81 Terms

1
New cards

What is the relationship between display field of view (FOV) and pixel size for a fixed matrix size?

Direct

2
New cards

A combination of rows and columns of pixels is called a what?

Matrix

3
New cards

What unit is used to measure pixel size?

Microns

4
New cards

Digital image quality is improved with what?

All options are correct

5
New cards

What happens to pixel size when matrix size increases for a fixed field of view (FOV)?

Pixel size decreases

6
New cards

What happens to spatial resolution when matrix size increases for an exposure FOV?

Spatial resolution increases

7
New cards

If display FOV is 500 mm and matrix size is 1024, what is the pixel size?

0.49 mm

8
New cards

What determines digitizing precision and the number of gray shades?

Bit depth

9
New cards

What happens to the number of gray shades when bit depth increases?

The number of shades of gray increases

10
New cards

What happens to contrast resolution when bit depth increases?

Contrast resolution increases

11
New cards

What does pixel bit depth determine in an image?

Contrast resolution

12
New cards

How many shades of gray can a 10-bit pixel display?

1024

13
New cards

What happens to contrast resolution when a system can digitize and display more gray shades?

Contrast resolution increases

14
New cards

What does greater pixel bit depth provide?

More precise digitization and more shades of gray

15
New cards

What is the number of pixels per unit area called?

Pixel density

16
New cards

What is the center-to-center distance between adjacent pixels called?

Pixel pitch

17
New cards

What improves spatial resolution?

Increased pixel density and decreased pixel pitch

18
New cards

What happens to spatial resolution when the number of line pairs per millimeter resolved increases?

Spatial resolution increases

19
New cards

What measures an imaging system’s ability to display contrast of objects varying in size?

Modulation transfer function (MTF)

20
New cards

What MTF value represents the maximum difference in brightness levels?

1.0

21
New cards

What is the range of exposures that should be used to produce a diagnostic image called?

Exposure latitude

22
New cards

What dose monitoring value measures exposure in air and estimated absorbed dose?

KAP (kerma-area product)

23
New cards

What measures the efficiency of an image receptor in converting X-ray exposure into a quality image?

Detective quantum efficiency (DQE)

24
New cards

What is the relationship between DQE and MTF?

Directly proportional

25
New cards

Which statement is true concerning computed radiography (CR) imaging plates?

All options are correct

26
New cards

What is the emission of light from a substance following stimulation by radiation called?

Luminescence

27
New cards

What is the CR phosphor layer composed of?

Barium fluorohalide with europium

28
New cards

What does the CR latent image consist of?

Electrons trapped in the phosphor layer

29
New cards

What is the emission of light when stimulated by a high-intensity laser beam called?

Photostimulable luminescence

30
New cards

What is the primary barium fluorohalide material in a CR imaging plate called?

Photostimulable phosphor

31
New cards

Which is NOT a component of a CR imaging plate?

Thin-film transistor (TFT) layer

32
New cards

In CR, which atoms become ionized when X-ray photons are absorbed by the phosphor?

Europium

33
New cards

In CR, what happens to trapped electrons?

Their number is proportional to exit exposure intensity, and they are released during readout

34
New cards

Which is NOT part of a CR reader unit?

Capacitor

35
New cards

What collects, amplifies, and converts visible light into an electrical signal?

Photomultiplier tube (PMT)

36
New cards

What scans the imaging plate in a CR reader unit?

Helium-neon laser beam

37
New cards

What is the sequence of events in a CR reader unit?

Stored energy is released as light → PMT converts light into an electrical signal → sampling and digitization

38
New cards

What happens when sampling frequency increases in CR?

Pixel density increases and sampling pitch decreases

39
New cards

What happens when sampling pitch increases in CR?

Pixel size increases and pixel resolution decreases

40
New cards

What determines how often an analog signal is reproduced in discrete digitized form?

Sampling frequency

41
New cards

What is the distance between analog points being sampled called?

