1/83
Looks like no tags are added yet.
What term describes the dark or black portion of a dental image?
Radiolucent
What term describes the light or white portion of a dental image?
Radiopaque
Give an example of a structure that appears radiolucent.
Air space
Give three examples of structures that appear radiopaque.
Enamel, dentin, and bone
What are the two visual characteristics of a dental image?
Density and contrast
What are the three geometric characteristics of a dental image?
Sharpness, magnification, and distortion
Define density.
The overall blackness or darkness of a dental image
Which three exposure factors control density?
Kilovoltage (kV), milliamperage (mA), and exposure time
What happens to density when mA is increased?
Density increases and the image appears darker
What happens to density when exposure time is increased?
More x-rays reach the receptor, so density increases and the image appears darker
How does increased subject thickness affect density?
Fewer x-rays reach the receptor, so density decreases and the image appears lighter
How can the radiographer compensate for a large patient?
Increase the kV, mA, or exposure time
Define contrast.
The difference in degrees of blackness (densities) between adjacent areas on a dental image
Which one exposure factor directly controls contrast?
Kilovoltage (kV)
What happens to contrast when kV is increased?
Contrast decreases (low contrast, long-scale contrast)
What happens to contrast when kV is decreased?
Contrast increases (high contrast, short-scale contrast)
What does a short-scale contrast image look like?
Few densities, mostly areas of black and white (high contrast)
What does a long-scale contrast image look like?
Many densities, many shades of gray (low contrast)
Which contrast scale may help caries stand out?
Short-scale contrast (lower kV), because it shows more black and white areas
Which contrast scale helps show subtle bone changes in periodontal disease?
Long-scale contrast (higher kV), because it shows many shades of gray
What two factors determine the overall contrast of a dental image?
Film contrast and subject contrast
What is a stepwedge and what is it made of?
A device of uniform-layered thicknesses of x-ray-absorbing material, usually aluminum, in 2-mm steps
What is a stepwedge used for?
Demonstrating short-scale and long-scale contrast and monitoring film, film processing, digital sensors, and x-ray machine calibration
Define sharpness.
The capability of the receptor to reproduce the distinct outlines of an object (also called detail, resolution, or definition)
What is penumbra?
The fuzzy, unclear area surrounding a structure on an image; the unsharpness or blurring of the edges
What three factors influence sharpness?
Focal spot size, film composition, and movement
How does focal spot size affect sharpness?
The smaller the focal spot, the sharper the image
How does film crystal size affect sharpness?
Larger crystals (faster film) produce less sharpness; smaller crystals (slower film) produce more sharpness
How does movement affect sharpness?
Movement of the tubehead, receptor, or patient during exposure decreases sharpness
What causes image magnification?
The diverging paths of the x-ray beam as it radiates from the focal spot
What two factors influence magnification?
Target-receptor distance and object-receptor distance
How does a longer PID affect magnification?
A longer PID (greater target-receptor distance) decreases magnification
How does object-receptor distance affect magnification?
The closer the tooth is to the receptor, the less magnification; increased distance increases magnification
How can magnification be limited?
Use the longest target-receptor distance and the shortest object-receptor distance
Define dimensional distortion.
A variation in the true size and shape of the object being radiographed, caused by unequal magnification of different parts of the same object
What two factors influence distortion?
Object-receptor alignment and x-ray beam angulation
How is distortion minimized?
Position the object and receptor parallel to each other and direct the beam perpendicular to both
Why is the bisecting technique used for periapical images?
It is an alternative to the paralleling technique, which is the preferred method
Name four situations in which the bisecting technique may be used.
Shallow palate, pain when closing on a bite-block, rubber dam in place, or paralleling instruments not available
State the rule of isometry.
Two triangles are equal if they have two equal angles and share a common side
Where is the receptor placed in the bisecting technique?
Along the lingual surface of the tooth
What is the imaginary bisector?
A plane that divides in half the angle formed by the receptor and the long axis of the tooth
How is the central ray directed in the bisecting technique?
Perpendicular (90 degrees) to the imaginary bisector
What do the two imaginary triangles in the bisecting technique represent?
Congruent right triangles; the long axis of the tooth and the plane of the receptor are the hypotenuses
What does the sun-and-tree shadow analogy illustrate?
The shadow equals the tree's height when the rays are perpendicular to the plane bisecting the angle; flat rays give a longer shadow and steep rays a shorter one
Define horizontal angulation.
