Comprehensive vocabulary flashcards covering the definitions, hardware components, circuit types, detector mechanisms, zoning, signalling methods, and IS 199 standards from Intruder Alarm Systems Lecture 1.
Intruder Alarm System
An electrical system designed to detect and signal the presence, entry, or attempted entry of an intruder into protected premises.
Control Panel
The central processing unit or brain of the alarm system, housing a PCB with a microprocessor, standby battery, field wiring terminals, and programmable settings.
Remote Keypad (RKP)
A peripheral unit used to set and unset the system, enter exit/entry codes, and access engineer mode using an engineer code for programming parameters and conducting tests.
Normally Open (NO) / Open Loop Circuit
A detection circuit where contacts remain open during normal conditions with no current flowing; an alarm sounds when a contact closes. It is unsupervised and insecure because cutting the wire prevents alarm activation.
Normally Closed (NC) / Closed Loop Circuit
A preferred detection circuit where contacts are wired in series and remain closed during normal state, allowing continuous current to hold a relay energized; an opening contact interrupts supply, de-energizes the relay, and sounds the alarm.
Double Pole (4-Wire System)
A wiring scheme utilizing a 4-core cable where two wires form a positive (+ve) alarm loop and two wires form a negative (−ve) tamper loop of opposite polarity.
Tamper Circuit
A 24-hour constantly active circuit that generates an internal sounder alarm when unset and a full alarm when set, triggering upon cover removal via microswitch, cable cuts, loose connections, or excessive unauthorized keypad entries.
Line Monitoring (End of Line / EOL)
A fully supervised circuit configuration in which the control panel continuously measures loop impedance, triggering an alarm on any change in magnitude or direction.
Diode + EOL Monitoring Method
A line monitoring technique where continuity diodes short out randomly opening contacts in unarmed daytime mode, and armed night mode reverses polarity so blocking diodes force current through contacts and an end-of-line resistor.
Internal Shunt Resistor
A built-in resistor wired in parallel across a detector's contacts in modern 2-wire systems; opening the contact adds the resistor to the circuit, enabling the panel to identify the specific detector type by its resistance value.
Magnetic Contact (Reed Switch)
A perimeter device consisting of a reed switch placed on a static frame and a magnet placed on a moving sash or door; opening the door moves the magnet away, causing the reed switch to open and trigger an alarm.
Pressure Mat
A normally open trap protection device placed under carpets, rugs, or staircases, consisting of two thin conductive plates separated by high-resistance globules that make contact when stepped on.
Inertia / Shock Sensor
A perimeter or shell protection device containing a gold-plated ball seated between contacts; physical impact or vibration moves the ball to momentarily open the circuit and trip the alarm.
Pulse Count
A programmable setting from 1 to 9 on an inertia sensor or control panel that defines how many vibration impacts must occur within a timeframe to trigger an alarm, preventing false alarms from environmental flexing.
Vibration Detector
A mechanical sensor containing a vertically suspended leaf spring with a weight and moving contact at the bottom, which separates from a fixed contact on the casing upon movement or vibration.
Passive Infra-Red (PIR) Detector
A trap detector that generates no energy of its own but uses a Fresnel lens to focus infrared radiation emitted by objects onto a sensor, detecting rapid temperature changes as an intruder crosses detection zones.
Fresnel Lens
An optical lens mounted on the front of a PIR detector to focus infrared radiation from multiple coverage zones onto the PIR sensor face.
Infra-Red Beam (Active IR)
A barrier detection device comprising an infrared transmitter positioned opposite a receiver; breaking the continuous light beam generates an alarm condition.
Ultrasonic Detector
A volumetric sensor that transmits high-frequency sound above 30kHz to establish a stabilized standing wave pattern, triggering an alarm when intruder motion alters the frequency.
Glass Break Detector
A shell protection device utilizing an acoustic microphone or piezoelectric sensor to detect and analyze the characteristic shock frequencies (3-5kHz) associated with shattering glass.
Microwave Detector (Doppler Effect)
A volumetric sensor that transmits microwaves and evaluates reflections; relative movement causes a frequency shift via the Doppler Effect, which triggers an alarm.
Perimeter Protection
Security detection applied to the external boundary or fence line of a property to detect unauthorized persons entering onto the site.
Shell Protection
Security detection focused on the external walls, doors, and windows of a building to detect an intruder's attempt to penetrate the physical building structure.
Trap Protection
Internal volumetric or spot detection placed in passageways, staircases, and hallways to detect movement once an intruder has already penetrated the building.
