Industrial Electronics: Transformer Design Project

0.0(0)
Studied by 0 people
call kaiCall Kai
learnLearn
examPractice Test
spaced repetitionSpaced Repetition
heart puzzleMatch
flashcardsFlashcards
GameKnowt Play
Card Sorting

1/23

flashcard set

Earn XP

Description and Tags

Comprehensive practice flashcards defining core parameters, fabrication guidelines, test procedures, and physical principles for the EENG85A single-phase transformer design project.

24 Terms

1
New cards

Turns Ratio (aa)

The ratio of primary turns to secondary turns (a=N1N2=V1V2=I2I1a = \frac{N_1}{N_2} = \frac{V_1}{V_2} = \frac{I_2}{I_1}). For the reference step-down transformer (168 turns:102 turns168\text{ turns} : 102\text{ turns}), the ratio is 1.6471.647.

2
New cards

Turns per Volt (NE\frac{N}{E})

The fundamental design constant specifying how many turns must be wound for each volt of induced EMF, calculated as NE=14.44fBmax⁡Ac\frac{N}{E} = \frac{1}{4.44 f B_{\max} A_c}. For the reference design at 60 Hz60\,\text{Hz}, it equals 14.0 turns/V14.0\,\text{turns/V}.

3
New cards
<p>Stacking Factor ($$SF$$)</p>

Stacking Factor (SFSF)

The ratio of the actual thickness of magnetic steel to the total measured stack thickness (SF=thickness of steel onlymeasured stack thicknessSF = \frac{\text{thickness of steel only}}{\text{measured stack thickness}}), accounting for sheet insulation coating, punching burrs, and tiny air gaps (typically 0.90 to 0.950.90\text{ to }0.95; reference design uses 0.950.95).

4
New cards

Effective Core Area (AcA_c)

The net cross-sectional area of magnetic material inside the coil, calculated as Ac=Wt×St×SFA_c = W_t \times S_t \times SF. For a 16 mm×16 mm16\,\text{mm} \times 16\,\text{mm} stack with SF=0.95SF = 0.95, it equals 243 mm2243\,\text{mm}^2 (2.43×10−4 m22.43 \times 10^{-4}\,\text{m}^2).

5
New cards
<p>Scrapless EI Lamination</p>

Scrapless EI Lamination

Standard-proportion transformer core stampings where two 'I' pieces fit exactly into the windows of an 'E' piece so that no steel is wasted during stamping. Key dimensions are based on tongue width WtW_t: outer legs and yokes are 0.5Wt0.5 W_t, window width is 0.5Wt0.5 W_t, window height is 1.5Wt1.5 W_t, and overall height is 2.5Wt2.5 W_t.

6
New cards

Window Fill Factor (KuK_u)

The fraction of the core's total window area (WAW_A) occupied by bare copper, defined as Ku=N1AW1+N2AW2WAK_u = \frac{N_1 A_{W1} + N_2 A_{W2}}{W_A}. For hand-wound coils, KuK_u should be ≤0.40\le 0.40 (the reference design achieves 0.350.35).

7
New cards

Current Density (JJ)

The current carried per unit area of bare conductor (J=IAWJ = \frac{I}{A_W}). A design value of J≈3 A/mm2J \approx 3\,\text{A/mm}^2 is chosen for small transformers to ensure the coil runs warm rather than overheating.

8
New cards

Mean Length of Turn (MLTMLT)

The average perimeter length of a single turn measured at the mid-depth of a winding. Because the secondary winding is wound on top of the primary, its MLTMLT is larger (10 cm10\,\text{cm} compared to 8.5 cm8.5\,\text{cm} for the primary).

9
New cards

Area Product (ApA_p)

The product of the core cross-sectional area and the window area (Ap=WA×AcA_p = W_A \times A_c), expressed in cm4\text{cm}^4, used to verify whether a given core size can support the required total volt-amperes (PtP_t) without exceeding thermal or winding space limits.

10
New cards

Transformer EMF Equation

The fundamental formula relating RMS induced voltage to frequency, turns, peak flux density, and core area: E=4.44fNBmax⁡AcE = 4.44 f N B_{\max} A_c, where the constant 4.444.44 originates from 2π2\frac{2\pi}{\sqrt{2}}.

11
New cards
<p>Mutual Flux ($$\Phi$$)</p>

Mutual Flux (Φ\Phi)

The common alternating magnetic flux (Φ=Φmax⁡sin⁡(ωt)\Phi = \Phi_{\max} \sin(\omega t)) established in the magnetic core that links both the primary and secondary coils, transferring power via Faraday's law of electromagnetic induction (e=NdΦdte = N \frac{d\Phi}{dt}).