The positioning of the PID and central ray in a side-to-side plane
What is correct horizontal angulation?
The central ray is directed perpendicular to the curvature of the arch and through the contact areas, so contacts appear open
What results from incorrect horizontal angulation?
Overlapped contacts, making the image nondiagnostic for interproximal areas
Define vertical angulation.
The positioning of the PID in an up-and-down plane, measured in degrees on the tubehead
What causes foreshortening?
Excessive (too steep) vertical angulation, or directing the central ray perpendicular to the receptor instead of the imaginary bisector
How is foreshortening corrected?
Decrease the vertical angulation
What causes elongation?
Insufficient (too flat) vertical angulation, or directing the central ray perpendicular to the long axis of the tooth instead of the imaginary bisector
How is elongation corrected?
Increase the vertical angulation
What is the vertical angulation range for maxillary canines?
+45 to +55 degrees
What is the vertical angulation range for maxillary incisors?
+40 to +50 degrees
What is the vertical angulation range for maxillary premolars?
+30 to +40 degrees
What is the vertical angulation range for maxillary molars?
+20 to +30 degrees
What is the vertical angulation range for mandibular canines?
-20 to -30 degrees
What is the vertical angulation range for mandibular incisors?
-15 to -25 degrees
What is the vertical angulation range for mandibular premolars?
-10 to -15 degrees
What is the vertical angulation range for mandibular molars?
-5 to 0 degrees
List the five basic rules of the bisecting technique.
Receptor placement covers the area; receptor against lingual surface with 1/8 inch beyond edge; central ray perpendicular to imaginary bisector; central ray through the contacts; beam centered on the receptor
How far must the receptor extend beyond the incisal or occlusal surfaces?
Approximately one eighth of an inch
What results from failing to center the x-ray beam on the receptor?
A partial image, or cone-cut
What receptor size and orientation are used with the bisecting technique?
Size 2; vertical for anterior teeth and horizontal for posterior teeth
What is the Rinn BAI system?
A bisecting angle instrument with plastic bite-blocks, plastic aiming rings, and metal indicator arms that aids angulation and helps prevent cone-cuts
Why add a rectangular collimator to the Rinn BAI?
To significantly reduce the patient's radiation exposure
Which receptor holders have no aiming ring, requiring the operator to determine angulations?
The Stabe Bite-block and the Rinn Snap-A-Ray Holder
Which PID length is typically preferred with the bisecting technique?
The short (8-inch) PID
How should the patient's head be positioned for bisecting exposures?
Upright, with the arch being imaged parallel to the floor and the midsagittal plane perpendicular to the floor
When using film, which way does the white side face and where is the identification dot placed?
The white side faces the teeth, and the dot is placed at the incisal or occlusal edge
Why are anterior teeth exposed first?
Anterior placements are more tolerable and less likely to cause gagging
What is the maxillary anterior exposure sequence?
Right canine (#6), incisors, then left canine (#11), moving from patient's right to left
What is the mandibular anterior exposure sequence?
Left canine (#22), incisors, then right canine (#27), moving from patient's left to right
How many anterior and posterior placements are used in the bisecting series?
6 anterior and 8 posterior, for 14 periapical exposures
Why are premolars exposed before molars in each quadrant?
Premolar placements are easier to tolerate and less likely to evoke the gag reflex
What is the posterior quadrant sequence?
Maxillary right, mandibular right, maxillary left, then mandibular left
How is the receptor positioned for a premolar exposure?
Centered on the second premolar, with the front edge aligned with the midline of the canine
How is the receptor positioned for a molar exposure?
Centered on the second molar, with the front edge aligned with the midline of the second premolar
What are the advantages of the bisecting technique?
No beam alignment device is required, and a shorter exposure time can be used with a short PID
What is the primary disadvantage of the bisecting technique?
Dimensional distortion
Why does the bisecting technique cause image distortion?
A short PID increases beam divergence and magnification, and a 3-D tooth is projected onto a 2-D receptor so parts farther from the receptor look more elongated
Why is angulation difficult in the bisecting technique?
Without an aiming ring, it is hard to visualize the imaginary bisector, and any vertical angulation error causes elongation or foreshortening
Which technique is preferred overall, and why?
Paralleling, because the disadvantages of bisecting outweigh its advantages and paralleling gives the most accurate image with the least radiation