1/241
Looks like no tags are added yet.
Who is/are must accept responsibility for workplace?
Individual & Organization
Must ultimately assume responsibility for his or her health and safety.
THE ROLE OF THE INDIVIDUAL
Individuals who do not follow the rules or who use the equipment improperly suffer from?
Injury
Everyone has the responsibility to ensure that the workplace is?
Free of danger
Everyone has the responsibility to ensure the worker is?
Protected from hazards
Who are the final arbitrators of acceptable risk and responsible for performing their work in a safe manner?
Employees
The role of the individual is a shared responsibility by?
Society & Employer
Obligated both morally and legally to see that employees have the training, support, equipment, workload, resources, environment, and oversight necessary to perform in a safe and secure manner.
THE ROLE OF THE EMPLOYER
Who must be committed to enforcing workplace safety?
Workers & Employers
Safety rules and procedures are meant for whom?
Workers
Safety rules and procedures are meant for workers because?
It's for protection
Most of the hazards found in the laboratory are common to all work sites: fire hazards, faulty electrical equipment, poor ventilation, blocked entrances and exits, hazardous clutter, poor lifting and handling techniques, and unmet building safety requirements.
HAZARDS IN THE WORKPLACE
Laboratory workers must also deal with chemicals, compressed gas, infectious material, toxic waste, and potentially dangerous machinery.
HAZARDS IN THE WORKPLACE
Laboratory workers are also particularly vulnerable to?
Pathogens in blood & body fluids.
Very first place in which safety factors should be considered is in the design and layout of the building and laboratory.
STRUCTURAL REQUIREMENTS
Errors made at this stage of the management plan can be extremely costly to correct.
STRUCTURAL REQUIREMENTS
What dictates most basic facility design features in STRUCTURAL REQUIREMENTS?
National
State
Local fire & safety building codes
These structural safety rules involve:
Building materials
Storm damage control
Fire prevention
Firefighting systems
True or Flase: the number and location of parking spaces have safety implications.
True
True or Flase: laboratory should be designed to minimize any exposure to hazardous material through its work-flow processes.
True
ISSUES to be addressed through:
Floor plan layout and Workspace design
ISSUES TBA:
Separation of nontesting functions, such as clerical and administrative offices by means of?
structural barriers and control of traffic patterns
ISSUES TBA:
Delivery and storage of potentially hazardous chemicals, such as:
flammables and corrosive materials.
ISSUE TBA:
processing of specimens, from their ______ and ________ in the laboratory to their ______ delivery to the testing site.
collection; arrival; final
ISSUE TBA:
Ventilation back-up plan is especially critical in sections such as:
Hematology & Microbiology
The hemtology and microbiology sections should have direct access to what, in cases of emergency?
Outside venting (windows & fans)
The hematology and microbiology sections have unusually:
Heavy connncentrations of chemical & biological material.
ISSUE TBA:
Location, ease of use, and rapid availability of any special safety equipment such as:
fume hoods, decontamination facilities, and first-aid stations.
separation of nontesting functions
ISSUES to be addressed through the floor plan layout and workspace design
delivery and storage of potentially hazardous chemicals
ISSUES to be addressed through the floor plan layout and workspace design
processing of specimens
ISSUES to be addressed through the floor plan layout and workspace design
ventilation back-up plan
ISSUES to be addressed through the floor plan layout and workspace design
location, ease of use, and rapid availability of any special safety equipment
ISSUES to be addressed through the floor plan layout and workspace design
ISSUE TBA must be an integral part of?
Building & layout plan (each area of the lab)
FIRE PREVENTION & SAFETY topics:
general fire prevention plans
storage and handling of flammable substances
fire-fighting strategies
Fire has 3 ingredients
FIRE PREVENTION PLANS
What are the 3 ingredients of fire?
Ignition source
O2
Fuel
keeping flammable substances in separate rooms and storage cabinets
MAIN FIRE PREVENTION STRATEGIES
using fire-resistant building products, explosionproof refrigerators, and hoods
MAIN FIRE PREVENTION STRATEGIES
performing procedures that result in highly combustible reactions under water or in a vacuum chamber
MAIN FIRE PREVENTION STRATEGIES
The most obvious method for preventing fire is to control the union of fuel and ignition sources.
HANDLING OF FLAMMABLE SUBSTANCES
The most obvious method for preventing fire is to control the union of:
fuel & ignition source
Histology and Special Chemistry use flammable chemicals such as?
Methanol & Xylene
Methanol & xylene causes what probems in reagents?
Bench & bulk storage
NFPA
National Fire Prevention Association
Lab with an area per 5000 square feet, max of 10 gallons of flammable liquids can be used/stored in?
open
outside of a safety room
cabinet
safety can
Lab with an area per 5000 square feet, max of 60 gallons of flammable liquids can be used/stored in?
Safety cabinet
If a safety cabinet or room is not available, up to 25 gallons may be stored in?