Entry/Exit Zone
A designated timed zone allowing occupants to leave after setting and enter to disarm without causing an immediate alarm; limited to a maximum of 3 detection devices.
Personal Attack (PA) Zone
A 24-hour continuously monitored alarm channel operated by manual hand or foot buttons, designed to trigger an audible or silent panic alarm regardless of system set status.
Duress Signalling
The transmission of a silent panic alarm to a central monitoring station via a digital communicator when a user is forced to enter a specific distress code under threat.
Walk Test
An operational test mode that allows an engineer or user to test every detector without arming the system, generating an audible tone and indicator each time a device trips.
Zoning
The practice of dividing a building's security system into separate allocated sectors to pinpoint alarm locations, enable part-setting, and simplify maintenance and fault finding.
Self Activating Bell (SAB)
An external sounder unit fitted with an internal rechargeable backup battery and a hold-off relay; if the panel supply cables are cut, the relay de-energizes and connects the internal battery to sound the bell.
Digital Communicator
A remote signalling device wired to a telephone line that automatically dials pre-programmed telephone numbers to send coded signals or recorded speech messages on alarm activation.
Shunt Lock
A key-operated mechanical lock incorporating an electrical switch that isolates a portion of an alarm circuit to allow authorized access without setting off the alarm.
IS 199
The standard regulating intruder alarm installations, establishing device limits per zone, battery backup times, audibility thresholds, sounder cutoff intervals, and mandatory maintenance periods.
components of a intruder alarm system are
Detection Devices
Signalling Devices
Control Panel (brain - PCB, microprocessor, battery, programmable)
Keypad / RKP (set/unset, programming, engineer mode)
Cables
External Sounder (Bell Box) Tamper and Power Protection
Features an internal rechargeable backup battery to provide power if the main ELV cable is cut, along with two tamper switches that initiate a full alarm if the housing is opened or pried from the wall.
Audibility and Flash Rate Specifications for External Sounders
Operates at an audibility level of 100-120dB (with an IS 199 standard minimum of 70dB at 3m) and incorporates a strobe light flashing at 60/min.
Mandatory Duration Limits for External Sounder and Strobe
The siren must be silenced automatically after a minimum of 15min and a maximum of 30min, while the visual strobe must continue flashing for at least 60min until manually reset.
SAB Hold-Off Supply Function
Supplies +12V and 0V from the control panel to maintain the internal backup battery charge and continuously energize relay RL1, holding contact RL1/1 open to disconnect the battery from the sounder during normal conditions.
Role of Resistor R1 in an SAB
Limits the charging current for NiCad backup batteries, whereas it is omitted for lead-acid batteries because they are float-charged directly across the hold supply.
SAB Alarm Activation Method
Occurs when the control panel applies 0V to the trigger terminal (negative trigger), which initiates the sounder.
SAB Supply Failure Response and Role of Diode D1
Loss of the hold-off supply de-energizes relay RL1 so that contact RL1/1 closes and powers the sounder directly from the internal battery; diode D1 prevents the battery from latching the relay back open.
SAB Strobe Circuit Independence
Driven by an independent output circuit from the sounder, ensuring visual strobe flashing can continue long after the sounder cutoff interval expires.
Xenon Tube Operation in Intruder Alarms
A gas-filled glass tube that produces a brilliant flash when a high voltage discharges through it via an integral circuit, capable of being integrated directly into a standard or translucent bell box.
Rotating Beacon
A visual signalling device that produces a sweeping beam by using a parabolic reflector circling a stationary lamp, which may require relay control due to the current draw and size of its motor.
Circuit Configuration for Visual Signalling Devices
Visual devices are wired to dedicated outputs separate from audible sounders, allowing visual indication to continue long after sounder timer cutoff limits expire.
Digital Communicator
A remote signalling device connected to the telephone network that automatically dials at least 3 pre-programmed numbers to transmit coded signals or stored speech messages upon alarm activation until a response is received.
Central Monitoring Station (CMS)
A secure facility manned 24hours a day that monitors transmitted alarm signals (such as PA or intrusion) and determines the appropriate response, including notifying emergency authorities like the Gardaí.
Keyholding
A security service where the alarm installation company securely retains keys to the protected property and dispatches an engineer to attend the premises upon alarm activation, typically charged via an annual fee.
Shunt Lock
A key-operated door lock with an integral switching device that bypasses a portion of an alarm circuit to allow authorized personnel access without triggering an alarm.