1/21
Looks like no tags are added yet.
Name | Mastery | Learn | Test | Matching | Spaced |
---|
No study sessions yet.
Common P Trap
2” deep water seal
Deep Seal P Trap
4” deep water seal
Stand Trap
for slop sink, fixture built low in the ground
3
Traps Required: 1 trap may serve
how many single compartments sink with the same depth
0.75
Traps Required: 1 trap may serve
3 lavatories adjacent to each other not more than _m apart
0.6
Traps Required: 1 trap may serve
in no case any tailpiece or connections shall exceed _m long
51 mm (2”)
Minimum trap seal deep
102mm (4”)
Maximum trap seal deep
30 mins
Grease Interceptor retention time
24 hours
Septic tank retention time
1
Grease Traps
Required Flow - 20 gpm
Grease Retention Capacity - 40 lbs
2
Grease Traps
Required Flow - 25 gpm
Grease Retention Capacity - 50 lbs
3
Grease Traps
Required Flow - 35 gpm
Grease Retention Capacity - 70 lbs
4
Grease Traps
Required Flow - 50 gpm
Grease Retention Capacity - 100 lbs
Sand Interceptor
2 sq. ft
610 mm depth min
Oil Separators
610 mm depth
457mm water seal depth
2%
Slope of <100 mm diameter pipe for sewer
1%
Slope of 150 mm diameter pipe for sewer
0.5%
Slope of >200 mm diameter pipe for sewer
22 ½
1/16 bend in degrees bend
45
1/8 bend in degrees bend
60
1/6 bend in degrees bend