A comprehensive vocabulary review of magnetic quantities, units, symbols, formulas, and their electrical circuit analogs.
Magnetic Flux
The magnetic energy stored in a magnetic field, represented by the symbol Φ and measured in webers (Wb).
Weber (Wb)
The unit of measurement for magnetic flux; 1 weber=1×108 flux lines.
Formula for Magnetic Flux (Φ)
Φ=RmFm, where Fm is magnetomotive force in ampere turns (A.T) and Rm is magnetic reluctance in ampere turns per weber (A.T/Wb).
Magnetomotive Force (mmf)
The force that creates magnetic flux lines, denoted by the symbol Fm and measured in ampere turns (A.T).
Formulas for Magnetomotive Force (Fm)
Fm=I×N and Fm=Φ×Rm, where I is current in amps, N is number of turns, Φ is flux in webers, and Rm is reluctance in ampere turns per weber.
Magnetic Reluctance
The opposition to the flow of flux lines in a magnetic circuit, denoted by the quantity symbol Rm and measured in ampere turns per weber (A.T/Wb).
Formula for Magnetic Reluctance (Rm)
Rm=ΦFm, where Fm is magnetomotive force in ampere turns (A.T) and Φ is magnetic flux in webers (Wb).
Relative Permeability (μr)
A dimensionless coefficient factor by which a substance is more permeable than air, having no units of measurement and no formula (e.g., steel with μr=2000 can establish 2000 more flux lines than air).
Magnetic Field Intensity (H)
The magnetic force acting on a specific length of a magnetic circuit, with the unit of ampere turns per meter (A.T/m).
Formula for Magnetic Field Intensity (H)
H=mFm, where Fm is magnetomotive force in ampere turns (A.T) and m is length in meters.
Magnetic Analog of Voltage
Magnetomotive Force, measured in Ampere Turns (A.T), which serves as the magnetic circuit counterpart to voltage in volts (V).
Magnetic Analog of Current
Magnetic Flux, measured in Webers (Wb), which serves as the magnetic circuit counterpart to current in amps (A).
Magnetic Analog of Resistance
Reluctance, measured in Ampere-turns/Weber (A.T/Wb), which serves as the magnetic circuit counterpart to electrical resistance in ohms (Ω).
Magnetic Analog of Conductivity
Permeability, measured in Weber's/ Ampere-Turns, which serves as the magnetic circuit counterpart to electrical conductivity in Siemens/meter (s).