health physics is

providing radiation protection for workers and the public

2
New cards

what are the 3 categories of people health physics regards

worker

pt

public

3
New cards

health physicts can be

physician

engineer

radiation scientist

4
New cards

the dose response relationship ship is a linear

non-threshold

5
New cards

a threshold represents

amnt of dose with no response

6
New cards

health physicist do what

design equipment

caluculate and construct barriers

make protocols for alar

7
New cards

what are the three cardinal principles for radiation protection

time

distance

shielding

8
New cards

what do we wanna do to time

minimize it

9
New cards

total patient dose is what to time of exposure

directly proportional

10
New cards

how long is the reset timer in fluro

5 mins

11
New cards

what do we wanna do to distance

maximize it

12
New cards

in fluro the tech should be where in conjuction to the pt

as far as possible (they have cooties)

13
New cards

what are the three radiation sources

internal
cosmic

terrestial

14
New cards

how much HVL is 0.5mm of lead

2 HVL

15
New cards

what is HVL

amnt of AL to decrease intensity to half the og volume

16
New cards

theoretically 0.5mm of lead would decrease exposure to

25%

17
New cards

stochastic radiation response is not proportional to the dose but rather the

effective dose

18
New cards

effective dose =

actual dose x 1

19
New cards

stochastic results result from

low exposure and late effects

20
New cards

non-stochastic results from

high exposure and early response

21
New cards

what does it mean that a stochastic effect is probalistic

chance of getting the effect rather than the severity increases with the dose

22
New cards

a nonstochastic effect is based on

severity of the effect rather than the chance of getting the effect as dose increases

23
New cards

NCRP meaning

national committe on radiation protection and measurement

24
New cards

what does the tissue weighting factor state

as weight increases, radiosensitivity of organ increases

25
New cards

is the pt effective dose measured

no

26
New cards

where does the majority of occupational dose for us come from

fluro

27
New cards

the occupational exposure is approx __ of the monitored dose

10%

28
New cards

what is used for radiation risk estimation

effective dose

29
New cards

what are the three radiologic devices for terroism

RED
RDD

IND

30
New cards

RED stands for

radiation exposure device

31
New cards

RDD stands for

radiation dispersal device

32
New cards

IND stands for

Improvised nuclear device

33
New cards

RED are what

sealed sources of radioactive material

34
New cards

do RED’s disperse

no

35
New cards

Do RDD’s disperse

yes

36
New cards

The inner boundary should be established where the radiation reading is

100 mGya/hr

37
New cards

The outer boundary should be established where the radiation reading is

100 µGya/hr

38
New cards

what are radiation protection safety measures

detection, alarm, decontamination protocols, prevention of recontamination

39
New cards

what are the two protection features for both radiography and fluro

x-ray tube housing and control panel

40
New cards

the tube housing must rreduce leakage radiation to

1 mGya/hr at the distance of 1 meter

41
New cards

the SID indicator must be how accruate

within ± 2%

42
New cards

IR must be centered within how much of the actual center

1 ½ “

43
New cards

total filtration for a unit at 70+ kvp should be

2.5 mmAl

44
New cards

reproductibility states that intensity change should not exceed

5%

45
New cards

linearity states that

adjacent mA stations should produce the same intensity (no more than 10% change)

46
New cards

the operator shield prevents exposure of the tech while in the room how

by having a fixed exposure button outside the room

47
New cards

how long is the exposure switch on a mobile unit

6ft/2m

48
New cards

how many degrees should the primary beam be directed away from the tech

90

49
New cards

beam intensity at tabletop for conventional fluoro is

20 mGya/min for each mA at above 80 kVp

50
New cards

fluro intensity with no high level control

100 mGya/min

51
New cards

fluro intensity with high level control

200 mGya/min

52
New cards

Source to skin distance should not be less than what for mobile fluro

12”

53
New cards

Primary barrier for fluro

image intensifier

54
New cards

filtration for fluro

2.5mm Al equivalent

55
New cards

what type of exposure switch is used for fluro

dead mans

56
New cards

dead mans switch means what

has to be held to be on

57
New cards

bucky slot cover protects who

doctor

58
New cards

bucky slot cover is equivalent to how much lead

0.25 mm Pb

59
New cards

protective curtain protects who

doctor

60
New cards

protective curtain is how equivalent to how much lead

0.25 mm Pb

61
New cards

cumulative timer sounds when

5 mins of beam is reached

62
New cards

primary barriers protect from

primary radiation

63
New cards

secondary barriers protect from

leakage

secondary radiation

scatter

off focus radiation

64
New cards

what NCRP report dictates structural design requirements

49

65
New cards

how much lead should be in primary barrier structural design requirements by the NCRP

1/16”

66
New cards

how tall should lead walls for primary barriers in structural design requirements by the NCRP

7 ft high

67
New cards

What are behind secondary barriers

consoles

68
New cards

should you image to the console

no dumbo

69
New cards

how much lead should be in secondary barriers

1/32”

70
New cards

are there lead wall height requirements for secondary barriers

no

71
New cards

what are the 6 factors that affect barrier thickness

distance

occupancy

control

workload

use factor

kvp

72
New cards

as distance from the source to the barrier decreases what happens to barrier thickenss

increases

73
New cards

what is an example of distance for barrier thickenss

where the table and wall bucky are positioned

74
New cards

as the occupancy of an adjacent wall increases, the barrier thickness

increases

75
New cards

what classifies a controlled area

area where radiology personnel and pts are

76
New cards

what is the rate the barrier must keep for a controlled area

1 mSv/wk

77
New cards

for uncontrolled areas, the rate the barrier must keep is

20 mSv/wk

78
New cards

workload is what

amtn the machine is used

79
New cards

as workload increases the barrier thickness must

increase

80
New cards

radiation detection devices that operate in pulse mode detect what

the presence

81
New cards

radiation detection devices that operate in rate mode detect

rate expressed as mGya/hr

82
New cards

integrate mode measures

detection and measures total amnt

83
New cards

gas in the chamber of a gas filled detector is kept at a constant

voltage

84
New cards

what is measured by a gas ionization chamber

the amount of electrons liberated by x-rays

85
New cards

mesurement is proportional to what for gas ionization chambers

radiation intensity

86
New cards

if the gas chamber size increases, the sensitivity

increases

87
New cards

is the gas chamber pressure increase, the sensitivity

increases

88
New cards

for a gas filled detector, at the R region at low voltage levels when the electron is freed what occurs

electron moves to an adjacent atom and barely moves

89
New cards

the R region for gas filled detectors is called

Region of recombination

90
New cards

Do the ions migrate toward central electrode in the R region

no

91
New cards

what does the I region stand for

Ion chamber region

92
New cards

In the I region, do ions migrate toward the central electrode

yes

93
New cards

What are I region detectors used for

detection and calibration

94
New cards

What common tool in Radiography are ion chambers

AEC

95
New cards

What does the P region stand for

proportional region

96
New cards

In the P region, as voltage increases, the electrons traveling to the central electrode create

secondary electrons

97
New cards

proportional detectors can distinguish btw what

alpha and beta radiation

98
New cards

time for gas to return to original condition is

resolving time

99
New cards

scintillation means a material

emits light due to x-rays

100
New cards

scintillation detectors are coated w what on all sides except windows

polished aluminum