All Presentation Review AREN 320

0.0(0)
Studied by 2 people
call kaiCall Kai
learnLearn
examPractice Test
spaced repetitionSpaced Repetition
heart puzzleMatch
flashcardsFlashcards
GameKnowt Play
Card Sorting

1/69

encourage image

There's no tags or description

Looks like no tags are added yet.

70 Terms

1
New cards

How can you make a room feel more compact and cozier?

Use stronger/darker colors on walls to absorb natural light

2
New cards

Which lighting position is most likely to create a more formal atmosphere?

Lights above eye level

3
New cards

Which of the following best describes a color temperature of 2700K?

Warm white glow, suitable for homes and restaurants

4
New cards

Which of the following best describes light trespass?

Light falling where it is not intended or needed

5
New cards

Which design strategy is best to enlarge the perception of space in a room?

Use light colors that reflect natural light

6
New cards

During which design phases do lighting designers most actively contribute according
to the design process shown?

Design Development Phase (Phase 3) and Construction Administration Phase (Phase 6)

7
New cards

Which of the following is NOT listed as a factor influencing visual comfort?


Indoor air humidity

8
New cards

What are the primary colors for light?

Red, Green, Blue

9
New cards

Which statement about the Color Rendering Index (CRI) is correct?

Incandescent and halogen lamps typically have a CRI of 100

10
New cards

Which of the following is NOT typically included in the Owner’s Project Requirements
(OPR) for visual comfort?

High indoor temperature

11
New cards

Which of the following statements about operating temperature of LEDs is correct?

Excessive heat reduces LED lifespan and efficiency

12
New cards

What does luminous efficacy measure?

The efficiency of a light source in lumens per watt

13
New cards

What instrument is commonly used to measure visual comfort in buildings?

Lux meter

14
New cards

What does dimming (dimmability) primarily achieve in lighting design?

Operates lamps at less than full intensity for energy savings or mood creation

15
New cards

In Task 3 (Design Development Phase), which of the following is a key responsibility of
the lighting designer?


Selecting light sources and luminaires for the project

16
New cards

During the Execute Design stage, which of the following is included under Lighting
Design tasks?


Create reflected ceiling plans

17
New cards

What must be measured first in order to assess glare?

Luminance

18
New cards

Which of the following is an example of a primary light source?

Candle

19
New cards

Which of the following is a key task under Illuminance Calculations when selecting and
confirming lighting equipment?

Confirm and meet light levels for visual tasks

20
New cards

Which type of lamp generally has an instant starting time at full brightness?

LED lights

21
New cards

DF stands for?

Daylight Factor

22
New cards

SC stands for?`

Sky Component

23
New cards

ERC stands for?

Externally reflected component

24
New cards

IRC stands for?

Internally reflected component

25
New cards

SHGC stands for?

Solar heat gain coefficient

26
New cards

Diameter of lamp formula?

PAR# = #/8 inches

27
New cards

What are the two types of angles used to measure light source intensity with percentage of the center beam?

Field Angle w/ 10% center and Beam Angle w/ 50% center

28
New cards

What best describes Direct Distribution lighting?

All of the light is directed into the occupied area of the room

29
New cards

Which type of lighting serves as the basic source of illumination for an entire room?

Ambient lighting

30
New cards

Task lighting is best used in which of the following scenarios?

Illuminating a kitchen work surface

31
New cards

What is an example of accent lighting?

Track lighting

32
New cards

During which design phase should building form, orientation, layout, and major apertures be considered for daylighting

Conceptual design phase

33
New cards

According to IESNA RP-5-99, what is an essential ingredient for daylighting design?

Zone electric lighting for daylight-responsive control

34
New cards

what is the primary concept of top lighting in daylighting design?

Capture diffuse daylight and avoid direct solar gain

35
New cards

Which glazing tech is designed to reduce infrared heat gain while allowing visible light transmission?

Low-Emissivity (Low-E) glazing

36
New cards

What are the three main components of Daylight Factor?

Sky Component, Externally reflected component, Internally reflected component

37
New cards

What is correct about the Internally Reflected Component is correct?

It is subdivided into reflected skylight (IRC) and reflected ground light (IRC2)

38
New cards

According to Well v1 standard and ASHRAE/IES recommendations, walls should have a reflectance of at lease?

70%

39
New cards

In the zonal cavity method, where is the room cavity located

between the luminary plane and the work plane

40
New cards

A luminaire has a largest dimension of 0.80 m and the calculation point is 3.0 m away. Based on the point method 1/5 rule, what is correct?

The point method is not valid because the max permitted source dimension is 0.60 m.

41
New cards

What best describes the Lumen Method(Zonal Cavity Method)?

It estimates average illuminance for a uniform lighting system and can be used to determine the required number of fixtures

42
New cards

Which of the following statements about lighting quantities and units is correct

Lux and footcandle both measure illuminance

43
New cards

What are the two methods introsuced for illuminance calculations

Point method and Lumen method

44
New cards

For the point method when calculation point is not on the centerline of the luminare beam, which intensity should be used?

The directional intensity I0 from the candela table or candlepower distribution curve

45
New cards

Which statement best compares switches and dimmers as basic lighting control?

Switches provide binary on/off control, while dimmers allow fine-tuning of light levels.

46
New cards

What is a limitation of manual lighting control initiation

47
New cards
48
New cards
49
New cards
50
New cards
51
New cards
52
New cards
53
New cards
54
New cards
55
New cards
56
New cards
57
New cards
58
New cards
59
New cards
60
New cards
61
New cards
62
New cards
63
New cards
64
New cards
65
New cards
66
New cards
67
New cards
68
New cards
69
New cards
70
New cards