contrast resolution

0.0(0)
Studied by 0 people
call kaiCall Kai
learnLearn
examPractice Test
spaced repetitionSpaced Repetition
heart puzzleMatch
flashcardsFlashcards
GameKnowt Play
Card Sorting

1/18

encourage image

There's no tags or description

Looks like no tags are added yet.

Last updated 4:26 AM on 10/4/26
Name
Mastery
Learn
Test
Matching
Spaced
Call with Kai
Chat

No analytics yet

Send a link to your students to track their progress

19 Terms

1
New cards

contrast resolution

•Is the ability to detect a structure that varies only slightly in density from its surroundings (“sensitivity” of the system)

2
New cards

How much can CT differentiate an objection within x contrast variation

0.5%

3
New cards

Low contrast resolution

is desired in CT for most examinations in order to see a density difference between the object and its background

4
New cards

•CT has the x superior contrast resolution in comparison to the other imaging modalities

most

5
New cards

FACTORS AFFECTING CONTRAST RESOLUTION

•mAs/Dose

•Pixel Size

•Slice Thickness

•Reconstruction Algorithm

•Patient Size

•Window Settings

6
New cards

how does mAs/ Dose affect the contrast

it is a direct relationship. It affects the SNR and contrast resolution

7
New cards

⬆ mAs

•⬆ the number of photons, therefore more photons to create the image, ⬆ SNR

8
New cards

what is the downside of increasing mAs

directly related to the patient dose

9
New cards

how does pixel size affect the contrast

size is proportional to the quality of the image

10
New cards

Fewer photons per pixel =

increase in noise and therefore a decrease in contrast resolution

11
New cards

slice thockness has a x relationship between slice thickness and number of photos availble to produce a iamge

linear

12
New cards

Thicker slices allow more photons to  reach the detectors; better SNR but

lower spatial resolution

13
New cards

contrast we want what in slice thickness

bigger

14
New cards

spatial resolution we want what in slice thickness

thinner

15
New cards

bigger patients cause

decrease SNR (more noise) and less contrast resolution

16
New cards

slimmer patients cause

•Less scatter produced with slimmer patients (more photons reach detectors) (also improves contrast resolution)

17
New cards

window level

set to the near average density of the object. think of it as changing the anatomy to have the optimal level in the HU scale.

18
New cards

window width

must be narrow enough so that small groups of HU are represented in shade of gray displayed.

19
New cards
<p>what was done here</p>

what was done here

they changed the window settings to further see the pathology