The visibility and the accuracy of the anatomic structures
Sharpness
Spatial resolution
Distortion
Visibility
Brightness
Contrast
Brightness
The visibility factor of image quality
The amount of luminance
Monitor Quality
With digital imaging, how will brightness appear if the image was slightly over-exposed
The image will have appropriate brightness after processing
Why is EI important
True representation of the receptor exposure
Quantum noise is a result of
Too few x-ray photons reaching the IR
Quantum noise is also known as
Quantum Mottle
Quantum mottle appears as a
Blotchy or grainy appearance
What is the best method for reducing quantum mottle on a radiographic image?
Increasing the mAs of an x-ray beam
Noise is another word for
Quantum noise
Saturation is
Over exposure
Oversaturation is
8-10 times the exposure needed
What type of relationship exists between mAs and receptor exposure
Directly proportional
What formula is used to calculate mAs
mA X s = mAs
Convert milliseconds to seconds
move the decimal point 3 to the left
mAs can be doubled or halved by
Doubling or halving mA or time
Maintain mAs
Double mA and Halving time
Halve mA and Double time
Reciprocity Law
We can change the mA and change the exposure time by the same amount and still have the same mAs
Rule of thumb for mAs
Double or halving doubles or halves receptor exposure
Any kVp change is in
15% percent intervals
a 15% increase in kVp effect on receptor exposure
doubles
If you wanted to maintain receptor exposure and you increase kVp by 15%, how would the mAs need to be adjusted?
Halve mAs
IF you use 6 mAs with 50kVp and then change to 50 kVp what mAs will you need to maintain the original exposure
3
Generator output & technique/ receptor exposure
Decrease mAs by half
Increasing generator
decrease mAs by half
focal spot and receptor exposuer
Anodes with larger angles will
contribute to anode heel effect
decrease collimation and larger SIS
larger anode heel effect
What SID would produce the highest receptor exposure
40
Double SID
¼ of receptor exposure
Direct exposure formula
Exposure maintenance formula
Exposure maintenance formula
mAs1/ mAs2= (SID1)2/(SID2)2
Which of the following would result in the least amount of receptor exposure
4in OID
Which of the following filtration amounts would result in the least receptor exposure
3mm AL
Which of the following field sizes would result in the least receptor exposure
8×10
Beam Restriction Technique Adjustment
-Large anatomic structure/ body parts
-High kVp
-Low efficency/ no grid
Increased patient thickness will cause receptor exposure to
decrease
Which of the following field sizes would result in the most receptor exposure
14 × 17
Which will result in the least amount of receptor exposure
16 cm patient thickness
Using barium would result in
Decreased receptor exposure
Emphysema would result in
Increased receptor exposure
Casting material would result in
Decreased receptor exposure due to increased thickness
Grids remove
Scatter, and low energy photons
When we add a grid we need to
Increase our mAs
Going from CR (Computed Radiography) to DR (Digital Radiography)
Half the mAs
Image contrast is the
difference between adjacent IR exposure levels.
Subtle differences between the shades of grey next to eachother
Low contrast
Less discernable shades of grey
High contrast
Range/ scale of the shades or colors that we see on an image
Grayscale
High contrast has a
Short grey scale
Long grayscale has a
Low contrast
Radiographic/ image contrast
Allows visibility of anatomic structures
A radiograph that has brightness levels very similar to each other
Has low contrast and has a long grayscale
The proper ____ is important for the desired ____ through the patient for a given examination. This causes signal differences to the digital detector
kVp, Differential attenuation
Subject contrast is the
range of differences in the intensity of the x-ray beam after it has been attenuated by the subject.
Subject contrast is effected by
kVp, The amount, and type of irradiated material
Subject contrast is the
Remnant beam intensity
When there are significant tissue variations
There will be high subject contrast
the greater difference between the absorption of the tissue
The greater the contrast
A abdomen with similar tissue makes up will have
Low subject contrast
Barium in an abdomen x-ray will ____ subject contrast
Increase
Increased patient thickness will
Decrease subject contrast, and less differential absorption
Different ____ Will also effect subject contrast
pathologies
A high contrast image is with a _____ kVp
Low
A low contrast image is taken with a _____ kVp
High
High contrast images have
Less transmission and more differential absorption
Low contrast images have
More transmission and less differential absorption
What does an increased kVp have on scatter production
Increased kVp results in more scatter