NFPA-approved safety cans
Safety cans must be used for more than:
1 pint of class A flammables
1 quart of class B flammables
1 gallon of most other flammables
Examples under 1 gallon of most other flammables
xylene
mineral oil
Examples under 1 quart of class B flammables
acetone
ethanol
methanol
Examples under 1 pint of class A flammables:
ether
isopentane
should be stored separately from other flammable material.
Flammable gas cylinders
Despite all precautions, fire remains a leading cause of death in?
workplace
Health care facilities are especially vulnerable because of:
Nature of work and clients
(3) FIRE-FIGHTING STRATEGIES
construction
firefighting equipment
training and practice
Construction:
What are the 4 major elements of fire?
structure of a building
materials used for construction
layout plan for entrances and exits
storage of flammable materials
The major elem. of a fire are crucial in the quick:
isolation and extinction of fire
number one cause of fire death:
smoke inhalation
Building codes generally require a fireresistance rating of at least ____ for walls around high-risk areas.
2 hours
Codes also require that highly explosive substances (ether & compressed flammable gas) be stored in a room with at least one:
outside wall and a direct vent
Many fire-fighting features are designed directly into the ______of the building.
construction
Fire-fighting Equipment (features) require these 4:
fire-resistant building materials
automatic sprinklers
self-closing doors
fire hydrants
Most of the furniture and fixtures used in a hospital or laboratory must also meet strict ______.
fire- and smoke-retarding standards
The number, kinds, and location of these fire-fighting items should be based on:
the work done
The 4 classes of fire are grouped according to ____ & _____ of the fire, and the type of _____ material needed to be extinguished.
nature; source; material
fires are the most common
Class A
usually started by the ignition of such material as paper and wood (ordinary combustibles).
Class A
Class A is extinguished with?
Water
consist of flammable liquids, such as alcohols, gases, and solvents.
Class B
Class B is extinguished with?
Dry chemicals (powder) or CO2
Dry chemicals (powder) or CO2 are used to what?
Smother fire by depriving oxygen
Fires caused by electrical malfunctions.
Class C
Class C extinguishers uses what?
Dry chemicals (powder) or CO2
Foam extinguishers can only be used on?
Class A & B fires
fires involve combustible chemicals or metals.
Class D
Example of combustible chemicals or metals under class D:
sodium & magnesium
Requires highly specialized extinguishers or bulk materials (sand, for control)
Class D
Fires from commercial cooking equipment.
Class K
What extinguisher is used for class K?
Wet chamical agent (potassium-based agents)
Orientation and in-service training should cover all aspects of the fire plan.
Training & Practice
individual hands-on training in the use of:
fire extinguishers
fire blankets
emergency eyewash and shower stations
fire isolation techniques
Frequent and comprehensive drills with training in assisting patients:
identifying fires
sounding the alarm
fighting fires
evacuating according to emergency plans
when to fight a fire and when to abandon the site by establishing smoke barriers (i.e., shutting windows and doors) until help arrives.
Decision-making strategies
making sure help is on the way before taking any other action, particularly in situations in which the person may be working alone.
Sounding the alarm
Techniques for when personal garments catch fire
Rollign on the floor
assisting a person on fire to smother the flames and as a shield when making an escape
Fire blankets
locations throughout the building to exit
Evacuation plan
Electrical equipment and wiring present ___ MAJOR HAZARDS in the laboratory
2
Electrical equipment and wiring present TWO MAJOR HAZARDS in the laboratory:
physical harm from shocks or burns when a person comes into contact with an electrical source.
dangers from fire caused by heat and sparks generated by malfunctioning wiring or equipment.
dealing with electrical problems requires constant ______
vigilance
no extension cords or outlet adapters.
SAFEGUARDS (recc. by NFPA)
All equipment should be checked for compliance with electrical safety standards upon arrival or before being placed into use.
SAFEGUARDS (recc. by NFPA)
Electrical safety checks should be part of the laboratory preventive maintenance programs for each piece of equipment. (yearly examination)
SAFEGUARDS (recc. by NFPA)
These checks should review the power needs of the laboratory and make certain that there are adequate electrical receptacles.
Electrical safety checks
Circuit breakers should be conveniently located and labeled in case of a major water spill or other accident requiring that power be cut off immediately.
SAFEGUARDS (recc. by NFPA)
Electrical equipment should not be used in areas with flammable materials because of sparks or ignitions, unless the equipment have been checked and determined to meet the standards necessary to be certified as explosion-proof.
SAFEGUARDS (recc. by NFPA)
Electrical safety should be part of the orientation and educational program of the laboratory
SAFEGUARDS (recc. by NFPA)
WATER SPILLS:
All electrical apparatus affected by the water or wet spill should be unplugged or the power shut off at the ______.
circuit breaker
WHAT STEP IN WATER SPILLS?
All electrical apparatus affected by the water or wet spill should be unplugged or the power shut off at the circuit breaker if the person will be placed at risk by disconnecting a single piece of equipment.
Step 1