ch. 7 X-Ray Interactions with Matter

0.0(0)
Studied by 0 people
call kaiCall Kai
learnLearn
examPractice Test
spaced repetitionSpaced Repetition
heart puzzleMatch
flashcardsFlashcards
GameKnowt Play
Card Sorting

1/58

encourage image

There's no tags or description

Looks like no tags are added yet.

59 Terms

1
New cards

positron

a positively charged electron

2
New cards

b

Pair production:
a) seldom occurs during radiographic procedures
b) never occurs during radiographic procedures
c) it depends on the procedure
d) occurs very often during radiographic procedures

3
New cards

radiolucent

air is considered:

4
New cards

c

The Compton electron

A) typically exits the patient as part of the remnant radiation
B) does not have enough energy to produce further interactions
C) has enough energy to produce further interactions
D) A and B

5
New cards

b

The x-ray photon produced during classical scattering:
a) is lower energy than the incident photon
b) is the same energy as the incident photon
c) continues traveling in the same direction as the incident photon
d) is higher energy than the incident photon

6
New cards

t

The higher the atomic number of an atom, the greater the probability of a photoelectric interaction T/F

7
New cards

a light shade of gray

Radiation interacting with bone is more likely to be absorbed, resulting in that area of the image being:

8
New cards

c

Compton scattering typically occurs with:
a) low-energy photons
b) high-energy photons
c) moderate-energy photons
d) all of the above

9
New cards

d

Compton scattering involves the x-ray photon:
a) passing through the atom without any change
b) being absorbed in the atom
c) removing an inner-shell electron
d) removing a middle- or outer-shell electron

10
New cards

bone

Photoelectric interactions are more likely to occur in:

11
New cards

d

If a middle-shell electron is removed during a Compton interaction:
a) secondary photons are produced
b) a secondary electron is ejected
c) a Compton scatter photon is produced
d) all of the above

12
New cards

c

Reducing the amount of Compton scattering:
a) is impossible
b) is extremely difficult to accomplish
c) is very important in producing quality images
d) all of the above

13
New cards

d

Classical interactions are also known as:
a) coherent scattering
b) Compton scattering
c) Thomson scattering
d) A and C

14
New cards

d

Following absorption of the incident photon in the atom's nucleus, a photodisintegration interaction may result in:
a) positrons being ejected from the nucleus
b) neutrons being ejected from the nucleus
c) protons being ejected from the nucleus
d) B and C

15
New cards

has a high atomic number

Barium is used as a contrast agent to visualize soft tissue structures such as the stomach because it:

16
New cards

classical scattering, Compton scattering, photoelectric effect, pair production, and photodisintegration. The first three occur within the range of energy used in diagnostic radiography.

X-rays may interact with matter in five ways, depending on their energy:

17
New cards

rather low energy (generally less than 10 keV).

In classical interaction, the incident x-ray photon is:

18
New cards

classical

Which scattering don't Rad-Techs worry about?

19
New cards

absorbed in the body through other interactions and do not contribute significantly to the image, but add slightly to patient dose

Because of its low energy, most classical scatter photons are

20
New cards

20-40 keV

Compton scattering energy range:

21
New cards

3 things compton scattering does

◦It ionizes the atom, making it unstable.

◦The ejected electron, called a Compton electron or secondary electron, leaves the atom with enough energy to go through interactions of its own in adjacent atoms.

◦The incident photon is deflected in a new direction and is now a Compton scatter photon with enough energy to go through other interactions in the tissues or exit the patient and interact with the image receptor.

22
New cards

The problem with Compton scatter interacting with the image receptor:

it is not following its original path through the body and strikes the image receptor in the wrong place, resulting in image fog

23
New cards

compton scattering

one of the most prevalent interactions btwn photons and human body in general diagnostic imaging

24
New cards

increases; however, with this increase in photon energy, the likelihood of Compton interactions relative to photoelectric interactions also increases

Compton scattering: As x-ray photon energy increases, the probability of that photon penetrating a given tissue without interaction

25
New cards

2/3

Compton scatter photons retain approximately how much of the their energy?

