Locations to measure body temperature
Oral (O), Rectal ®, Axillary (Artmpit), tympanic/aural (ear), temporal artery (forehead)
Oral temperature
Under tongue-If they drank something hot/smoked wait 15 minDon't use oral for people with seizures, nose/mouth surgery, suicidal, young children
Rectal Temp.
Super accurateUsed for unconscious patients or after mouth surgery
Axilary
Least accurat Use frequently for newborns
Tympanic
great for core body temperature, Used by many pediatric and ICU
Temporal Artery
Quickest and least invasive, More accurate than tympanic but less than recturm
Glass thermometers have a scale of
93 to196 F
Pulse
every heartbeat produces a wave of blood
Pulse places
carotid, radial, mandibular, temporal, femoral
Pulse rate
how often a person's heart beats/min
Normal pulse rate
60to80 BPM
Who has higher pulse men or women
women
Newborn pulse rate
120to140 BPM
Pulse rate increases in proportion to body temp.
pulse increases 10 beats for every 1 degree F increase
Tachycardia
pulse rate consistently above normal (100 beats per minute), may signify hemorrhage, heart disease, heart failure
Bradycardia
pulse rate consistently slower than normal (55-60), common in athletes, can be signal of cerebral hemorrhage or heart block
Pulse volume
hemorrhage pulse is weak
PV full/bounding
pulse is strong and difficult to obliterate
Dysrhythmia
Pulse irregular in force and rhythm, sign of some form of heart disease/overcative thyroid gland
Auscultation
listening to sounds and counting apical pulse normally herd at heart's apex, point of maximal impulse
Doppler device
used to detect peripheral pulses, apply gel on skin and put doppler over artery being assessed
Radial pulse
radia artery in wrist most commonly used
Apical pulse
more accurate than radial and is always used for kids under 2
Apicalradius pulse
Of suspected patients heart is pumping properly
Pedal pulse
Foot pulse is over tibial artery indicated unrestricted blood flow to lower extremities (check in both feet), if not possible must write "pedal pulse not palpable"
Popliteal pulse
posterior to knee used to assess circulation to lower leg
Carotid pulse
neck pulse edge of stercocleidomastoid muscle
Apnea
cessation of breathing that occurs in sudden infant death (SIDS< sleep ones and other conditions
Average breathing rate
12/18 breaths amin and for nw borns ~40 breaths
Eupnea
normal breathing rate
Tachypnea
abnormally repaid 20/24
Bradypnea
abnormally slow breathing below 10
Cheyenna
Stokes respiration - alternating deep rapid breathing followed by periods of apnea
Biot's respiration
varying depth and rate of respiration followed by apnea associated with meningitis or brain damage
Kussmaul's respirations
accumulation of poisons in uremia and diabetic coma increase dearth of respirations, increase acid in body and body tried to compensate by removing excess acid through fast breathing
Stertorous breathing
air passes through secretions in air passage, bubbling noise before death; when air passage fills with mucus
Dyspnea
difficult/painful breathing
Orthopnea
can only breathe upright
Asthma
difficulty breathing due to bronchial spams and edema
Cheyenna
stokes respirations - slow and shallow at first but gradually get faster, tapering opp until they stop. Last few seconds and repeats.
How many times a day is BP measured
at least 2
What is blood pressure determined by
cardiac output and peripheral resistance (resistance of biodisses to flow)
Arterioscelerosis
harding of blood vessels
Atherosclerosis
build up of plaque in blood vesses
Hypertension
high BP (circulatory problem)
Hypotension
low Bp (hemorrhage of shock)
Mean arterial pressure (MAP)
mathematic approximation of diastolic pressure plus ⅓ of pulse pressure
Diastolic is ⅓ to ½ of systolic pressure
Average BP
120/80
Direct and indirect measurement of Bp
direct inserting a probe/acter into patient heart and indirect BP cuff
Syphometer
placed over branchial rather
Aneroid manometer
one we have with the handheld pump and clock
Korotstoff
Orthostatic/postural hypotension
severe drop in BP
Oximetry
noninvasive procedure using photoelectric impulses to measure amount of light transmitted/reflected by deoxygenated compared to oxygenated hemoglobin