Pneumatic systems
used for mechanical or thermal (de-icing etc)
power / air sources:
Engines
Auxiliary Power Units (APU)
Ground Air Power Units
no return lines are required or temp issues

Vacuum System
can be classed as an alternative source of air.
In the ‘main’ position, the vacuum gauge indicates the vacuum in the lines of the artificial horizons and directional gyro.
In the other positions, the lower value of the vacuum for the turn and bank (T&B) indicators is displayed.
Low - Pressure System
A supply of warm low-pressure air (approximately 1-10 psi) is essential for the operation of certain systems, such as anti-icing the leading edge of the wing or horizontal stabiliser. The air can come from either the engine or the APU.
A thermal switch is incorporated into the system to prevent overheating and close the valve.

Medium - Pressure System
operates at a pressure between 50-150 psi and draws air from the compressor section of a turbine engine.
operates using bleed air to provide pneumatic power for engine starts
can also provide hydraulic power to the aircraft systems if the hydraulic system is equipped with an Air-driven Hydraulic Pump (ADP).

High - Pressure System
pressures between 1000-3000 psi
air bottle within has two control valves - one for charging - one for shut off

Safety Precautions
Ensure pneumatic system is fully depressurised before working on it
engine components ensure they cool down before working on them
A/C Cross bleed system
page 158 read section to understand it

Engine Bleed Air
pressurised air can be bled off from the engine compressor in:
Low-Pressure (LP) bleed port (some twin-shaft engines)
Immediate-Pressure (IP) bleed port (triple-shaft engines)
High-Pressure (HP) bleed port
The choice of bleed port depends on engine speed, which influences the compressor stage.
LP or IP air is used during take-off, climb, and cruise.
HP bleed air is used whenever the LP or IP air supply is inadequate

compressor
roots type blower
Reciprocating Air Compressor
two cylinders - one is large in diameter and one is small in diameter
large one is pulling in air small one is further compressing check pic
pistons are driven by a common crankshaft to transfer high-pressure gases into and out of the cylinders.

Rotary Air Compressor
operate by trapping air between two meshed rotors and reducing the volume of the trapped air as it moves down through them.
This reduction in volume produces compressed air.
male and female rotors rotate in opposite directions, they draw air in between them.

Differences Between Centrifugal and Axial Air Compressors
Centrifugal Compressor - Not suitable for multi-staging.
Axial Compressor - Suitable for multi-staging.
Roots Type Blower
Pressure builds up because the blower can deliver more air than the system can use.
Dry Pumps
The vanes and rotor are self-lubricating, so no oil needs to be supplied to the vane contact area.
Wet Pumps
we need oil for them
Pressure Relief Valves (PRV)
prevent excessive pressures from rupturing pressure lines and blowing out seals.
Check Valve
This type of check valve is called a one-direction flow control valve.
Restrictor Valve
The restrictor valve reduces the volume of airflow, and airspeed, delivered to the user system.
The outlet port reduces the rate of airflow and the speed of operation to the user system.
Filters
Any accumulated moisture or fluid falls to the bottom of the filter housing and requires periodic draining.
Desiccant/Moisture Separator
Always located downstream (output) of the compressor. Its purpose is to remove any moisture created by the compressor.
consists of a reservoir, a pressure switch, a dump valve, and a check valve.

Chemical Drier
various locations in a pneumatic system.
purpose is to absorb any moisture that collects in the lines and other parts of the system.
Each drier contains a cartridge that should be blue in colour. If not, this means the cartridge is contaminated with moisture and should be replaced.
Pressurisation with Engine Air
the cross-bleed or isolation valves are electrically controlled and pneumatically actuated, with a failsafe to the closed position.
Pressurisation with External Air Supply
Whenever the aircraft is supplied with air, at least one window or door must be open to prevent accidental cabin pressurisation.
Duct Temperature Regulation (high)
Cooling air (fan air) is taken from the engine fan duct. The cooling effect depends on the mass and temperature of the fan air.
If the pre-cooler outlet temperature increases above a predetermined value, a condition known as ‘over-temperature’ occurs. A thermostat is used to monitor the temperature; it is located downstream of the pre-cooler.
When the downstream temperature is too high, the thermostat opens an ambient bleed port, causing the bleed valve to close if necessary.
The bleed valve is located upstream of the pre-cooler to control over temperature.
Fan Air Valve (FAV)
pneumatically operated butterfly-type valve with a manual override to the fully open position – its fail-safe position.
The higher the temperature becomes, the wider the FAV opens + vice versa
Leak Detection
If a leak occurs in an air duct, it causes overheating. This is monitored by overheat detection sensors located along the length of the ducts.
In response to the leak, the affected engine bleed air system is shut off to isolate the issue. This can happen automatically, via the pneumatic controller, or manually, depending on the aircraft system.
Indication
The engine bleed valve automatically closes when the bleed air temperature exceeds approximately 254℃ (490℉).
Engine Starting
A Starter Air Valve (SAV) is connected to each engine. At approximately 64% rpm the starter valve is commanded to close, confirming the engine is running.
Wing Anti‑ice (WAI)
ice detector monitors the outside air temperature. When the temperature drops below 10℃ (50℉), the WAI valves are commanded to open and supply warm bleed air to the leading edges.
The WAI valves can be manually controlled from the flight deck.