1/42
Looks like no tags are added yet.
Newer display technologies are desirable since they provide _________________________ with __________________________.
Higher frame rate, more lines per image
Bistable images are composed of ____________:___________________
2 shades, black and white
Gray scale displays present multiple ___________________________. These numerous levels allow the system to assign different gray shades to different _____________________ and to differentiate biological tissues of different _________________.
Levels of brightness, echo amplitudes, reflectivity
Two users controls on video monitors can alter characteristics of displayed image. What are they? What do each of them do? Bistable images are…
Contrast and Brightness
Contrast determines the range of brilliances in an image
Brightness: determines the brilliance of the image
Bistable images are only white and black and are high contrast
What first stores information and then later displays it? What is storage of the information in the thing called? Later, image data is ________ from the thing for display on the monitor.
Scan converters
Writing / Read
The scan converter changes the ___________________.
Monitors display video information as ______________________.
Format of data; horizontal lines
When can the data in the scan converter be altered?
In both the writing and reading process
Which type of number (analog or digital) are real work numbers that are found in everyday life and which are associated with computer devices?
Which has only discrete values and which have unlimited and continuous range of values?
Analog are real world and found in our everyday lives, unlimited/continuous range
Digital are associated with computer devices, discrete values
The ________________________, or image detail, of an analog scan converters use is ____________ because of the large number of storage elements within the matrix
Spatial resolution, excellent
What are the limitations of analog scan converters?
Image fade
Image flicker
Instability
Deterioration
Digital scan converters use computer technology to convert image into numbers, a process called… How is the image stored in the computer?
Digitizing; a series of 0’s and 1’s
What are the advantages of digital scan converters?
Uniformly: consistent quality
Stability: no fade or drift
Durability: not affected by age or heavy use
Speed: nearly instant processing
Accuracy: error free
What are two important elements of digital scan converters?
Pixel and bit
What is the smallest building block of a digital picture?
Pixel
What is pixel density? How is higher pixel density achieved? How is an image affected with high pixel density?
Number of picture elements per inch
Achieved with smaller pixels and more of them
It creates and image with higher detail and improved spatial resolution
What is the smallest amount of computer memory? What term is the word derived from? What is it classified as, what does this do for its value?
Bit, derived from the term binary digit
Classified as bistable, having a value of either 0 or 1
What is a binary number? Which type of number (analog or digital) is binary? What 2 choices are binary numbers based on?
A group of bits and is simply a series of zeros and ones
Digital numbers; 0 or 1
_________________, which are used in everyday life, are based on ten choices, 0-9
Decibel numbers
What is a group of 8 bits of computer memory called? What does a word of computer memory consist of?
Byte
2 bytes or 16 bits
Each pixel’s shade of gray is determined by the cluster of bits assigned to it.
With increasing numbers of bits per pixel, ___________________________________________, and have better __________________.
With fewer bits per pixel, _____________________________ and degrade ____________________.
More shades of gray appear on the image and better contrast resolution
Fewer shades of gray appear and degrade contrast resolution
To determine the number of gray shades that can be represented by a cluster of bits, _______________________________________.
Example: How many possible shades of gray are displayed with 5 bits of memory?
Multiply the number 2 by itself the same number of times as there are bits.
2Ă—2Ă—2Ă—2Ă—2 = 32 (the maximum of 32 different shades of gray can be within 5 bits)
Converting info from analog to digital form is advantageous because digital info is…
Far less susceptible to contamination
How many step process is it to translate image information from analog to digital and back again? What are the steps of the process?
5 step process
1.) Electrical signals created during reception are converted from analog to digital by the Analog-to-Digital converter (A-to-D)
2.) The digital info is stored in the scan converters computer memory.
- Any processing of the reflected signals before storage is called preprocessing
3.) The digital info still continues to be processed by the ultrasound systems computer
- Any processing after storage is the digital scan converter is called postprocessing
4.) Digital signal can’t be displayed on an analog display. The info must be translated back to analog form by a Digital-to-Analog converter (D-to-A)
5.) The analog signal is now displayed on the analog video display
What is preprocessing? Does the sonography control this? What does preprocessing do to the image?
What is postprocessing? Does the sonography control this? What does preprocessing do to the image?
Manipulation of image data before storage in the scan converter; sonographer controls this; alters the image forever and can’t be reversed
Manipulation of image data after storage in the scan converter; sonographer controls this; Since its after A-to-D conversion (digitization) and storage, all changes can be reversed (alterations to a frozen image must be postprocessing)

Study this!
What is defined as, he fundraiser can improve visualization of anatomic detail be enlarging a portion of an image to fill the entire screen?
