Structural Biology and Protein Engineering: Mass Spectrometry and Proteomics

0.0(0)
Studied by 0 people
call kaiCall Kai
learnLearn
examPractice Test
spaced repetitionSpaced Repetition
heart puzzleMatch
flashcardsFlashcards
GameKnowt Play
Card Sorting

1/33

flashcard set

Earn XP

Description and Tags

Vocabulary practice flashcards covering protein chemistry, mass spectrometry principles, instrumentation, fragmentation nomenclature, and quantitative proteomics methods from the lecture notes.

34 Terms

1
New cards

Zwitterion

A dipolar molecule containing both positive and negative functional groups simultaneously, resulting in a net overall electrical charge of zero, as observed for free standard amino acids at physiological pH (≈7.4\approx 7.4).

2
New cards

Histidine (pKa≈6.0pK_a \approx 6.0)

A basic amino acid whose imidazole side chain has a pKapK_a close to physiological pH (≈7.4\approx 7.4), allowing it to readily equilibrate between protonated and deprotonated states and participate in catalytic proton transfer in enzyme active sites.

3
New cards

Mass-to-charge ratio (m/zm/z)

The fundamental physical property measured by a mass spectrometer, representing the mass of a given ion (mm, in Daltons) divided by its elementary charge number (zz).

4
New cards
<p>Mass Spectrometer Architecture</p>

Mass Spectrometer Architecture

The three core functional compartments of a mass spectrometer maintained under high vacuum: the ion source (ionizzazione), the mass analyzer (separazione ioni), and the ion detector (rivelazione ioni), connected to sample introduction and computer processing systems.

5
New cards

Base peak

The most intense peak within a recorded mass spectrum, assigned an arbitrary relative abundance of 100%100\%, against which all other molecular and fragment ion intensities are normalized.

6
New cards

Electron Ionization (EI)

A classical 'hard' gas-phase ionization technique in which volatile molecules are bombarded with a 70 eV70\,eV electron beam, causing extensive covalent bond fragmentation useful for structural determination and spectral library matching.

7
New cards

Chemical Ionization (CI)

A 'soft' gas-phase ionization method in which analyte molecules interact with collision-generated reagent gas ions (e.g., CH4CH_4, NH3NH_3, or isobutane), producing protonated molecular species ([M+H]+[M+H]^+) with reduced fragmentation.

8
New cards

Fast Atom Bombardment (FAB)

A liquid-phase matrix ionization method where non-volatile analytes dissolved in a viscous matrix (such as glycerol, thioglycerol, or DEA) are bombarded under vacuum with a beam of high-energy neutral atoms to produce intact gaseous ions.

9
New cards
<p>Coulombic Explosion (Droplet Fission)</p>

Coulombic Explosion (Droplet Fission)

The disintegration event in Electrospray Ionization where solvent evaporation shrinks charged droplets beyond the Rayleigh stability limit, causing repulsive electrostatic forces to overcome surface tension and release gas-phase ions.

10
New cards

Electrospray Ionization (ESI)

An atmospheric pressure, 'soft' ionization technique where a high potential difference (±5 kV\pm 5\,kV) applied across an effluent capillary nebulizes liquid samples, producing multiply charged ions ([M+nH]n+[M+nH]^{n+}) and extending mass range analysis to large biomacromolecules.

11
New cards

Deconvolution

A computational algorithm that determines the true, uncharged molecular mass (MM) of a macromolecule by analyzing consecutive pairs of multiply charged ESI spectral peaks (m1,m2m_1, m_2) differing by a single proton charge.

12
New cards

Matrix-Assisted Laser Desorption/Ionization (MALDI)

A 'soft' solid-phase ionization method wherein an analyte co-crystallized with an excess of UV-absorbing weak organic acid is desorbed by high-intensity pulsed laser bursts (106−1010 W/cm210^6 - 10^{10}\,W/cm^2), generating predominantly singly charged ([M+H]+[M+H]^+) biopolymer ions.

13
New cards

Quadrupole Mass Analyzer (Q)

A continuous mass filter made of four parallel hyperbolic metal rods; applying combined direct current (DC) and radiofrequency (RF) potentials allows only ions of a chosen m/zm/z to maintain a stable oscillatory path to the detector.

14
New cards

Ion Trap Mass Analyzer (IT)

A dynamic analyzer that confines ions in a three-dimensional or two-dimensional radiofrequency quadrupole field alongside a helium or argon buffer gas, expelling ions sequentially in time according to their m/zm/z to achieve tandem MSnMS^n fragmentation.

15
New cards

Fourier Transform Ion Cyclotron Resonance (FT-ICR)

An ultra-high-resolution analyzer where ions trapped in a cubic cell within a strong uniform magnetic field orbit at an m/zm/z-dependent cyclotron frequency; image currents detected on receiver plates are decoded into a mass spectrum via Fourier transformation.

16
New cards
<p>Orbitrap Mass Analyzer</p>

Orbitrap Mass Analyzer

An electrostatic trap consisting of a central spindle electrode and an outer barrel-like electrode; trapped ions oscillate harmonically along the axial coordinate with a frequency ω=km/z\omega = \sqrt{\frac{k}{m/z}}, providing high resolution (R≤100,000R \le 100{,}000) without magnetic fields.

17
New cards

Time-of-Flight (TOF) Analyzer

A non-scanning mass analyzer that accelerates ion packets to identical kinetic energy (Ec=12mv2E_c = \frac{1}{2}mv^2) through an evacuated drift tube, separating them based on their velocities and transit arrival times at the detector.

