Biochem Lab Practical

0.0(0)
Studied by 0 people
call kaiCall Kai
learnLearn
examPractice Test
spaced repetitionSpaced Repetition
heart puzzleMatch
flashcardsFlashcards
GameKnowt Play
Card Sorting

1/30

encourage image

There's no tags or description

Looks like no tags are added yet.

31 Terms

1
New cards

What is accuracy?

Measures how close a measured value is to the true accepted value.

2
New cards

What is precision?

measures how close a set of repeated measurements are to one another.

3
New cards

If 180 µL sample is needed, which micropipette do you prefer for higher accuracy? P-1000 or P-200?

You would use a P-200 micropipette

4
New cards

What is the function of a buffer?

to resist PH changes when small amounts of an acid or base are added to a solution.

5
New cards

Given the pKa of CAPS is 10.4. What is the good buffer range?

A good buffering range is ± 1 pKa. 9.4-11.4

6
New cards

Given the pKa of CAPS is 10.4. How could you prepare a CAPS buffer at pH 7.5?

This would not work, since 7.5 is out of the buffering (±1pKa) range

7
New cards

What is the pH of our blood?

it is between 7.3 and 7.4. Average is 7.4

8
New cards

What is the unit of A in the Beer-Lambert Law?

The unit of A, absorbance, is unitless

9
New cards

What are the four advantages of Bradford Assay for figuring out protein concentration?

fast, stable, sensitive, and affordable


10
New cards

How to do a dilution to achieve dilution factor = 4?

Combine 1 part original (stock solution) with 3 parts of diluent (water or buffer)

11
New cards

For a dilution you?

you want a dilution factor of X, you always use 1 part original sample. X-1 = dilution

12
New cards

Which protein sample is used to obtain a standard curve?

Bovine Serum Albumin (BSA)

13
New cards

Why is BSA used for a standard curve?

it is inexpensive, readily available in pure form, and reacts predictably

14
New cards

What is the function of a standard curve?

used to determine the unknown concentration of a substance in a sample by comparing its measured signal to a set of standards with known concentrations

15
New cards

In the lab, what two substrates and products of the reaction catalyzed by LDH?

LDH catalyzes the conversion of the two substrates L-Lactate and NAD+ into the products Pyruvate and NADH.

16
New cards

Why is it necessary to collect the baseline without adding enzyme?

accounts for non-enzymatic background signals. It also verifies instrument stability

17
New cards

What is the function of ammonium persulfate?

It generates free radicals and initiates the chain reactions. Can also affect the gel polymerizing time.

18
New cards

What is the function of SDS ( Sodium dodecyl sulfate)?

serves as a detergent with both a hydrophobic tail and a hydrophilic head. By binding to SDS, proteins are denatured into rod shape polypeptide chain in their primary structures, and the negative charges are evenly spread throughout the polypeptide.

19
New cards

What is the function of DTT or beta-mercatoenthanol?

both are reducing agents that break disulfide bonds between two Cys residues

20
New cards

What is the pH of the buffer to make the separating/stacking gel?

The upper part (stacking gel) has a pH of 6.8 and the lower part (resolving/separation gel) has a pH of 8.8

21
New cards

By which aspect can SDS-PAGE separate different peptides?

can separate different peptides based on their molecular weight

22
New cards

Does larger or smaller peptides migrate faster in SDS-PAGE?

A smaller peptide migrates faster

23
New cards

What is the function of the DNA marker or ladder?

serves as a set standard sized DNA molecules. We may know the size of the target segment by comparing its band position with the marker

24
New cards

Can we use 1000 V to run the electrophoresis? Why/Why not?

No, running a gel at such high voltage generates excessive heat, which destroys the gel and ruins the sample separation.

25
New cards

How to define the stationary phase and mobile phase?

The stationary phase is the fixed substance that stays in place. The mobile phase is the moving fluid that carries the sample mixture through it.

26
New cards

How gel filtration works, why do larger molecules run faster than smaller ones?

Separate molecules by size, as they pass through a column packed with microscopic porous gel beads. Larger molecules run faster b/c they are too big to enter the pores of the beads, allowing them to take a direct, shorter path straight around the beads and exit the column first.

27
New cards

What is the exclusion limit of a gel filtration column?

is the molecular mass above which molecules are completely excluded from entering the pores of the stationary phase beads

28
New cards

Why should we not vortex samples in plasmid purification?

because the sample should not be handled roughly. Vigorous mixing shears genomic DNA into small fragments.

29
New cards

What is a restriction enzyme?

A protein that cuts DNA at specific, known nucleotide sequences called recognition sites.

30
New cards

What is a palindromic sequence?

palindromic DNA sequence reads the exact same way from 5’ to 3’

31
New cards

Write a palindromic sequence

top: 5’ - GAATTC-3’

bottom : 5’-CTTAAG-3’