treatment parameters
1) stage of healing
2) aims of treatment
ERA
frequency
mode
intensity/dosage
duration
determine aims of Tx (3)
identify stage of healing
determine outcome measures: ie dec pain, inc ROM etc
thermal or non thermal effects
mode: continuous
mild to moderate warmth
should not be painful
mode: pulsed
no cutaneous sensations (no heating!)
should not be painful
frequency: superficial (2-3 cm)
3 MHz
i..e PF, achilles tendinitis, epicondylitis
frequency: deep (> 3cm in depth)
1 MHz
i.e soleus, piriformis, hip adductors
Tx duration
general guideline: 5-8 mins (> time if using 1 MHZ or for thermal effects)
depends on desired temp inc, size of area to be treated, goals of Tx, duty cycle
size of Tx area
no larger than 2-3 x the size of the ERA of the crystal
if larger area divide area into separate Tx, whirpools, hot packs etc
intensity/dosage
no definitive guidelines
use the lowest intensity possible to achieve the desired therapeutic effect
dosage considerations must account for (4)
tissue type - organized collagen absorbs more u/s than ms
boney reflection?
coupling - gel/water
depth of lesion - frequency
muscle recommended dosages: superficial
3.0 MHZ @ 0.8-1.5 w/cm2
muscle recommended dosages: deep
1 MHz @ 0.8-2.0 w/cm2
tendon/lig/capsule recommended dosages: superficial
3 MHz @ 0.3-0.5 w/cm2
tendon/lig/capsule recommended dosages: deep
1 MHz @ 0.4-1.5 w/cm2
calibration
units should be calibrates at least 1x/year
output frequency, ERA & date of last calibration should be recorded on the generator or the transducer
application techniques (4)
direct contact
immersion
gel pad
phonophoresis
coupling media def
facilitates the transmission of u/s energy by dec impedance at the air-skin interface
3 types of coupling media
gel (direct appli)
water (immersion)
gel pads (bony prominences)
ultrasound gel (3)
most commonly used coupling medium
composed of distilled water and a non reflective material
minimizes the air b/w the sound head and the tissue
immersion technique
recommended if area to be treated is smaller than the diameter of the sound head OR if Tx area is irregular (bony prominences)
tap vs degassed water
for thermal effects water must be body core temp (37 degrees(
plastic, ceramic or rubber basins are favoured over metal basins (reflection)
gel pads
for irregular tx area (i.e lat malleolus or knuckles)
apply a thin layer of gel on both sides of gel pad
bottom layer ensures no air is trapped b/w bony prominence
contraindications for ultrasound (13)
do not use thermal effects to treat an acute injury
cancer
infection
open wounds
pregnancy
cardiac pacemaker or implanted neurostimulation device
deep vein thrombosis
impaired circulation
impaired sensation
hemorrhagic conditions
TB
over eyes, anterior neck, carotid sinus and reproductive organs
over pelvis during menstruation
ultrasound precautions (4)
plastic or metal implants
active epiphysis (growth plate)
if pain is reported dec u/s intensity
if no improvement after ~14 Tx, consider other modalities or change parameters
application precautions
never inc intensity on the ultrasound unit until the sound head has coupling media and head if against the skin surface
application precautions: periosteal pain (3)
move sound head faster
dec duty cycle
dec intensity
treatment schedule: inflammatory
treat every other day
pulsed 20% duty cycle
treatment schedule: proliferation/maturation
treat daily
low intensity conditions
treatment schedule: chronic condition
treat daily
medium and high intensity @ continuous setting
stretch window def
window of opportunity of vigorous heating when tissue undergo the greatest extensibility and elongation
5-10 window only
to inc duration the joint may be placed on stretch during the last 2-3 mins of application
phonophoresis def
use of u/s to move a topical medication into the tissues