12
New cards

Secondary Overwind Factor (1.2 Multiplier)

The 20%20\% increase applied to the ideal secondary turns calculation (N2≈1.2×V2×NEN_2 \approx 1.2 \times V_2 \times \frac{N}{E}) to compensate for internal voltage drops across winding resistances and leakage reactances under full load.

13
New cards
<p>Interleaving</p>

Interleaving

The core assembly method of alternating the direction of E and I laminations from layer to layer (left-right, or top-bottom) to ensure joints overlap, eliminating a continuous air gap and thereby preventing high no-load current and acoustic hum.

14
New cards
<p>Subtractive Polarity</p>

Subtractive Polarity

The condition verified during the Polarity (dot) Test when the non-dotted ends (P2\text{P2} and S2\text{S2}) are jumpered together, resulting in a measured voltmeter reading across dotted ends equal to the difference of the winding voltages (V3≈V1−V2≈4.9 VV_3 \approx V_1 - V_2 \approx 4.9\,\text{V}).

15
New cards

Additive Polarity

The polarity outcome during a jumper test where measured voltage across the open terminals equals the sum of primary and secondary voltages (V3≈V1+V2≈19 VV_3 \approx V_1 + V_2 \approx 19\,\text{V}), indicating the secondary leads are reversed relative to the expected dot convention.

16
New cards

V–I Method (DC Resistance Test)

A four-terminal measurement technique using an adjustable DC power supply, a DC ammeter in series, and a DC voltmeter in parallel across the winding to determine precise low winding resistances (R=VIR = \frac{V}{I}), bypassing multimeter test-lead resistance errors.

17
New cards

No-Load Test (Test 3)

A bench test performed with rated AC primary voltage (12.0 V12.0\,\text{V}) and the secondary open-circuited; it measures no-load current (I0≈0.146 AI_0 \approx 0.146\,\text{A}) and no-load secondary voltage (V2≈7.10 VV_2 \approx 7.10\,\text{V}) to verify core assembly quality and turns ratio.

18
New cards

Short-Circuit Test (Test 4)

A test where the secondary winding is directly shorted through an AC ammeter and the primary is fed through a series limiting resistor (Rlim=15 Ω, 10 WR_{lim} = 15\,\Omega,\,10\,\text{W}) to safely measure short-circuit currents and primary voltage drop (VscV_{sc}) for leakage impedance calculations.

19
New cards

Voltage Regulation (VRVR)

The percentage change in secondary voltage between no-load and full-load conditions, expressed as VR=V2,NL−V2,FLV2,FL×100%VR = \frac{V_{2,NL} - V_{2,FL}}{V_{2,FL}} \times 100\%. For the reference prototype, VR≈18%VR \approx 18\% (7.1 V7.1\,\text{V} down to 6.0 V6.0\,\text{V}).

20
New cards

Temperature Rise by Resistance (ΔT\Delta T)

The calculation of internal average winding temperature increase using the positive temperature coefficient of copper: ΔT=Rhot−RcoldRcold(234.5+Tcold)\Delta T = \frac{R_{hot} - R_{cold}}{R_{cold}} (234.5 + T_{cold}). Acceptable operational limit is below 40 ∘C40\,^\circ\text{C}.

21
New cards
<p>Coil Build / Thickness Budget</p>

Coil Build / Thickness Budget

The total physical depth of all winding components (bobbin tube, wire layers, layer insulation, and wrapping) scaled by an expansion factor (1.11.1 for hand-wound bulge) to ensure the assembly fits within 95%95\% of the core window width (≤7.6 mm\le 7.6\,\text{mm} for an 8 mm8\,\text{mm} window).

22
New cards

Copper Loss (PcuP_{cu})

The I2R\text{I}^2\text{R} power dissipated as heat in the windings under load (Pcu=I12R1+I22R2P_{cu} = I_1^2 R_1 + I_2^2 R_2). For the reference design at full load, primary copper loss is 0.53 W0.53\,\text{W} and secondary copper loss is 0.54 W0.54\,\text{W}, totaling 1.07 W1.07\,\text{W}.

23
New cards

Core Loss (PcoreP_{core})

The power dissipated in the magnetic laminations due to hysteresis and eddy currents, independent of load current (Pcore≈0.37 to 0.45 WP_{core} \approx 0.37\text{ to }0.45\,\text{W} at 1.1 T1.1\,\text{T} and 60 Hz60\,\text{Hz} for the reference core).

24
New cards

Equivalent Resistance Referred to Primary (ReqR_{eq})

The total winding resistance of the transformer combined and represented on the primary side: Req=R1+a2R2R_{eq} = R_1 + a^2 R_2. For the reference prototype, Req=1.2+(1.647)2(0.54)=2.67 ΩR_{eq} = 1.2 + (1.647)^2(0.54) = 2.67\,\Omega.