Why is sulfite mainly considered a lower-pressure boiler treatment?

It adds dissolved solids and can decompose at higher pressure

2
New cards

AWT Chapter 3 general sulfite pressure limit?

Under about 900 psig

3
New cards

Chapter 3 sulfite residual guideline up to 600 psig?

About 5-50 mg/L

4
New cards

Chapter 3 sulfite residual guideline above 600 psig?

About 5-20 mg/L

5
New cards

At what temperature/pressure can sulfite react with iron oxide?

Above about 430°F / 350 psia

6
New cards

What protective oxide can result from sulfite/iron-oxide reaction?

Magnetite, Fe3O4

7
New cards

Is sulfite considered a strong passivating agent in LP boilers?

No

8
New cards

Why avoid large sulfite overfeeds?

Added TDS and high-pressure decomposition concerns

9
New cards

Advanced boiler training: sulfite residual at 0-150 psi?

30-60 ppm

10
New cards

Advanced boiler training: sulfite residual at 150-300 psi?

20-40 ppm

11
New cards

Advanced boiler training: sulfite residual at 300-600 psi?

20-30 ppm

12
New cards

Advanced boiler training: sulfite residual at 600-900 psi?

10-15 ppm

13
New cards

Advanced boiler training: sulfite residual at 900-1200 psi?

5-10 ppm

14
New cards

Advanced training: sulfite recommendation at 1500 psi?

Not recommended

15
New cards

What happens to acceptable water quality as boiler pressure rises?

Required purity generally becomes more stringent

16
New cards

How often should low-pressure boilers generally be monitored?

Daily

17
New cards

How often should higher-pressure boilers generally be monitored?

About once per shift

18
New cards

How are many high-pressure field-erected boilers monitored?

Continuous online monitoring for many parameters

19
New cards

What pressure does psig reference?

Pressure above atmospheric pressure

20
New cards

What pressure does psia reference?

Absolute pressure from a vacuum

21
New cards

How do you convert psig to psia?

Add about 14.7 psi

22
New cards

How do you convert psia to psig?

Subtract about 14.7 psi

23
New cards

As boiler pressure increases, what happens to required feedwater purity?

It increases

24
New cards

Why does boiler-water treatment become more restrictive as pressure rises?

Higher pressure reduces tolerance for contaminants and dissolved solids

25
New cards

Which boiler class is below about 300 psig?

Low pressure

26
New cards

Which boiler class is about 300-900 psig?

Medium pressure

27
New cards

Which boiler class is about 900-1,200 psig?

High pressure

28
New cards

Which boiler class is above about 1,200 psig?

Very high pressure

29
New cards

In what pressure range is sulfite generally used?

Below about 900 psig

30
New cards

Why does sulfite become less desirable at higher boiler pressure?

It adds dissolved solids and can decompose at elevated pressure/temperature

31
New cards

As boiler pressure increases, what generally happens to allowable sulfite residual?

It decreases

32
New cards

Which can tolerate more conventional internal treatment: LP or HP boilers?

Low-pressure boilers

33
New cards

Which requires greater feedwater purity: LP or HP boilers?

High-pressure boilers

34
New cards

What is the overall pressure-treatment relationship?

Higher pressure = higher purity and tighter chemistry control