Carotid Artery Pathology and Diagnosis (M4U2)

0.0(0)
Studied by 0 people
call kaiCall Kai
learnLearn
examPractice Test
spaced repetitionSpaced Repetition
heart puzzleMatch
flashcardsFlashcards
GameKnowt Play
Card Sorting

1/42

encourage image

There's no tags or description

Looks like no tags are added yet.

43 Terms

1
New cards

What is the DR measurement?

Diameter reduction measurement - used more w/ CTA, MRA, and DSA (but can be used in U/S)

[(A - B)/A] (100)

A = normal lumen diameter

B = stenosis diameter

2
New cards

How is a DR measurement done with U/S?

- Done w/ 2D B-mode or CD/PD in the sagittal plane, placing calipers INNER to INNER

[(A - B)/A] (100)

A = normal lumen diameter

B = stenosis diameter

3
New cards

TRUE or FALSE: DR measurements via U/S are done with placing calipers inner to inner.

TRUE: A DR measurement is to measure the lumen size

4
New cards

What are the limitations of ultrasound for a carotid DR measurement? (HINT: 3)

- May have limited vis of lumen border (ex. calcs, reverb, poor window)

- Obtaining an optimal sagittal measurement is tricky

- CD/PD limitations (ex. bleeding, power over-estimates lumen sizes)

5
New cards

What is an AR measurement?

Area reduction measurement (less common than DR)

- Measure size of lumen with athero, then measure residual patent lumen

- Good for non-concentric narrowing

- Done in TRANS plane at most narrowed portion of stenosis

6
New cards

TRUE or FALSE: AR and DR are equivalent.

FALSE: AR and DR are NOT equivalent.

7
New cards

What is a filling defect?

Lack of colour filling (usually due to athero)

8
New cards

What does the "jet" refer to?

Area within or just beyond a stenosis with the highest velocities

(this is where you should take a PW spectral doppler tracing)

9
New cards

When is the mosaic pattern seen?

Post stenotic turbulence - reversal of flow and aliasing seen together to make a mosaic pattern

10
New cards

What is a CD bruit?

High grade stenosis can cause tissue vibrations, leading to a speckled pattern that shows flow outside the vessel (similar to turning up CD gains too high)

11
New cards

What is power Doppler used for?

Detection of very slow flow such as string/trickle flow

12
New cards

What are the advantages of power Doppler? (HINT: 2)

- Detects presence of flow (in vessels w/ very slow flow)

- No angle dependency

13
New cards

What is an ICA stenosis diagnosis based off of? (HINT: 3)

PSV, EDV, and ratio

14
New cards

TRUE or FALSE: Tardus parvus can be seen in a 50% stenosis.

FALSE: Tardus parvus (dampened waveform) is only seen in higher grade stenosis (85% or more)

15
New cards

What parameter is the first to rise in a stenosis? PSV or EDV?

PSV (it is the sonographer's job to find the highest velocity at the jet)

16
New cards

How is a PSV ratio calculated for an ICA stenosis?

ICA stenosis PSV / CCA PSV = ratio

(inc ratio = inc severity of stenosis)

17
New cards

TRUE or FALSE: Proximal to a high grade stenosis will display a low resistance waveform.

FALSE: Proximal to a high grade stenosis will display a HIGH resistance waveform (decreased diastolic flow), increasing pulsatility.

18
New cards

What PSV and EDV generally qualifies as a 50-69% (moderate) ICA stenosis?

- PSV = 180-230 cm/s

- EDV = 40-100 cm/s

19
New cards

What is the exception to the 50-69% ICA stenosis rule?

The general rule is that the PSV is at least 180cm/s to be considered a 50-69% stenosis

However, if an ICA stenosis is less than 180cm/s but over 125cm/s and displays a PSV ratio of 2.0-4.0, then it is considered a 50-69% ICA stenosis.

20
New cards

Why are stenoses categorized into severe, moderate, and mild?

Drive treatment decisions (aggressive vs conservative)

21
New cards

What are the treatment decisions for a severe stenosis (over 70%)?