Sampling pitch

42
New cards

With a fixed-matrix CR reader, what happens when a larger imaging plate is used?

Pixel size increases

43
New cards

What determines pixel bit depth?

Analog-to-digital converter (ADC)

44
New cards

Immediately before leaving the CR reader, what is the imaging plate exposed to?

Intense white light

45
New cards

Which digital imaging system converts exit radiation into electrical charges and stores them before readout?

Digital radiography (DR)

46
New cards

In DR imaging systems, where is electrical charge briefly stored?

Thin-film transistor (TFT)

47
New cards

Which array is divided into square detector elements (DELs)?

Thin-film transistor (TFT) array

48
New cards

What is the percentage of X-rays reaching a detector that are captured called?

Fill factor

49
New cards

Which is NOT a component of a direct flat-panel detector?

Phosphor layer

50
New cards

What does an indirect conversion detector use?

A scintillator and a photodetector

51
New cards

What are examples of scintillators used in indirect conversion DR?

Gadolinium oxysulfide and cesium iodide

52
New cards

What happens to X-rays in an indirect conversion DR system?

X-rays are converted to light, then to electrical charges

53
New cards

What is the sequence of direct conversion DR image production?

Exit radiation → electrical charge → TFT storage → ADC

54
New cards

What describes a detector’s ability to capture a variety of photon intensities in remnant radiation?

Dynamic range

55
New cards

What measures the efficiency of an image receptor in converting X-ray exposure into a quality image?

Detective quantum efficiency (DQE)

56
New cards

What happens to the exposure required for a quality image when DQE increases?

Required exposure decreases

57
New cards

What may result from overexposing a digital image receptor?

High signal-to-noise ratio (SNR) and increased patient exposure

58
New cards

What compares radiation exposure signal strength with image noise?

Signal-to-noise ratio (SNR)

59
New cards

What does a high SNR indicate?

High signal strength relative to noise

60
New cards

What happens to the visibility of anatomic details when SNR increases?

Visibility of anatomic details increases

61
New cards

What compares image contrast with image noise?

Contrast-to-noise ratio (CNR)

62
New cards

What happens to the visibility of anatomic details when CNR increases?

Visibility of anatomic details increases

63
New cards

What must be applied to the photoconductive detector element (DEL) surface for a DR detector to capture incoming radiation exposure?

A small electrical charge

64
New cards

According to the course answer key, what is the key distinction between CR and DR receptor technology?

DR detectors must have electrical communication with the X-ray generator (course answer; not universal)

65
New cards

What must DR detector panels be protected from?

All of the above

66
New cards

What does the size of a detector element (DEL) principally determine in DR?

Spatial resolution

67
New cards

Once data is digital, are CR and DR image processing and display the same?

True

68
New cards

Is no light produced with CR when radiation interacts with the imaging plate?

False

69
New cards

Does CR raw image data quality remain the same for up to 6 hours after exposure?

False

70
New cards

Do both CR and DR combine image capture and readout?

False

71
New cards

Does a DR system require a separate reader unit?

False — a DR system does not require a separate reader unit

72
New cards

With a flat-panel detector (FPD), are charges from each detector element (DEL) read out separately?

True

73
New cards

Is exit radiation converted to visible light in a direct conversion detector?

False

74
New cards

Do small anatomic objects have higher spatial frequency?

True

75
New cards

Does digital imaging’s large dynamic range mean significantly low exposure still produces a quality image?

False

76
New cards

Does an image with high SNR have decreased detail visibility?

False

77
New cards

Is bit depth determined by matrix size?

False

78
New cards

Is the spatial resolution of flat-panel receptors generally superior to CR?

True

79
New cards

Is DQE higher for DR compared with CR?

True

80
New cards

According to the course answer key, do all DR detectors require communication with the X-ray generator to enable data transfer following exposure?

True — course-marked answer; technically not universal

81
New cards

Is fading over time due to sensitive material the principal concern with DR images?

False