Lighting: WATER SUPPLY & WASTEWATER SYSTEMS

0.0(0)
Studied by 0 people
call kaiCall Kai
learnLearn
examPractice Test
spaced repetitionSpaced Repetition
heart puzzleMatch
flashcardsFlashcards
GameKnowt Play
Card Sorting

1/34

encourage image

There's no tags or description

Looks like no tags are added yet.

35 Terms

1
New cards

Big Idea

Water systems bring safe water into a building and safely remove wastewater. Interior designers coordinate plumbing locations, fixture types, wet walls, reuse strategies, and finish protection.

2
New cards

Properties of water

  • Water (H₂O) dissolves many substances, transports waste, supports life, and has a high specific heat capacity.

  • Example: Water can store heat in hydronic heating systems and solar thermal storage.


3
New cards

Hydrologic cycle

  • Water continuously moves through evaporation, transpiration, condensation, precipitation, infiltration, and runoff.

  • Example: Rain falls on a site, infiltrates soil, or runs into storm drains; some water evaporates back into the atmosphere.


4
New cards

Rainwater

  • Water collected from precipitation.

  • The notes describe it as naturally low in dissolved minerals and slightly acidic, around pH 5.

  • Example: A rainwater harvesting system collects roof runoff for approved non-potable uses after suitable treatment.


5
New cards

Surface water

  • Water in rivers, lakes, and reservoirs.

  • It is exposed to runoff and contamination.

  • Example: A municipal water plant may treat river water before it becomes potable.


6
New cards

Groundwater

  • Water stored underground in saturated soil or rock formations.

  • Example: A rural home may draw water from a well tapping an aquifer.


7
New cards

Aquifer

  • An underground permeable layer that stores and transmits groundwater.

  • Example: A drilled well can reach an aquifer that supplies household water.


8
New cards

Aquiclude

  • A relatively impermeable layer that restricts groundwater movement.

  • Example: A clay or rock layer can limit the movement of groundwater between zones.


9
New cards

Water table

  • The upper surface of the saturated groundwater zone.

  • Example: A shallow water table can affect basement moisture and site drainage.


10
New cards

Shallows vs. Deep wells

  • The supplied notes classify shallow wells as under 25 ft and deep wells as over 25 ft.

  • Shallow wells are more exposed to surface contamination.

  • Example: A well near a septic field or runoff area needs careful site evaluation and testing.


11
New cards

Positive displacement pump

  • Moves a fixed volume of liquid during each mechanical cycle.

  • Example: A metering pump can deliver a controlled quantity of chemical treatment.


12
New cards

Dynamic pump

  • Adds velocity to a moving fluid, commonly using an impeller.

  • Centrifugal pumps are a common type.

  • Example: A centrifugal pump circulates water through a building system.


13
New cards

Portable water

  • Water treated, tested, and certified as safe for drinking and cooking.

  • Example: A drinking fountain must be connected to an approved potable-water supply.


14
New cards

Turbidity (NTU)

  • A measure of water cloudiness caused by suspended particles.

  • Example: Cloudy source water may need clarification and filtration before disinfection.


15
New cards

pH

  • A scale from 0 to 14 showing acidity or alkalinity.

  • 7 is neutral.

  • Example: Water outside the suitable pH range can contribute to corrosion or treatment problems.


16
New cards

Hardness

  • Dissolved calcium and magnesium that can form mineral scale and reduce soap lather.

  • Example: Hard water can leave white deposits on faucets, shower glass, and water heaters.


17
New cards

Biochemical oxygen demand (BOD)

  • The amount of dissolved oxygen microorganisms need to break down organic pollution.

  • Example: High BOD indicates more biodegradable organic matter and can reduce oxygen available to aquatic life.


18
New cards

Memory sequence

O-S-F-D-S = Oxidation → Sedimentation → Filtration → Disinfection → Softening.

19
New cards

Oxidation

  • Air or an oxidizing process helps break down some organics and convert iron/manganese into forms that can be removed.

  • Example: A treatment plant aerates water so iron can oxidize and be filtered out.


