What is the effect of increasing the distance between the X-ray source and the image receptor?
No effect on energy; Reduce intensity
What is the primary function of the x-ray tube?
accelerate electrons from the cathode to anode
Bremsstrahlung radiation is produced when:
High-speed electrons are decelerated near the nucleus of target atoms.
All of the following are subject factors when assessing image quality, except:
Object position
Photometry is the science of the:
response of the human eye to visible light
Increasing filtration _____________ the average energy of an x-ray beam and x-ray intensity _______________.
increases; decreases
Which body habitus is small, frail, sometimes emaciated, and often seen in elderly patients?
Asthenic
Scatter radiation is:
Radiation that changes direction after interacting with matter
What is increased by added filtration?
"Effective" Energy
Surface-Guided Radiation Therapy (SGRT) primarily uses:
Optical cameras to monitor a patient's external surface
What is the purpose of image inversion in medical imaging?
Reversing grayscale values—black becomes white and white becomes black
Filters for x-ray beams are typically made or:
Aluminum
Bremsstrahlung X-ray energy is ________ proportional to its wavelength.
inversely
T/F Heat production also increases indirectly with increasing kVp (at least in the diagnostic range).
False
Which body habitus is typically big in frame and often overweight?
Hypersthenic
Cone-Beam Computed Tomography (CBCT) is commonly used for:
Image-guided patient positioning and localization
T/F Radiolucent appears darker on a radiograph.
True
What is the primary benefit of using subtraction in Digital Subtraction Angiography (DSA)?
Improves image contrast by removing background structures
X-ray intensity is __________________ to the square of the distance from the source.
Inversely proportional
Computed Radiography (CR) uses:
Imaging plates that are digitally processed
T/ F Characteristic x-rays have precisely fixed energies.
True
What is the purpose of defining a Region of Interest (ROI) in quantitative imaging?s
To measure the average pixel value for analysis
If the kVp are increased, then the electron kinetic energy will ____________.
increase
What is the result of increasing filtration in the X-ray beam?
Increase energy; Reduce intensity
Why is pixel shift used during image postprocessing?
To correct for patient motion and align images accurately
Scotopic vision is related to:
night vision
The primary purpose of SGRT is to:
Improve patient positioning and monitor patient motion during treatment
T/F Sharpness of Image Detail describes the ability to see the detail on the image.
False
All of the following are types of filtration, except:
Compounding filters
Process by which very high-energy x-rays can escape interaction with electrons and the nuclear electric field and can be absorbed directly by the nucleus is:
Photodisintegration
In multislice CT, the protocol parameter collimation is:
A combination of beam collimation and detector array size
T/F Image artifacts can typically be minimized through proper alignment.
False
The cones are:
used for photopic vision
Interfraction uncertainties refer to:
Variations occurring between treatment fractions that affect accuracy
When assessing image quality, which of the following would be considered a geometric factor?
Image Blur
Which of the following are considered X-ray interactions occurring with (body) matter? (Select 2 that apply.)
Photoelectrical absorption and Compton Scattering
Absorption of an x-ray by ionization is:
Photoelectric Effect
Which body habitus is described as "strong, active," and represents the average patient?
Sthenic
X-ray beam hardening is:
increases the # of high energy x-rays in the beam by removing the lower-energy nonpenetrating x-rays.
What is the magnification factor?
Image Size/Object Size
What is the primary purpose of x-ray beam filtration?
to filter low energy x-rays
In imaging, density generally refers to:
The degree of image blackness or brightness
In the Photoelectric Effect:
The photon is completely absorbed by an inner-shell electron
If the mAs increase, the number of projectile electrons racing towards the target _____________.
increase
Detectors are used to:
Measure and capture radiation information
How does magnification enhance image interpretation
By improving visualization and spatial resolution
Contrast resolution refers to
ability to distinguish between and to image similar tissues
Photon interacts with an outer shell atomic electron and the photon becomes redirected, or scattered, from its original path without a change in energy is
Coherent Scattering
What is the primary purpose of annotation in medical imaging
To label and identify structures within the image
Which body habitus is characterized by a thin but healthy appearance
Hyposthenic
Magnification factor =
SID/SOD
The rods are used principally for which of the following?
dim vision
What is the effect of increasing mAs on the X-ray beam?
