what is transmission
no longer fourier space
phases are kept, distances are the same
what is a CT scanner
sum of transmission images, like XRD summing waves
the finer the angles, the better the resolution of the image you produce
adjust contrast
compare XRD and CT
both use x-rays
both use data collected from different angles
XRD rotates crystal, CT scanner rotates x-ray source
both add images to get final result
CT relies on transmission through a sample
XRD relies on diffraction by a crystal (waves)
CT scanner gives 2D cross-sections that can be joined to give 3D image
crystallography gives 3D map
how does electron microscopy of protein work
technology revolution for cryo-EM: richard henderson, jacque dubochet, joachim frank
beam of electrons fired at frozen protein solution
emerging scattered electrons pass through lens to create magnified image on detector, structure can be worked out from that
solution of proteins, tiny EM grid put into liquid ethane cooled solution
analyze data using microscopy
within the grid there are carbon foils, within that is coils, see if protein gets inside
collect transmission image, from random orientations, tomograms
most important is getting accurate angles, without that you can’t get structure
transmission EM (TEM) vs light microscopy
TEM involves magnets and a detector (not eye)
electrons poorly penetrate sample, bad resolution
what must you have for cryo-em
pure sample, otherwise you have to classify each shape into its own class and you must be able to identify your protein among others or contaminants
cryo-em map not electron density map
XRD vs single particle cryo-EM
very similar
x-ray → protein crystal → diffraction pattern (fourier space) → phase determination (using fourier transformation) → electron density map (real space) → protein atomic model
electron beam → vitrified protein sample (vitreous ice) → 2D projection (collect at different orientations from particle) → orientation determination of particles (3D reconstruction/EM density map) → pseudo/atomic model
what is the workflow for single particle cryo-EM
sample of pure protein
put on tiny grids, remove excess liquid, dunk in liquid ethan (freezes faster than liquid nitrogen)
particles will be in random orientation, single particle images generated by TEM, pick particles
align them in 2D, arrange in 3D
details on sample optimization
you lose 98% of protein to the carbon grid, very few actually make it into the holes
Ice thickness must be optimized: too thin, protein won’t go into holes
too thick, contrast will be reallly bad
accurate assignment of angles is crucial
details on ice thickness
can vary in a single hole (thinner or thicker in center)
take low resolution of protein, simulate what it should look like under different orientations
projection matching with reference model, but this can create biases