20
New cards

Sedimentation

  • Water is held so suspended particles settle.

  • Coagulants such as alum can help small particles clump together.

  • Example: After coagulation, heavier floc settles to the bottom of a clarifier.


21
New cards

Filtration

  • Water passes through media such as sand, gravel, activated carbon, or diatomaceous earth to remove particles.

  • Example: A filter removes remaining suspended matter after sedimentation.


22
New cards

Disinfection

  • A process such as chlorination or ozonation inactivates harmful microorganisms.

  • Example: Chlorine can leave a residual in distribution water; ozone does not leave the same protective residual.


23
New cards

Softening

  • Treatment removes hardness-causing calcium and magnesium, often through ion exchange.

  • Example: A softener can reduce scale buildup on plumbing fixtures and water heaters.


24
New cards

Gray Water

  • Wastewater from bathroom lavatories, showers, and laundry, excluding toilet sewage and kitchen wastewater in the supplied definition.

  • May be reused for approved non-potable uses.

  • Example: A dual-plumbing system may send treated shower water to toilet flushing or landscape irrigation.


25
New cards

Black Water

  • Wastewater containing toilet sewage and fecal matter.

  • The supplied notes also include food sewage.

  • Example: Toilet discharge enters the sanitary wastewater system.


26
New cards

Separate drainage systems

  • Sanitary wastewater and stormwater are carried in separate networks.

  • Example: Roof drains should not be connected to sanitary sewer piping where code requires separation.


27
New cards

Soil pipe

  • Pipe carrying discharge containing human waste from a water closet.

  • Example: The toilet connects to a soil pipe.


28
New cards

Waste pipe

  • Pipe carrying wastewater from fixtures without human waste.

  • Example: A lavatory or shower drain connects to a waste pipe.


29
New cards

Stack

  • A main vertical soil, waste, or vent pipe extending through the building, often through the roof.

  • Example: A plumbing stack serves fixtures on several floors.


30
New cards

Septic system

  • On-site wastewater treatment commonly used where public sewer is unavailable.

  • Solids settle and are digested in a tank.

  • Liquid effluent moves to a leaching field.

  • Example: A rural home may use a septic tank and soil absorption field.


31
New cards

Color codes for pipes

  • Cold water: Blue.

  • Hot water: Red.

  • Greywater (showers, sinks, laundry): Purple when designated for reuse.

  • Blackwater/sanitary waste: Labeled sanitary.

  • Vent: Labeled vent.

  • Stormwater: Labeled storm.

  • Natural gas: Yellow.

  • Fire sprinkler: Red.

  • Recycled water: Purple.


32
New cards

Critical numbers

  • Earth's surface covered by water: 70%.

  • Water that is salty or frozen: More than 97%.

  • Shallow well: Less than 25 ft.

  • Deep well: More than 25 ft.

  • Potable turbidity: 5 NTU or less.

  • Potable pH: 6.5–8.5.

  • Rainwater pH in notes: About 5.

  • Ideal hardness in notes: 60–120 mg/L.

  • Potable BOD in notes: 4 mg/L or less.

  • Sedimentation: At least 24 hours, as listed in notes.

  • Chlorination in sewage treatment: 15–30 minutes.


33
New cards

LEED and drought-resilient buildings

  • Plan reuse systems to reduce demand for potable water.

  • Example: Dual plumbing can route treated gray water from showers and bathroom sinks to toilet flushing or irrigation.

  • The supplied notes estimate 30–40% potable-water savings for the described strategy.


34
New cards

Protecting finishes in hard water regions

  • Hard water can leave mineral deposits on plumbing fixtures and equipment.

  • Example: A properly selected and maintained whole-building ion-exchange softener may protect matte-black or brushed-brass fixtures and tankless water heaters.


35
New cards

Site and basement drainage

  • Keep stormwater and sanitary wastewater systems separate where required.

  • Example: Do not connect foundation perimeter drains or interior floor drains to sanitary sewer lines unless the adopted code specifically permits the connection.