Radiographic Density
the opacity of the radiograph, also described as the amount of blackening on the film
The traditional definition of density was the degree of overall blackening from the black metallic silver deposited in the emulsion of film
Decreased
Tissue density
Decreased
Inversely proportional
Increased mAs
kVp produces scatter radiation, then scatter radiation produces fog, fog is referred as unwanted densities on the film. What happens to density?
base
What is green?

Protective layer
What is light blue?

Phosphor
What is red?

Film emulsion
What is dark blue?

Fluorescence or light photons
What is yellow?

xray photon
What is orange?

Gelatin binder
What is 1?

Silver halide crystals in suspension
What is 2?

Celluloid base
What is 3?

Physical Handling protective back coat
What is 4?

gelatin binder
Silver halide crystals in suspension
celluloid base
Physical handling back coat
What are the basic structure of film?
Amount of exposure
reaching the film determines the amount of density on the finished radiograph
View box
It is a wall-mounted or portable device with fluorescent light bulbs that is covered with white transparent material
The light can be seen coming through in some areas where less density (blackening) is present, and some areas are found with little or no density (clear/white). Little or no light will come through in areas with more density
TRUE
Information is recorded on an image that is overexposed but may not exist at all on a radiograph that is underexposed
The underexposed image has not received the information in the first place and is not capable of being manipulated to reveal details that were never recorded
If information is recorded on an image, but may not exist at all on a radiograph that is underexposed. What would be the exposure be?
Overexposed image
Overexposed Image
Whenever a choice must be made between excess and insufficient density, the wise decision is always the choice that will produce the?
Underexposed Image
If image has not received the information in the first place and is not capable of being manipulated to reveal details that were never recorded
Hot lamps
it is a high intensity viewing device used in film radiography to emit a concentrated beam of strong enough to penetrate dense, overexposed or dark areas of a processed radiograph to reveal a hidden anatomical detail
It is a device that measures the percentage of light that has been transmitted through the film.
What is the use of densitometer?
Densitometer
It differentiates the degrees of blackening being measured by
Density unit
What is the device that measures the percentage of light that has been transmitted through the film?
Brightness
describes the concept of density as it displayed on a soft-copy monitor for digital images
Window level
describes the digital processing that produces changes in density/brightness, so it also appropriate to use when controlling image density
Density
is also described as the nature of tissue
Contrast media
are high-atomic or radio-opaque substance administered to a patient to alter the absorption rate of xray photons or radiofrequency signals on the surrounding tissues
Reduction of intesity
Define attenuation?
Total absorption
What is the total energy that is fully deposited into a medium?
yes, air is a classified as a negative contrast medium, because is has a low atomic number and a low physical density relative to surrounding body tissues
Can contrast media be administered in air?
Attenuation
means a reduction in the x-ray intensity due to absorption and scattering
Areas of the beam with almost complete attenuation produce very little radiographic density and the parts of the beam with very little attenuation procude areas of greater optical density
Window glass
Transparent
Frosted glass
Translucent
Black glass
Opaque
FALSE, ATTENUATION
Remnant Radiation of the beam causes different density levels to be present on the radiograph (T or F, & correct answer if F)
Primary Controlling Factor
mAs
mAs
It is the amount of electrons hitting the anode controlled by?
X-ray Quantity
Other word of mAs?
X-ray Quality
Other word for kVp?
kVp
It is the energy of electrons hitting the anode
Directly proportional to mAs
mAs is used as the primary controller
Since density is primarily determined by the amount of exposure a receptor receives, and since exposure is _______________, _________________ of image receptor exposure and film density
30%
Minimum change necessary to cause visible shift in film density if
Double or halves
The general rule of thumb for mAs changes is to make adjustments in increments or
kVp
Focal Spot Size
Anode Heel Effect
Distance
Filtration
Beam Restriction/Collimation
Grids
Film-screens speed
Anatomy/Pathology
Film processing
what are the types of influencing factors?
Film Processing
The condition of the film processing solutions can dramatically alter film density
Thickness of the part
Tissue Density
Anatomic Number
3 Things to remember under Anatomy & Pathology
Anatomy/pathology
Because the patient is the prime attenuator of the beam, the anatomical part being examined has a great deal of influence on image receptor exposure and film density
Additive Pathology
will appear with less radiographic density
Destructive Pathology
will appear with increased radiographic density

Additive Pathology

Destructive pathology
TRUE
In Anatomy/Pathology there is a inverse relationship between tissue density and radiographic density
screen-speed/ relative speed
increases, density will increase; less exposure is needed to keep density
Relative Speed (RS) numbers
are the most useful parameters for intensifying screen combinations
Intensifying Screens
increase density on the film by intensifying the action of x-rays
Film Types
that contain increased amounts of silver halide crystals will increase density
Intensifying Screens
Relative Speed (RS) numbers
screen-speed/ relative speed
What are the film types?
ID Window
answer for 1?

cassette
answer for 2?

