TRAP PRIMER
PROTECTION FOR DRAINS OR TAPS SUBJECT TO INFREQUENT USE
TRAP PRIMER
AN AUTOMATIC DEVICE THAT INJECTS A SMALL AMOUNT OF WATER INTO THE TRAP EVERY TIME THERE IS A PRESSURE DROP IN THE SYSTEM
TRAP SEAL LOSS
TERM USED WHEN WATER SEAL ESCAPES FROM THE P-TRAP
SIPHONAGE
RESULT OF MINUS PRESSURE IN THE DRAINAGE SYSTEM
DIRECT OR SELF-SIPHONING
OCCUR IN UNVENTILATED TRAPS WHICH SERVES AS OVAL BOTTOM FIXTURES LIKE LAVATORIES OR SLOP SINK
SELF-SIPHONING
CREATED WHEN A RAPID FLOW OF WATER PASSESS THROUGH THE PIPE
INDIRECT OR MOMENTUM SIPHONING
RESULT OF MINUS PRESSURE IN THE PIPE CREATED BY HEAVY DISCHARGE OF WATER FROM A FIXTURE INSTALLED ON A LINE SERVING ANOTHER FIXTURE AT A LOWER FLOOR
CAPILLARY ACTION
DRAINING OF WATER SEAL CAUSED BY FOREIGN OBJECTS LIKE THREAD OR STRING SUSPENDED
1 FU
MAX. TRAP LOADING OF 32 MM PIPE SIZE
3 FU
MAX. TRAP LOADING OF 38 MM PIPE SIZE
4 FU
MAX. TRAP LOADING OF 51 MM PIPE SIZE
6 FU
MAX. TRAP LOADING OF 76MM PIPE SIZE
8 FU
MAX. TRAP LOADING OF 102 MM PIPE SIZE
WITHOUT LADDERS
EACH INTERCEPTOR OR CLARIFIER SHALL BE READILY ACCESSIBLE __________
GREASE TRAPS
______ MAY BE INSTALLED IN RESTAURANTS, CAFES, LUNCH, COUNTERS, HOTELS, FACTORY OR SCHOOL KITCHENS
GREASE TRAP
___ IS NOT REQUIRED FOR INDIVIDUAL DWELLING UNITS OR ANY PRIVATE LIVING QUARTERS
1.3 L/S TO 3.4 L/S
RATE OF FLOW OF INDIVIDUAL GREASE TRAP
4 FIXTURES
MAX. FIXTURES TO BE DISCHARGED INTO 1 GREASE TRAP
1.2 M
MAX. HORIZONTAL DISTANCE BETWEEN THE FIXTURE OUTLET AND THE GREASE TRAP
51 MM
WATER SEAL FOR GREASE TRAP
0.75 M
MAX. VERTICAL TAILPIECE OR DRAIN BETWEEN FIXTURE OUTLET AND THE GREASE TRAP
18 KG
GREASE TRAP RETENTION CAPACITY OF 1 FIXTURE CONNECTED
23 KG
GREASE TRAP RETENTION CAPACITY OF 2 FIXTURE CONNECTED
32 KG
GREASE TRAP RETENTION CAPACITY OF 3 FIXTURE CONNECTED
45 KG
GREASE TRAP RETENTION CAPACITY OF 4 FIXTURE CONNECTED
12.7 MM
LAUNDRY EQUIPMENT THAT DOES NOT HAVE INTEGRAL STRAINER MUST HAVE AN INTERCEPTOR WITH A WIRE BASKET THAT WILL PREVENT PASSAGE OF ____ MM OR LARGER SOLIDS
SAND INTERCEPTORS
___ ARE REQUIRED WHENEVER THE DISCHAGE MAY CONTAIN SOLIDS HEAVIER THAN WATER THAT WOULD BE HARMFUL TO DRAINAGE SYSTEM
1 SAND INTERCEPTOR
MULTIPLE FLOOR DRAINS MAY DISCHARGE __ SAND INTERCEPTOR
BAFFLE
SAND INTERCEPTOR SHALL HAVE AN INTERIOR __ FOR THE SEPARATION OF 2 SECTIONS
76 MM
MIN. INLET AND OUTLET PIPE SIZE.
OUTLET PIPE SIZE SHALL BE THE SAME SIZE AS THE INLET SIZE