Electrical Power System
Consists of:
A generation subsystem which produces the electrical energy at the necessary parameters.
A distribution subsystem which provides the electrical energy to all the consumers.
The generation subsystem and distribution subsystem, are split into an AC subsystem and a DC subsystem.

DC Power Generation
Three different DC power sources:
DC battery
DC power source (external)
DC generators
Aircraft Battery Systems
Emergency power - in certain cases
APU starter motor power - for APU start.
The number of batteries depends on the amount of electrical energy that needs to be stored.

Aircraft Battery Systems (CONTINUED IMPORTANT)
The main aircraft battery is a nickel-cadmium type storage battery and is located on the battery mounting of the aircraft.
It provides 24Â VÂ DC to the DC power distribution when no other power source is available.
The External Power Unit (EPU) is a ground unit that supplies the aircraft on the ground and is sufficient as one power source for all A/C Electrical power needs on ground.
The engine-driven generators are the normal DC power source during flight. - normally starter generator

Aircraft Battery
The battery provides electrical power capable for starting the engines and provides a buffer against transient loads and generally stabilises the DC bus bar.
batteries in miniature form are used in microelectronics, particularly for volatile memory systems in computer circuits.
Batteries are of the high-performance type, with thin plates that are placed in a container filled with electrolyte material.
The container is semi-sealed and fitted with vents that allow the gases to escape but prevent spillage of the electrolyte. / they convert chemical energy into electrical energy
a flat battery depleted of electrons = This process is reversible in a secondary cell or battery.
The battery should also be as close to the main battery buses as possible. This is to minimise the use of long cable runs and the associated volt drops that may bring (They are found in Electrical service centres or avionics bay)
in emergency battery must supply at least 30Â min in cases of emergency.


Battery Venting
Rubber or other non-corrosive pipes are used as ventilation lines which terminate at points on the fuselage skin.
On lead acid types there is an acid trap fitted to catch fumes and sprays and to neutralise them. This prevents the harmful gases and vapours from being ejected onto the outer skin of the fuselage.
A non-return valve can be used to seal the ventilation system on the ground and prevent reverse airflow

Battery Connectors
Modern A/C have Quick - release battery connectors = known as ELCON CONNECTOR
provides a better connection than smaller type battery leads with terminals that fit over the battery lugs and are secured by nuts and washers.
They are of the self-locking type, but it is common practice to ensure that it does not inadvertently undo to secure using copper lockwire. (must be copper so in emergency it can be disconnected without using wire cutters because copper does not conduct)

Battery Trays
secure batteries and collect any spilt electrolyte.
Tray material is normally electrolyte proof, non-absorbent, and impact resistant. (usually reinforced plastic or metal)
When metal trays are used, they are treated with anti-corrosive paints or coated with PVC and structure around and under also treated to stop fume damage.
Batteries are securely clamped and anchored to minimise fire risk in the event.
Types of Main Batteries Fitted to Aircraft
Normally, each individual cell produces a voltage of about 1.2Â V. Because all cells are connected in series, the complete battery has a nominal voltage of 24Â V.
During Charging: the voltage of an individual cell rises to 1.5Â V.
During Discharge: the voltage drops to 1.0Â V when the cell is completely discharged.
remember is not to discharge a battery below 22Â V because this can reverse the polarity of the weakest cell in the battery. If this happens, the battery cannot be recharged in the aircraft. It must be replaced and repaired in the workshop.
The electrolyte fluid is a strong alkaline solution. Its level rises during charging, but its specific gravity is not changed. / wash with water of human skin
Within the vent cap is a valve that releases any gas overpressure, which is sometimes produced during charging.
The separator between positive and negative plates (made of plastic = separator) melts at very high temperatures, and this damages the battery. / can overheat by too many engine start attempts
NICKEL - CADMIUM:
also charge during standby and after use and must be in good condition
check battery level; only possible by monitoring the voltage and current during charging.

Maintenance
Workshop checks (base maintenance not done on A/C) for good battery condition must be carried out on average every 2000 operating hours, covering:
Storage capability
Electrolyte condition
line maintenance:
Prevent overheating: Avoid consecutive APU start attempts, as overheating lowers electrolyte levels and can melt the battery's plastic separator.
Avoid deep discharge: Never let the battery drop below 22 V, because reversing a cell's polarity prevents in-aircraft recharging and requires workshop replacement.
Monitor charge regularly: Line maintenance must check charge levels at set intervals, using voltage and current readings during charging for Ni-Cad batteries.
Charge LeveL
For nickel-cadmium batteries this is only possible, by monitoring the voltage and current during charging.
Thermal Runaway
Lead-acid batteries, whilst not immune to (TR), are much less likely to because of the amount of distilled water in the electrolyte.

Causes of Thermal Runaway
Separator damage
Unbalanced cells
Reversed cells
Internal shorts
Extreme care Required:
Incorrect electrolyte levels*
Impurities in the electrolyte, leading to internal shorts*
Loose intercell connections*
Out of tolerance charging voltages*

Constant Voltage Method
Used with lead-acid batteries.
The battery is fully charged when the current is at approx. 1Â ampere.
Multiple charging, batteries must be connected in parallel.
V = CONSTANT / I = DECREASING / R = INCREASING


Constant Current Method
Used with Ni-Cd batteries.
risk of overcharging must be monitored
It is used on Ni-Cd or new lead acid batteries, where the state of charge can be determined.
On aircraft between the DC bus bar and the battery will be a charger.
On AC powered aircraft the DC for charging the batteries will come from a Rectifier.

Testing of Batteries
Batteries must be capacity tested and require a capacity of 80%.
Calculating the Capacity
Refer to Pic

Battery Charging Systems and Charging Methods