New cards

Pressure can be used to measure the height of liquid in a container. T/F

True

2
New cards

Flow rates of solids are determined by measuring the weight on a specified length of a conveyer belt during a given time period. T/F

True

3
New cards

The differential pressure meter can be used to measure the flow rate of a liquid, but not a gas. T/F

False

4
New cards

Most volumetric flow rate measurements are taken using an inferred method. T/F

True

5
New cards

Positive displacement flow meters are physically rotated by the fluid to develop the readings. T/F

True

6
New cards

A hydrostatic head level detector can be used to measure level within a confined and pressurized container. T/F

False

7
New cards

A rotameter is capable of reading the flow rate of a liquid or a gas. T/F

True

8
New cards

The level of a material can be determined by measuring the weight of the contents in a pressurized container. T/F

False

9
New cards

A capacitive probe is a recommended device to measure the level of mineral water in a tank. T/F

False

10
New cards

Pressure is measured as a force per unit of __________.

area

11
New cards

The accuracy of a(n) __________ is altered by atmospheric pressure fluctuations.

gage pressure measurement

12
New cards

Head is a measure of the __________.

height of a column of fluid

13
New cards

A thermocouple produces a voltage that is proportional to the __________.

difference in temperature between the hot and cold junction

14
New cards

An arrangement of several thermocouples wired in series for the purpose of increasing sensitivity is referred to as a(n) __________.

thermopile

15
New cards

Thermistors react according to the principle of __________ temperature coefficient.

negative

16
New cards

The Reynolds number is reduced if __________.

the diameter of the pipe is smaller, the viscosity of the fluid is larger, the velocity of the fluid reduces, a fluid with a lower density is used

17
New cards

The larger the diameter of a pipe, the __________ the fluid to pass through.

easier it is for

18
New cards

A Time of Flight flow meter should be placed in the pipe

at least 5 pipe diameters away from anything causing turbulence

19
New cards

In a differential pressure flow meter, the velocity of a fluid leaving the orifice plate is __________ the fluid that approaches it.

greater than

20
New cards

The __________ design is the best type of differential pressure flow meter to measure slurries.

venturi tube

21
New cards

A mass flow meter uses a __________ to determine the flow.

weight reading

22
New cards

A Coriolis flow meter is a __________ type of flow meter.

mass

23
New cards

Which type of flow meter does not use inferred readings to determine flow?

Positive displacement or Velocity

24
New cards

The formula Q=VA indicates that volumetric flow can be determined if two variables are known. These variables are A -the cross-sectional area of the pipeline, and V -the fluid __________.

velocity

25
New cards

A paddle wheel detector is a __________-type of level measurement instrument.

point

26
New cards

The differential pressure method takes measurements in a(n) __________ container.

pressurized

27
New cards

When a pressure transducer is connected to the bottom of a vessel for the purpose of measuring level, what is the actual variable being measured?

hydrostatic head pressure

28
New cards

A(n) ___ has a larger range than a ___ at which it can measure temperature.

RTD, thermistor

29
New cards

When cooled, the volume of a gas in a sealed container will ____and the pressure will __________.

remain the same, contract proportionally

30
New cards

An ultrasonic level detector is a(n) ___________-type sensor which is ideal for measuring dangerous or sterile materials because it is __________.

analog, noninvasive

31
New cards

The resistance of a(n) __________ is more linear than a(n) __________ over the temperature span of which it is capable of measuring.

RTD, thermistor

32
New cards

The method of measuring one variable to determine the value of another is referred to as __________.

an inferred measurement

33
New cards

Using load cells on a conveyor to measure solid particle flow only works for very large items. T/F

False

34
New cards

Weighing the material on a conveyor belt is an inferred method of flow measurement. T/F

True

35
New cards

what sensing elements can be used to measure the flow of solid materials on a conveyor.

LVDT, strain gauge