What is this part of the image called?
What are the 2 different forms of magnification?
Magnification; region of interest
Read magnification and write magnification
When does read modification occur? How many steps does it consist of?
After the image data is stored in the scan converter
3 steps
1.) The ultrasound system scans the anatomy
2.) Image is converted from analog to digital and stored in the scan converter
3.) The sonographer identifies the ROI and the system reads and displays only the original data that pertains to the ROI
What is read modification characterized by?
The number of pixels per scan line in the magnified image is the same as the original image
Spatial resolution doesn’t change bc the number of pixels in the ROI is unchanged, however, the pixels are larger in the zoomed image
*Read magnification can be used on a frozen image and is postprocessing*
When is write magnification applied? How many steps does it consist of?
It is applied during data acquision, before storage in the scan converter
It has 4 steps…
1.) Ultrasound system scans the anatomy and create an image
2.) Image is converted from analog to digital and is stored in the scan converter
3.) Sonographer identifies the ROI. At that moment the scan converter discards all the existing data in the scan converter
4.) The ultrasound system scans, then recans only the ROI and writes new data into the scan converter
What is write magnification characterized by?
The image used to identify ROI is discarded and all new information is acquired
The number of pixels per scan lines in the ROI image is greater than that in the ROI’s portion of the original image
The increased number of pixels in the ROI improves spatial resolution; the pixels are the same size in both the old and zoomed image
*Write magnification cannot be used on a frozen image and thus, is preprocessing*
Codes excitation creates… What was coded excitation developed within the context of _______________. Where does coded excitation occur?
This speciality designed pulse distributes… What does this have to do with the FDA and what does it result it?
Very long sound pulses containing a wide range of frequencies
Bioeffects; it occurs in the pulser
Energy over a broad range of frequency range; the coded pulse is strong but still keeps the peak intensity below the FDA’s limit; improved penetration results
What is a method of using sonographic information from several different imaging angles to produce a single image?
The _______ frames in the compound acquisition sequence, the __________ the compound image quality. What does this reduces and minimize?
Spatial Compounding
More, better; reduces speckle and minimizes shadowing artifacts
What are 2 limitations of spatial compound imaging? What kind of steering is used with this technique and which type of transducers are avaliable?
- reduced frame rates
- reduced temporal resolution
It used electronic steering and is available with only phased array transducers
What is an advanced technique that reduces speckle artifact and noise in ultrasound images? What occurs with frequencies with this technique and images? What is reduced with this tequnique?
All reflected should pulses containing a large range of frequencies
Frequency compounding; the reflected signal is divided into sub-bands of limited frequencies, and an image is created from each sub-band - the images from the sub-band are then combined, or compounded, into a single image
Noise is reduced
What is an image processing method that makes pictures look sharper? How does this method work?
Edge enhancement
It increases the image contrast in the area immediately around the edge
What is an image processing technique that continues to display information from older images? What are some other names for this technique? How is an image under this technique displayed and what improvements are applied?
Temporal Compounding, AKA: persistence to temporal averaging
Displayed an image that contains history from earlier frames; creates a smoother image with reduced noise, higher signal-to-ratio, and improved image quality is produced
What is the main limitation of temporal compounding (persistence)? When is temporal compounding most effective?
Reduction is frame rates, which reduced temporal resolution
With slow moving structures
How do temporal compounding and spatial compounding differ?
Images used in temporal compounding are from the same view; images used in spatial compounding are from different views and angles
With sector-shaped images, the scan lines separate at increasing depths
Gaps, or missing data, exist between the scan lines, especially as the lines spread apart
What is a method of constructing new simulated data points to fill in the gaps? What does this technique increase and improve?
Interpolation
Increases line density and improves spatial resolution
What is a dynamic technique that produces images from sound reflections in an entirely new way?
Images are related to the _______________ properties of tissue.
What is the theory of elastography? Elastography has been applied to differentiate malignant from benign __________.
Elastography; mechanical
The theory is that tissues will deform differently following the application of force
Lesions
What describes the digital ultrasound laboratory in which images and additional medical information are digitized and stored on a large computer network? What are the 3 main advantages?
PACS (Picture Archiving and Communications System)
1.) Virtually instant access to achieved studies
2.) No degradation of data
3.) Has the ability to transmit images and reports to remote sites
How are information and images stored in a PACS? What is the primary digital storage devices used in PACS?
In the archival system; computer hard drives
What is a set of rules, or protocols, that allows imaging systems to share information on a network? What does this do?
DICOM (Digital imaging and Computers in Medicine)’
DICOM assures that current imaging modalities can communicate and guarantees all devices in the future will easily attach to the PACS network