- M/c surgery is done to prevent a CVA

- May also use conservative treatment (ex. medication) in conjunction w/ surgery

22
New cards

What are the treatment decisions for a moderate stenosis (50-69%)?

- Physicians decide if stenosis would benefit from surgery or not (discretionary surgery)

- More so conservative treatment

23
New cards

What are the treatment decisions for a mild stenosis (less than 50%)?

Conservative

24
New cards

Where are ECA stenosis typically located?

Origin/proximal segments

25
New cards

What are the main criteria when assessing ECA stenosis? (HINT: 2)

- PSV over 180cm/s = 50-99% stenosis

- Ratio: ECA PSV/CCA PSV = 2.0 or higher = 50-99% stenosis

(ratios may or may not be used)

26
New cards

Why is there little concern with an ECA stenosis?

B/c ECA doesn't give rise to a TIA

27
New cards

What does an ECA stenosis waveform look like?

- Focal velocity increases

- Dampened distal waveform

- Displays poststenotic turbulence

28
New cards

How are CCA stenoses classified? What measurment is used to obtain this classification?

More than 50% or less than 50%

(use a ratio - CCA stenosis/ CCA prox to stenosis = 2.0 or higher = over 50%)

29
New cards

TRUE or FALSE: For an ICA with trickle flow, a PSV ratio is obtained to determine the percent stenosis.

FALSE: Instead of the jet type of velocity seen in a stenosis, a lower velocity w/ a somewhat higher resistance is seen. Therefore, PSV, EDV, and ratios no longer apply, as they can be variable.

30
New cards

TRUE or FALSE: A complete ICA occlusion is treated via TLD/stenting.

FALSE: Once there is a complete ICA occlusion, direct intervention (TLD/stenting, CEA) are NO longer possible.

31
New cards

What do chronic occlusions of the ICA result in?

Hypoplastic ICA

32
New cards

How is compensatory hemodynamics seen in the ICA?

A higher than normal PSV and EDV is seen in the contralateral CCA and ICA to make up for the occlusion in the ICA on the opposite side.

33
New cards

What clues are there to determine an ICA occlusion? (HINT: 3)

- Flow proximal to occlusion has high pulsatility

- Contralateral CCA and ICA have higher PSV and EDV to make up for occluded ICA (compensatory hemodynamics)

- Ipsilateral ECA changes to low resistant for collaterals to kick in (internalization of the ECA)

34
New cards

What is internalization of the ECA?

When the ipsilateral ICA is occluded, the ECA changes from a moderate resistant to low resistant vessel, as the ECA collaterals kick in to make up for the occlusion

35
New cards

What is the thump artifact?

- Artifact on spectral doppler trace to indicate occluded vessel

(DON'T MIX THIS W/ TRICKLE FLOW)

36
New cards

What is the blood flow like during a CCA occlusion?

CCA is occluded from proximal to distal, leading to branches of the ECA will reverse their flow into the ICA

37
New cards

What does the waveform of the ECA and ICA look like during a CCA occlusion?

- ICA = antegrade, dampened flow

- ECA = retrograde flow

38
New cards

How does blood flow during a BCA stenosis? What do spectral tracings look like for the vessels involved?

- CCA and ICA steal blood from rt vertebral, rt subclavian, and even rt CCA (flow reversal from rt S/C, vertebral, CCA)

- None of the vessels display normal flow

39
New cards

What is a root stenosis? What does the spectral trace for this condition look like?

- Stenosis of aortic valve (start of systemic blood circulation)

- Bilateral dampened flow form carotids, S/C, and vertebrals

- Possibly low brachial systolic pressures bilaterally

40
New cards

What is aortic valve insufficiency?

Aortic valve fails to close properly resulting in some retrograde flow (regurgitation)

41
New cards

A waveform displays a double peaked systole. What condition is this indicative of?

Aortic valve insufficiency

42
New cards

Why is it important to recognize atrial fibrillation?

A-fib leads to increased risk of thrombus in the left atria, which could lead to stroke/TIA

43
New cards

TRUE or FALSE: Diagnosis of an ICA stenosis via U/S becomes difficult when someone has low cardiac output.

TRUE