Comprehensive practice flashcards defining core parameters, fabrication guidelines, test procedures, and physical principles for the EENG85A single-phase transformer design project.
Turns Ratio (a)
The ratio of primary turns to secondary turns (a=N2N1=V2V1=I1I2). For the reference step-down transformer (168 turns:102 turns), the ratio is 1.647.
Turns per Volt (EN)
The fundamental design constant specifying how many turns must be wound for each volt of induced EMF, calculated as EN=4.44fBmaxAc1. For the reference design at 60Hz, it equals 14.0turns/V.

Stacking Factor (SF)
The ratio of the actual thickness of magnetic steel to the total measured stack thickness (SF=measured stack thicknessthickness of steel only), accounting for sheet insulation coating, punching burrs, and tiny air gaps (typically 0.90 to 0.95; reference design uses 0.95).
Effective Core Area (Ac)
The net cross-sectional area of magnetic material inside the coil, calculated as Ac=Wt×St×SF. For a 16mm×16mm stack with SF=0.95, it equals 243mm2 (2.43×10−4m2).

Scrapless EI Lamination
Standard-proportion transformer core stampings where two 'I' pieces fit exactly into the windows of an 'E' piece so that no steel is wasted during stamping. Key dimensions are based on tongue width Wt: outer legs and yokes are 0.5Wt, window width is 0.5Wt, window height is 1.5Wt, and overall height is 2.5Wt.
Window Fill Factor (Ku)
The fraction of the core's total window area (WA) occupied by bare copper, defined as Ku=WAN1AW1+N2AW2. For hand-wound coils, Ku should be ≤0.40 (the reference design achieves 0.35).
Current Density (J)
The current carried per unit area of bare conductor (J=AWI). A design value of J≈3A/mm2 is chosen for small transformers to ensure the coil runs warm rather than overheating.
Mean Length of Turn (MLT)
The average perimeter length of a single turn measured at the mid-depth of a winding. Because the secondary winding is wound on top of the primary, its MLT is larger (10cm compared to 8.5cm for the primary).
Area Product (Ap)
The product of the core cross-sectional area and the window area (Ap=WA×Ac), expressed in cm4, used to verify whether a given core size can support the required total volt-amperes (Pt) without exceeding thermal or winding space limits.
Transformer EMF Equation
The fundamental formula relating RMS induced voltage to frequency, turns, peak flux density, and core area: E=4.44fNBmaxAc, where the constant 4.44 originates from 22π.

Mutual Flux (Φ)
The common alternating magnetic flux (Φ=Φmaxsin(ωt)) established in the magnetic core that links both the primary and secondary coils, transferring power via Faraday's law of electromagnetic induction (e=NdtdΦ).
Secondary Overwind Factor (1.2 Multiplier)
The 20% increase applied to the ideal secondary turns calculation (N2≈1.2×V2×EN) to compensate for internal voltage drops across winding resistances and leakage reactances under full load.

Interleaving
The core assembly method of alternating the direction of E and I laminations from layer to layer (left-right, or top-bottom) to ensure joints overlap, eliminating a continuous air gap and thereby preventing high no-load current and acoustic hum.

Subtractive Polarity
The condition verified during the Polarity (dot) Test when the non-dotted ends (P2 and S2) are jumpered together, resulting in a measured voltmeter reading across dotted ends equal to the difference of the winding voltages (V3≈V1−V2≈4.9V).
Additive Polarity
The polarity outcome during a jumper test where measured voltage across the open terminals equals the sum of primary and secondary voltages (V3≈V1+V2≈19V), indicating the secondary leads are reversed relative to the expected dot convention.
V–I Method (DC Resistance Test)
A four-terminal measurement technique using an adjustable DC power supply, a DC ammeter in series, and a DC voltmeter in parallel across the winding to determine precise low winding resistances (R=IV), bypassing multimeter test-lead resistance errors.
No-Load Test (Test 3)
A bench test performed with rated AC primary voltage (12.0V) and the secondary open-circuited; it measures no-load current (I0≈0.146A) and no-load secondary voltage (V2≈7.10V) to verify core assembly quality and turns ratio.
Short-Circuit Test (Test 4)
A test where the secondary winding is directly shorted through an AC ammeter and the primary is fed through a series limiting resistor (Rlim=15Ω,10W) to safely measure short-circuit currents and primary voltage drop (Vsc) for leakage impedance calculations.
Voltage Regulation (VR)
The percentage change in secondary voltage between no-load and full-load conditions, expressed as VR=V2,FLV2,NL−V2,FL×100%. For the reference prototype, VR≈18% (7.1V down to 6.0V).
Temperature Rise by Resistance (ΔT)
The calculation of internal average winding temperature increase using the positive temperature coefficient of copper: ΔT=RcoldRhot−Rcold(234.5+Tcold). Acceptable operational limit is below 40∘C.

Coil Build / Thickness Budget
The total physical depth of all winding components (bobbin tube, wire layers, layer insulation, and wrapping) scaled by an expansion factor (1.1 for hand-wound bulge) to ensure the assembly fits within 95% of the core window width (≤7.6mm for an 8mm window).
Copper Loss (Pcu)
The I2R power dissipated as heat in the windings under load (Pcu=I12R1+I22R2). For the reference design at full load, primary copper loss is 0.53W and secondary copper loss is 0.54W, totaling 1.07W.
Core Loss (Pcore)
The power dissipated in the magnetic laminations due to hysteresis and eddy currents, independent of load current (Pcore≈0.37 to 0.45W at 1.1T and 60Hz for the reference core).
Equivalent Resistance Referred to Primary (Req)
The total winding resistance of the transformer combined and represented on the primary side: Req=R1+a2R2. For the reference prototype, Req=1.2+(1.647)2(0.54)=2.67Ω.