No effect on energy; Increase intensity
Image Receptor sometimes referred to a cassette. (T or F )
F
The Inverse Square Law states that radiation intensity:
Decreases proportionally to the square of the distance from the source
T/F Air, when used as a contrast agent, is considered a positive contrast agent.
False
The Spiral Pitch Ratio in CT is the:
Table movement per rotation divided by beam width
Which of the following best refers to the digital imaging process?
Flat-panel detector
Spatial resolution refers to:
The ability to distinguish small objects that are close together
Attenuation is:
The reduction in X-ray intensity that results from absorption and scattering.
Differential absorption increases as the ___ is reduced.
kVp
The bothersome magnification can be minimized by using:
Correct answer:
larger SID
T/F: The probability of Compton scattering depends on the atomic number of the target atom.
False
X-ray quality is the output intensity of an x-ray imagining system
False
The filament in an x-ray tube:
Produces electrons through thermionic emission
Window Level controls:
The center brightness value displayed on an image
What is the relationship between x-ray intensity & mAs?
Direct relationship
Image fusion combines:
Images from different modalities into a single image set
Contrast is best defined as:
Difference in image densities between structures
What principal factors influence the shape of the x-ray emission spectrum? (Select 4 that apply.)
- Relatively thick target causing multiple interactions of projectile electrons with lower energy
-Electrons with low KE
-Low-energy x-rays are more likely to be absorbed by target results in no x-ray.
-Added filtration
Positron Emission Tomography (PET) is used to:
Measure tissue metabolic activity
Teleradiology is defined as:
practice in which radiologists remotely interpret medical images and report the results
Film/Image density refers to:
Degree of image darkness or brightness
Aperture size primarily affects:
Image brightness and field of view
Image Receptor sometimes referred to a cassette.
false
What does adjusting the window and level settings in an image allow you to do?
Expand the digital grayscale to make subtle differences visible
Image contrast describes:
The ability to distinguish structures based on differences in brightness
All of the following affect distortion, except:
Object color
Classical scatter is also known as:
Coherent scatter
List the stages of digital radiographing in order.
Capture, Coupling, Collection
Attenuation refers to:
The reduction in x-ray beam intensity as it passes through matter
Functional and Molecular MRI is primarily used to evaluate:
Physiological and biochemical tissue activity
Fluorine-18 Fluorodeoxyglucose (FDG) is:
A PET radiopharmaceutical used to assess metabolic activity
An increase in mAs which increases the number of x-rays produced, ___________ the amplitude of the spectrum.
increase
Coherent scatter results in:
Photon redirection without ionization
kV cone beam CT has a certain disadvantages versus MV cone beam CT, including: (Select 2 that apply.)
Lower dose delivered to the patient
Better contrast of soft tissue and bone
Interaction between the x-ray and the nuclear electric field that causes the x-ray to disappear and that causes two electrons - one positive and one negative - to take its place is:
Pair Production
Mag Factor is represented by which equation
Image Size/Object Size
Visibility of Image Detail is best measured by contrast resolution.
True
In CT and MRI imaging, voxel size influences
Image detail and spatial resolution
Flatfielding:
used to reduce noise & improve contrast
What happens when kVp is increased?
Increase energy; Increase intensity
A typical pelvis setup is as follows:
regular pillow, arms on chest, lower vaclok
Which of the following kV x-ray machines would be used to treat a skin cancer that is 1.5 cm thick?
Orthovoltage
An othovoltage unit would produce an energy of:
250 kV
The accelerator structure of a linear accelerator is responsible for:
Accelerating electrons using microwave energy
A cyclotron accelerates charged particles outwards from the center of a flat cylindrical vacuum chamber in a _________ pattern.
spiral
Sternal Angle of Louis is at the level of _____.
T4-T5
The umbilicus falls at __________.
L3-L4
The dome (top) of the diaphragm is considered to be at _______.
T9