R401.3 Lot Drainage
Lots shall be graded to drain surface water away from foundation walls.
The grade shall fall a minimum of 6 inches within the first 10 feet
Table R402.2 Minimum Specified Compressive Strength of Concrete
What is the minimum specified compressive strength of basement slabs and interior slabs on grade, except garage floor slab if the weathering potential is negligible
R404.1.8 Rubble Stone Masonry
Rubble stone masonry foundation walls shall have a minimum thickness of 16 inches
R404.2.4 Backfilling
Wood foundation walls shall not be backfilled until the basement floor and first floor have been constructed or the walls have been braced
R404.3 Wood Sill Plates
Wood sill plates shall be minimum of 2-inch by 4-inch nominal lumber.
R405.2.2 Vapor Retarder
A 6-mil-thick polyethylene vapor retarder shall be applied over the porous layer with the basement floor constructed over the polyethylene.
R406.1 Concrete and Masonry Foundation Damp proofing
Masonry walls shall have not less than 3/8 inch Portland cement parking applied to the exterior of the wall.
Table R405.1
What are the drainage characteristics of Well-graded levels?
What are the draining characteristics of Silty sand?
What are the draining characteristics of Clayed gravels?
What are the drainage characteristics of inorganic clays of high plasticity, flat clays?
1507.2.6 Fasteners Roof Covering
Where the roof sheathing is less than ¾ inch thick, the nails shall penetrate through the sheathing.
Fastening for asphalt shingles shall be galvanized, stainless steel, aluminum or cooper roofing nails…
1507.2.7 Attachment
Shingles shall have the minimum number of fasteners required by the manufacturer, but not less than four fasteners per strip shingle or two fasteners per individual shingle
Where the roof slope exceeds 21 units vertical in 12 units horizontal (21:12)
Shingles shall be installed as required by manufacturer
1507.2.8 Underlayment Application
A minimum 19-inch-wide strip of underlayment felt parallel with and starting at the eaves
Fastened sufficiently to hold in place
1507.2.8.1 High Wind Attachment
Fasteners are to be applied along the overlap at a maximum spacing of 36 inches on center
1507.2.8.2 Ice Barrier
Exception: Detached accessory structures that contain no conditioned floor area
1507.2.9.1 Base and Cap Flashing
Base flashing shall be of either corrosion-resistant metal of minimum nominal 0.019 inch thickness or mineral-surfaced roll roofing weighing a minimum of 77 pound per square feet.