Screens
answer for 3?

Light-tight seal
Answer for 4?

Film
Answer for 5?

Grids
Absorbs scatter radiation
which would otherwise add exposure to the image receptor and density to the film
Scatter Clean up
Increase Contrast
Recommend to increase mAs instead
under grids: Because the primary purpose of a grid is the improvement of contrast, compensating for film density changes by varying the kVp is not recommended.
Beam Restriction/Collimation
This devices are used to restrict the beam field size and the actual area exposed on the patient
therefore, less density
As field size decrease, smaller areas are exposed and less scatter radiation.
Filtration
Filters are thin aluminum or metal devices located between the x- ray tube and beam restriction device. The purpose of filtration is to absorb the low-energy x-ray photons in the beam as they exit the tube
Air Gap Technique
OID also alters the amount of density reaching the film. This is done through the
is an alternative to the use of a radiographic grid. It purposely increases OID to allow scatter to exit the patient and not reach the image receptor
Distance
SID alters the intensity of the beam reaching the image receptor, according to the inverse square law.
Inverse square law
states that the intensity of the x-ray beam is inversely proportional to the sqaure of the distance from the source
INCREASE SID by 2
= DECREASE Density/Intensity by 4

what is the formula of inverse square law?
Positive Anode Negative Cathode
what is PANC?
Anode heel Effect
alters the intensity of radiation and therefore the density, between the anode and cathode ends of the x-ray tube. The density produced on the cathode end is more prominent
The anode heel effect may be converted to an advantage in examinations of objects with greater subject density at one end than at another.
Advantage
When the anode heel effect becomes
apparent, it can be minimized or
converted to an _____?
Focal Spot Size
Larger focal spots utilize a greater incident electron stream than small focal spots. Therefore, it requires increase mAs
Effective Focal Spot
Large
Penumbra
Increased density
what does this image shows?

Effective Focal Spot
Small
Decrease mAs
what does the image shows?

Moderate kVp
Describe the image?

High kVp
Describe the image?

Fog is increased
unwanted density on the radiograph. Its main source is scatter radiation
increase in image fog
more density
An increase in kVp also increases scatter radiation. Scatter radiation results to ______________. Image fog adds to _________ on the film
= Decrease mAs by half
Increase kVp 15%
= Increase mAs by double
Decrease kVp by 15%
Decrease by 15%
If mAs is doubled, how should kVp be changed in order to maintain the same exposure to the IR?
Increase in kVp by 15% = X2 Density (doubled)
A decrease in kVp by 15% = ½ Density (halved)
What is the 15% kVp Rules?
15 % rule
is used to predict changes in density levels with kVp
quantity
Additionally, because of the increase in energy, there is also increase in penetrability, intensity and _______?
The relationship between kVp and radiographic density is not one of proportion
kVp
Focal Spot Size
Anode Heel Effect
Distance
Filtration
Beam Restriction/Collimation
Grids
Film-screen speed
Anatomy/Pathology
film-Processing
Influencing Factors
mAs
Controlling factors
Radiographic
Tissue
Density
View box
Densitometer
Tools to help assess
Latent image formation & processing: Unexposed State
silver halide crystals reside suspended within the gelatin binder without light energy interaction
Latent image formation & processing: Exposure
Light photons from the intensifying screen interacts with the silver halide crystals in the emulsion, creating a latent image center
Latent image formation & processing: Development
Chemical processing converts the exposed silver halide crystals containing latent image centers into metallic silver grains (Ag grain), while unexposed or soluble silver complexes (soluble Ag complex) remains distinct
increased processing/Immersion time
Increased solution temperature
Faster replenishment rate
Film density increases with?
Latent image formation & processing: Fixing & Final Image
Unexposed silver halide crystals and soluble complexes are dissolved and washed away during fixing, leaving the dark metallic silver grains embedded in the gelatin