18
New cards
<p>Reflectron (Electrostatic Reflector)</p>

Reflectron (Electrostatic Reflector)

An electrostatic ion mirror located in a TOF analyzer that repels ions into a second flight tube; ions with higher initial kinetic energy penetrate deeper into the retarding field, exiting late enough to arrive at the detector simultaneously with slower ions of identical m/zm/z.

19
New cards

Delayed Extraction (DE)

A performance-enhancing technique in MALDI-TOF where extraction voltage is applied a brief moment after the laser pulse, correcting for the initial velocity distribution of ions desorbed from the matrix surface.

20
New cards

Mass Resolution (RR)

The quantitative capability of a mass spectrometer to separate two closely spaced peaks, calculated via the Full Width at Half Maximum (FWHM) approach as R=mΔmR = \frac{m}{\Delta m}, where Δm\Delta m is the peak width at half its maximum height.

21
New cards

Collision-Induced Dissociation (CID)

A tandem mass spectrometry activation process where precursor ions accelerated into an intermediate collision cell collide with inert gas atoms (N2N_2, ArAr), converting kinetic energy into internal vibrational energy that breaks covalent peptide bonds.

22
New cards
<p>Peptide Backbone Cleavage Nomenclature</p>

Peptide Backbone Cleavage Nomenclature

The standard Roepstorff-Fohlman and Biemann nomenclature defining peptide backbone fragmentation: ai,bi,cia_i, b_i, c_i ions retain the N-terminal fragment, whereas xi,yi,zix_i, y_i, z_i ions retain the C-terminal fragment, cleaved respectively at Cα−CC_\alpha-C, amide, and N−CαN-C_\alpha bonds.

23
New cards

Electron Transfer Dissociation (ETD)

A non-ergodic MS/MS fragmentation method where multiply-charged peptide cations capture low-energy electrons from reagent radical anions, preferentially cleaving the N−CαN-C_\alpha bond to form cc- and zz-type ions while preserving labile post-translational modifications.

24
New cards

Two-Dimensional Gel Electrophoresis (2DE)

An orthogonal protein separation method created by O'Farrell (1975) that resolves complex cellular proteomes first by isoelectric point (pI) using isoelectric focusing (IEF) on IPG strips, followed by SDS-PAGE in the second dimension based on molecular weight.

25
New cards
<p>Blue Native PAGE (BN-PAGE)</p>

Blue Native PAGE (BN-PAGE)

A non-denaturing electrophoretic technique utilizing Serva Blue G dye to impart an artificial negative charge on intact protein complexes without disrupting quaternary assemblies, allowing the isolation of native membrane complexes and multiprotein machinery.

26
New cards

Difference Gel Electrophoresis (DIGE)

An advanced gel-based differential proteomic technique where control, treated, and internal standard samples are minimally pre-labeled on 1−2%1-2\% of lysine residues using matched fluorescent cyanine dyes (Cy3, Cy5, Cy2) and co-resolved in a single 2D gel.

27
New cards

SILAC (Stable Isotope Labeling by Amino acids in Cell culture)

An in vivo metabolic labeling strategy where experimental cell populations are grown in media containing either light or stable heavy-isotope-labeled essential amino acids (13C^{13}C/15N^{15}N Lys or Arg), enabling relative quantitation via MS1 peak pair ratios (H/LH/L).

28
New cards

Isotope-Coded Affinity Tag (ICAT)

A cysteine-directed chemical labeling reagent featuring an iodoacetamide reactive group, a light or deuterated (+8 Da+8\,Da) linker, and a biotin affinity tag designed for avidin-based purification prior to LC-MS/MS analysis.

29
New cards
<p>iTRAQ (Isobaric Tags for Relative and Absolute Quantitation)</p>

iTRAQ (Isobaric Tags for Relative and Absolute Quantitation)

A multiplex chemical tagging method that labels primary amines of digested peptides with isobaric reagents; upon tandem MS/MS collision, the tags cleave to liberate low-mass reporter ions (m/z=114−117m/z = 114 - 117 or up to 8-plex) for simultaneous relative quantitation.

30
New cards

Spectral Counting

A label-free quantitative proteomics metric that correlates the total number of identified MS/MS fragmentation spectra assigned to a given protein across LC-MS/MS runs with its relative abundance in the biological sample.

31
New cards
<p>MALDI-TOF Microbial Identification Score</p>

MALDI-TOF Microbial Identification Score

A numerical similarity index generated by comparing an unknown microorganism's mass spectrum (m/z=2,000−15,000 Dam/z = 2{,}000 - 15{,}000\,Da, mainly ribosomal proteins) against reference libraries: scores ≥2.000\ge 2.000 guarantee secure species identification, whereas scores below 1.7001.700 denote unreliable matches.

32
New cards

MALDI Imaging Mass Spectrometry (MALDI-IMS)

A spatially resolved mass spectrometry technique that records the spatial distribution and relative abundances of peptides, proteins, or small metabolites directly across histological tissue sections without prior macroscopic extraction.

33
New cards

Biotin-Switch Method

A multi-step biochemical workflow for mapping S-nitrosylation wherein unmodified free cysteines are blocked with MMTS, S-nitrosylated thiols are selectively reduced with ascorbate, and newly freed thiols are conjugated to biotin-maleimide for affinity capture.

34
New cards

Phosphorylation Neutral Loss

A diagnostic fragmentation event during tandem MS/MS collision of phosphopeptides, characterized by the preferential neutral elimination of a 98 Da98\,Da phosphoric acid (H3PO4H_3PO_4) moiety from modified serine or threonine residues.