How can you make a room feel more compact and cozier?
Use stronger/darker colors on walls to absorb natural light
Which lighting position is most likely to create a more formal atmosphere?
Lights above eye level
Which of the following best describes a color temperature of 2700K?
Warm white glow, suitable for homes and restaurants
Which of the following best describes light trespass?
Light falling where it is not intended or needed
Which design strategy is best to enlarge the perception of space in a room?
Use light colors that reflect natural light
During which design phases do lighting designers most actively contribute according
to the design process shown?
Design Development Phase (Phase 3) and Construction Administration Phase (Phase 6)
Which of the following is NOT listed as a factor influencing visual comfort?
Indoor air humidity
What are the primary colors for light?
Red, Green, Blue
Which statement about the Color Rendering Index (CRI) is correct?
Incandescent and halogen lamps typically have a CRI of 100
Which of the following is NOT typically included in the Ownerâs Project Requirements
(OPR) for visual comfort?
High indoor temperature
Which of the following statements about operating temperature of LEDs is correct?
Excessive heat reduces LED lifespan and efficiency
What does luminous efficacy measure?
The efficiency of a light source in lumens per watt
What instrument is commonly used to measure visual comfort in buildings?
Lux meter
What does dimming (dimmability) primarily achieve in lighting design?
Operates lamps at less than full intensity for energy savings or mood creation
In Task 3 (Design Development Phase), which of the following is a key responsibility of
the lighting designer?
Selecting light sources and luminaires for the project
During the Execute Design stage, which of the following is included under Lighting
Design tasks?
Create reflected ceiling plans
What must be measured first in order to assess glare?
Luminance
Which of the following is an example of a primary light source?
Candle
Which of the following is a key task under Illuminance Calculations when selecting and
confirming lighting equipment?
Confirm and meet light levels for visual tasks
Which type of lamp generally has an instant starting time at full brightness?
LED lights
DF stands for?
Daylight Factor
SC stands for?`
Sky Component
ERC stands for?
Externally reflected component
IRC stands for?
Internally reflected component
SHGC stands for?
Solar heat gain coefficient
Diameter of lamp formula?
PAR# = #/8 inches
What are the two types of angles used to measure light source intensity with percentage of the center beam?
Field Angle w/ 10% center and Beam Angle w/ 50% center
What best describes Direct Distribution lighting?
All of the light is directed into the occupied area of the room
Which type of lighting serves as the basic source of illumination for an entire room?
Ambient lighting
Task lighting is best used in which of the following scenarios?
Illuminating a kitchen work surface
What is an example of accent lighting?
Track lighting
During which design phase should building form, orientation, layout, and major apertures be considered for daylighting
Conceptual design phase
According to IESNA RP-5-99, what is an essential ingredient for daylighting design?
Zone electric lighting for daylight-responsive control
what is the primary concept of top lighting in daylighting design?
Capture diffuse daylight and avoid direct solar gain
Which glazing tech is designed to reduce infrared heat gain while allowing visible light transmission?
Low-Emissivity (Low-E) glazing
What are the three main components of Daylight Factor?
Sky Component, Externally reflected component, Internally reflected component
What is correct about the Internally Reflected Component is correct?
It is subdivided into reflected skylight (IRC) and reflected ground light (IRC2)
According to Well v1 standard and ASHRAE/IES recommendations, walls should have a reflectance of at lease?
70%
In the zonal cavity method, where is the room cavity located
between the luminary plane and the work plane
A luminaire has a largest dimension of 0.80 m and the calculation point is 3.0 m away. Based on the point method 1/5 rule, what is correct?
The point method is not valid because the max permitted source dimension is 0.60 m.
What best describes the Lumen Method(Zonal Cavity Method)?
It estimates average illuminance for a uniform lighting system and can be used to determine the required number of fixtures
Which of the following statements about lighting quantities and units is correct
Lux and footcandle both measure illuminance
What are the two methods introsuced for illuminance calculations
Point method and Lumen method
For the point method when calculation point is not on the centerline of the luminare beam, which intensity should be used?
The directional intensity I0 from the candela table or candlepower distribution curve
Which statement best compares switches and dimmers as basic lighting control?
Switches provide binary on/off control, while dimmers allow fine-tuning of light levels.
What is a limitation of manual lighting control initiation