1/25
Looks like no tags are added yet.
What is the first step before administering the Bruce protocol?
Complete preparticipation screening and confirm the participant is safe to exercise.
What should you explain before beginning the Bruce protocol?
The test procedures, RPE scale, symptoms to report, and stopping criteria.
What resting measurements should be obtained?
Resting heart rate and blood pressure before exercise.
What equipment should be prepared for the Bruce protocol?
Treadmill, heart rate monitor, blood pressure equipment, and RPE scale.
What should you explain about treadmill safety?
How to walk safely, maintain position on the belt, and report discomfort immediately.
What is the optional Bruce warm-up?
1.7 mph at 0% grade, as needed.
How long does each Bruce protocol stage last?
3 minutes.
What are the settings for Bruce Stage 1?
1.7 mph at 10% grade.
What are the settings for Bruce Stage 2?
2.5 mph at 12% grade.
What are the settings for Bruce Stage 3?
3.4 mph at 14% grade.
What are the settings for Bruce Stage 4?
4.2 mph at 16% grade.
What are the settings for Bruce Stage 5?
5.0 mph at 18% grade.
What are the settings for Bruce Stage 6?
5.5 mph at 20% grade.
What are the settings for Bruce Stage 7?
6.0 mph at 22% grade.
What measurements are recorded during every Bruce stage?
Heart rate, blood pressure, RPE, and symptoms or observations.
When should blood pressure be measured during each stage?
During the final minute of the stage.
What happens at the end of each completed stage?
Increase treadmill speed and grade to the next stage if safe to continue.
How is age-predicted maximum heart rate calculated?
220 minus age.
How is 85% of age-predicted maximum heart rate calculated?
(220 minus age) multiplied by 0.85.
When should the submaximal Bruce protocol be terminated?
At or before 85% of age-predicted maximum heart rate, or earlier for safety concerns.
What symptoms require stopping the test?
Chest pain, severe breathlessness, dizziness, poor perfusion, or other concerning symptoms.
What blood pressure response requires termination during exercise?
Systolic BP above 250 mmHg or diastolic BP above 115 mmHg, or a concerning drop in systolic BP.
What should you do immediately after terminating the test normally?
Reduce treadmill speed and grade for active recovery.
What measurements should be monitored during recovery?
Heart rate, blood pressure, RPE, and symptoms.
What specific heart rate measurement must be recorded during recovery?
One-minute recovery heart rate.
What is the complete sequence of the Bruce protocol?
Screen → Resting measurements → Setup → Warm-up if needed → Stage 1 → Monitor and advance stages → Terminate → Active recovery → Document results.