Vocabulary practice flashcards covering induced EMF formulas, operation, characteristics, circuit diagrams, and practical applications of separately excited, shunt, series, and compound DC generators.
Basic DC Generator Induced Voltage Equation
The fundamental relationship Eo=60Znϕ=kϕω, where Eo is induced voltage, Z is total armature turns, n is rotor rotation speed in rpm, ϕ is flux per pole, k is the induced voltage constant, and ω is rotational speed in rad/s.
Separately Excited DC Generator
A DC generator in which the field winding is powered by an independent external DC source, making the field flux ϕ constant and independent of load current so that for a fixed rotational speed, Eo and terminal voltage V12 remain almost constant with varying load.

Separately Excited 2-Pole Generator Diagram (Figure 17)
A machine diagram illustrating how external exciting current Ix fed into terminals a and b magnetizes the field coils to form the North (N) and South (S) poles, producing induced voltage Eo across armature terminals x and y.

Load Characteristic of a Separately Excited Generator (Figure 24)
A curve showing terminal voltage E12 versus load current I, demonstrating a slight downward slope described by V12=Eo−Ro⋅I where voltage decreases from 100V at no load to 90V at 10A due to armature internal resistance Ro.

Flux per Pole versus Exciting Current Curve (Figure 18a)
A plot depicting magnetic flux per pole (in per-unit, p.u.) versus exciting current Ix, showing an initial linear magnetic rise up to point a, the knee and rated flux (1.00p.u. at 1A) at point b, and magnetic saturation leading toward point c.

Saturation Curve of a DC Generator (Figure 18b)
An open-circuit magnetization characteristic curve showing induced voltage Eo versus exciting current Ix at fixed speed, demonstrating a linear initial rise up to rated voltage of approximately 120V at 1A before entering the saturation region.

Shunt DC Generator (Figure 19)
A self-excited generator configuration where the field winding is connected in parallel (shunt) across the armature winding, using its own output voltage across terminals x and y to establish the exciting current Ix.
Voltage Drop Mechanism in Shunt DC Generators
A four-step cumulative voltage drop process: an increase in load current increases armature current Ia, raising internal resistance drop (V=E−IaRa); the resulting decrease in terminal voltage V reduces field current (If=RfV) and field flux Φ, causing generated EMF E to drop (E∝Φ) and terminal voltage to decline even further.

Series DC Generator (Figure 2)
A generator configuration in which the field winding (Rfse) is wired directly in series with the armature and the load, resulting in the series field carrying the full load current (If=IL).
Terminal Voltage Characteristic of a Series DC Generator
The behavior wherein an increase in load current IL increases field current If and field flux Φ, increasing generated EMF E (E∝Φ); because the increase in E outweighs the internal IaRa drop, terminal voltage V=E−IaRa net increases with load.

Long Shunt DC Generator (Figure 5)
A compound DC generator circuit layout where the shunt field winding (Rfsh) is connected across the outer terminals, placing it in parallel with the series combination of the armature and the series field winding (Rfse).
Compound DC Generator
A generator combining two separate field windings: a shunt field connected in parallel with the armature and a series field connected in series with the load, designed to balance and stabilize voltage under changing loads.
Cumulative Compounding Voltage Stabilization
A design where load current increases series field current (Ise=IL) and series flux (Φse∝IL), raising total flux (Φ=Φsh+Φse) and generated EMF (E∝Φ) to precisely compensate for armature resistance drop and armature reaction, keeping terminal voltage nearly constant.
Voltage Booster
A specialized application of series DC generators where the machine is placed in series with electrical feeders to automatically raise terminal voltage and compensate for line resistance drops as transmission load current increases.
Applications of Separately Excited DC Generators
Used where precise and stable voltage or speed regulation is required, such as in research laboratories, testing and calibration setups, and DC motor speed control; rarely used in broader industry due to the high cost and complexity of an external DC supply.
Applications of Shunt DC Generators
Used for lighting systems, battery charging, and general laboratory DC power supplies where loads are light to medium and can tolerate minor voltage variations, but unsuitable for heavy loads due to progressive voltage drop.
Applications of Compound DC Generators
Used in DC power distribution systems, elevators, cranes, hoists, workshops, and factories where sudden, heavy, and variable loads switch on and off and require a stable, constant terminal voltage.
Efficiency Equation of a DC Generator
The formula η=PinPout×100=Pout+Parmature+Pf+other lossesPout×100, where electrical losses are calculated using P=RI2.