26
New cards

compton

What kind of scattering is the major source of occupational exposure?

27
New cards

20-120 kVp

Photoelectric interactions occur throughout which energy range?

28
New cards

inner shell orbital electrons of tissue atoms

Which electrons are affected by photoelectric interactions?

29
New cards

all of it

How much of a photoelectric incident x-ray photon is absorbed?

30
New cards

Photoelectric event

What kind of incident x-ray creates images?

31
New cards

photoelectron

name of ejected electron in photoelectric event:

32
New cards

the incident photon energy minus the binding energy of the orbital electron.

The energy transfer between the incident photon and inner-shell electron is equal to

33
New cards

significantly

How does photoelectric absorption by the patient contribute to dose accrued?

34
New cards

the incident x-ray photon energy must be greater than or equal to the inner-shell binding energy of the tissue atoms involved

What must happen for photoelectric interactions to occur?

35
New cards

1.02 MeV or greater

At what energy does pair production occur?

36
New cards

nucleus of tissue atom

What part of the atom does a pair production incident x-ray interact with?

37
New cards

positron (positively charged electron) and an electron.

What particles are produced in pair production?

38
New cards

.51 MeV

energy equivalent of particles to exist in pair production?

39
New cards

What event occurs with a positron?

In this annihilation event, the positron and the electron it interacts with are destroyed and their energy is converted into two x-ray photons that radiate out of the atom.

40
New cards

X-ray photon energy increases

Likelihood of Compton interaction increases as

41
New cards

In any direction

Compton scatter photons may travel

42
New cards

equal, low

In soft-tissue atom, energy of photoelectron is to incident electron because low binding energy. In bone, energy is because atoms is greater

43
New cards

Absorption and transmission

Photoelectric contributes to patient dose and balance image by

44
New cards

Compton and photoelectric interactions. Both observed with cascading effect and secondary photons effect

Interactions involved in tissue ionization

45
New cards

total absorption of incident photons. Characteristic cascade produces secondary photons and is ejected out the atom with enough energy to undergo many more interactions

Photoelectric event results

46
New cards

The energy of incident photons and the atomic number of the tissue atoms

Photoelectric depends on

47
New cards

Incident x-ray photon energy is equal to or slightly greater than the inner-shell binding energy of the tissue atom

The greatest number of photoelectric occurs when

48
New cards

As incident photon energy increases.

…Photoelectric declines and increases the chance on penetration of tissue. This function is a cubic relationship, the probability of a photoelectric event is inversely proportional to the third power of x-ray energy. This means if kVp is high then less absorption takes place and absorption is necessary for image formation

49
New cards

pair production

Occurs with very high energy photon of 1.02 MeV or greater. Incident electrons has enough electron to enter the nucleus of tissue atoms

50
New cards

dangers of positron

Travels until it strikes an electron, causing an annihilation event. Electrons and positrons are destroyed and their energy is converted into 2 x-ray photons that radiates out of the atom

51
New cards

Diagnostic range we use is 30-150 kVp

Pair production and photodisintegration does not occur in radiography because

52
New cards

Photodisintegration

Occurs at energy more than 10 MeV striking the nucleus and making it unstable. The nucleus of atom involved regains stability by ejecting a nuclear particle such as a proton, neutron or alpha particle

53
New cards

Differential absorption

The difference between the x-ray photons absorbed photoelectrically versus those that penetrate the body. So called because different body structures absorbs at different extent

54
New cards

Differential absorption

Primary beam that creates an image is called?

55
New cards

transmission

Refers to those x-ray photons to pass through the body and reach the image receptor. Some x-rays has to pass through the body to produce image.

56
New cards

Transmission, scatter and remnant (exiting photons)

Interaction that occurs at the IR

57
New cards

kVp, mAs, SID

What items are included when one is listing a "technique"?

58
New cards

incident happens outside the tube, whereas filament occur inside the tube

The difference between incident and filament electrons?

59
New cards

Thompson excites 1 electron, whereas rayleighs excites the whole atom

Difference between thompson and rayliegh