radiation exposure from electronic products.
Radiation control health and safety act
Major accomplishments by the act were to ensure that subsequent exposures of the exact same technical factors produce the same output this is called ______. Also the act ensured that varied ma and time combinations that yielded the same mAs had consistent output is called___
Linear and resprosity
the act incorporated collimation which is called _______
PBL or positive beam limitation
It also called for _____ backup times when using automatic exposure control
manual
Indicators for beam on must be _____and ______
visible and audible
The _______ required minimal standards for educational programs
consumer patient radiation health and safety act
effects that are random are considered ________. The radiation protection philosophy are based on these effects
stochastic effects
Effects that are based on threshold doses are considered ____
non-stochastic effects or deterministic
Stochastic effects are considered to be
non-threshold
Nonstochastic effects are considered to be
threshold
What is the the ALARA principle
as low as reasonably achievable and optimization
The tissue weighting factor indicates the _____ of the organs to radiation exposure. The ____ are the most sensitive organs.
sensitivity and gonads
personnel exposure monitoring is required when the worker is likely to recieve ___% or more of the annual occupational dose limit
10
the annual occupational effective dose limit is __rem and __mSv
50 and 5
the primary dosimeter should be worn _____ and should be worn ___ the apron during fluoroscopy
collar level and outside
for fetal monitoring secondary dosimeter should be worn at the level of the ___ and on the ____ of the apron
abdominal and beneath
if the hands are near the primary beam an _____ dosimeter should be worn
TLD or extremity dosimeter
employment records of personnel working in radiation areas should include _____
dosimeter reports
in choosing a dosimeter for personnel to wear what are the characteristics that the dosimeter should posses?
lightweight, durable, measure small and large exposures, inexpensive and not affected by outside influences.
a ________ is used to monitor radiation exposure to dosimeter during transport. This dosimeter must be kept in a _____ area
control monitor and radiation free
radiation _____ document deep,eye and shallow exposures.When the dose is below the measurable range fro the dosimeter reading period, then the reports will document letter___
OSL measures dose and N
the ___ uses a aluminum oxide as the detector measuring material.
OSL
when the OSL is read out by a ___ the dosimeter gives off a ____ in ____proportion to the amount of radiation received
laser and light and 1.00rem
The OSL can be worn up to ___ year
1
the OSL has 3 different filters made of ____,____,___
aluminum and tin and copper
Once it is read out the OSL can be _____ but not ____
reread and reused
what does TLD stand for
thermoluminescent dosimeter
the OSL is sensetive ranging from as low as ___
10 mircoSv or 1milirem
osl advantages:
Lightweight and durable and not affected by heat or pressure and record sensetive as low as 10 uSV (1milirem) and can be worn up to a 1 year
what are the disadvantages of OSL
exposure only recorded in area worn and exposure cant immediately out read
the ___ is the most sensitive dosimeter
OSL
the OSL resembles a ____
ink pen
the pocket dosimeter is really an ______ chamber and measures _____
ionization and wide ranges
the pocket dosimeter is ____ but it provides _____ readout
expensive and immediate
the pocket dosimeter must be ____for accurate readout
charged
the pocket dosimeter can measure exposure as low as ____
0mR
advantages of pocket dosimeter
measures wide ranges and quick and small
disadvantages of the pcket dosimeter are
delicate and needs to be charged and needs to be warmed up
the TLD snesing materal is made of
lithium fluoride
the TLD is an ____ in a ____ for the readout process
analyzer, laser glow curve
once it is readout the TLD can be ___ but not ____
reused and reread
the TLD can measure exposures as low as ____
1.3× 10^-6(c/kg) or 5mR
advantages of TLD
light weight and small and accurate and not affected by humidity or pressure and worn up to 3 months and reusable and cost effective
the _____ area survey meter is used to measure exposure rate with fluoroscopic equipment installations
cutie pie
the _____ area survey meter serves NO useful purpose in the our field
proportional counter
the ____ area survey meter is used to detect lost radioactive sources and is used in monitoring nuclear medicine facilities.
Geiger Muller